Dosimetrical evaluation of Leksell Gamma Knife 4C radiosurgery unit

被引:0
|
作者
Sajeev, Thomas [1 ,2 ]
Mustafa, Mohamed M. [2 ]
Supe, Sanjay S. [3 ]
机构
[1] Deemed Univ, Natl Inst Mental Hlth & Neuro Sci, Dept Neurosurg, Bangalore, Karnataka, India
[2] Univ Calicut, Dept Phys, Kozhikode, Kerala, India
[3] Kidwai Mem Inst Oncol, Dept Radiat Phys, Banaglore, India
关键词
Gamma knife; radiosurgery; dosimetry; Leksell; stereotactic; accuracy;
D O I
10.2478/v10013-011-0011-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A number of experiments was performed using standard protocols, in order to evaluate the dosimetric accuracy of Leksell Gamma Knife 4C unit. Verification of the beam alignment has been performed for all collimators using solid plastic head phantom and Gafchromic TM type MD-55 films. The study showed a good agreement of Leksell Gammaplan calculated dose profiles with experimentally determined profiles in all three axes. Isocentric accuracy is verified using a specially machined cylindrical aluminium film holder tool made with very narrow geometric tolerances aligned between trunnions of 4 mm collimator. Considering all uncertainties in all three dimensions, the estimated accuracy of the unit was 0.1 mm. Dose rate at the centre point of the unit has been determined according to the IAEA, TRS-398 protocol, using Unidose-E (PTW-Freiburg, Germany) with a 0.125 cc ion chamber, over a period of 6 years. The study showed that the Leksell Gamma Knife 4C unit is excellent radiosurgical equipment with high accuracy and precision, which makes it possible to deliver larger doses of radiation, within the limits defined by national and international guidelines, applicable for stereotactic radiosurgery procedures.
引用
收藏
页码:105 / 120
页数:16
相关论文
共 50 条
  • [1] Dosimetric comparison of the Leksell Gamma Knife Perfexion and 4C
    Novotny, Josef, Jr.
    Bhatnagar, Jagdish P.
    Niranjan, Ajay
    Quader, Mubina A.
    Huq, M. Saiful
    Bednarz, Greg
    Flickinger, John C.
    Kondziolka, Douglas
    Lunsford, L. Dade
    JOURNAL OF NEUROSURGERY, 2008, 109 : 8 - 14
  • [2] Evaluation and validation of the convolution algorithm for Leksell Gamma knife radiosurgery
    Dubus, Francois
    Talbot, Antoine
    Maurice, Jean-Baptiste
    Devos, Laura
    Reyns, Nicolas
    Vermandel, Maximilien
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (15):
  • [3] Leksell gamma knife radiosurgery for trigeminal schwannoma
    Hynkova, M.
    Liscak, R.
    Urgosik, D.
    Vymazal, J.
    CESKA A SLOVENSKA NEUROLOGIE A NEUROCHIRURGIE, 2007, 70 (02) : 178 - 185
  • [4] Evaluation of the stability of the stereotactic Leksell Frame G in Gamma Knife radiosurgery
    Rojas-Villabona, Alvaro
    Miszkiel, Katherine
    Kitchen, Neil
    Jaeger, Rolf
    Paddick, Ian
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (03): : 75 - 89
  • [5] Efficiency and Dose Planning Comparisons between the Perfexion and 4C Leksell Gamma Knife Units
    Niranjan, Ajay
    Novotny, Josef, Jr.
    Bhatnagar, Jagdish
    Flickinger, John C.
    Kondziolka, Douglas
    Lunsford, L. Dade
    STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2009, 87 (03) : 191 - 198
  • [6] Diagrams for the Leksell Gamma Knife 4C automatic positioning system accessible shot coordinates
    Watanabe Y.
    Radiological Physics and Technology, 2013, 6 (1) : 197 - 201
  • [7] RADIOSURGERY WITH THE WORLD'S FIRST FULLY ROBOTIZED LEKSELL GAMMA KNIFE PERFEXION IN CLINICAL USE: A 200-PATIENT PROSPECTIVE, RANDOMIZED, CONTROLLED COMPARISON WITH THE GAMMA KNIFE 4C
    Regis, Jean
    Tamura, Manabu
    Guillot, Cecile
    Yomo, Shoji
    Muraciolle, Xavier
    Nagaje, Mariko
    Arka, Yasser
    Porcheron, Denis
    NEUROSURGERY, 2009, 64 (02) : 346 - 355
  • [8] Assessment of the accuracy in ophthalmic radiosurgery with the Leksell Gamma Knife
    Novotny, J
    Novotny, J
    Liscak, R
    Spevacek, V
    Hrbacek, J
    Dvorak, P
    Cechak, T
    Schmitt, M
    Tlachacova, D
    Tintera, J
    Vymazal, J
    Vladyka, V
    MEDICAL PHYSICS, 2004, 31 (06) : 1865 - 1865
  • [9] System accuracy of Leksell Gamma Knife stereotactic radiosurgery
    Yu, C.
    Pagnini, P.
    Giannotta, S.
    Apuzzo, M.
    MEDICAL PHYSICS, 2007, 34 (06) : 2492 - 2492
  • [10] An open ceiling radiosurgery vault for the practical source reloading of the leksell Gamma Knife unit
    Kalend, A
    Bhatnagar, J
    Coletti, J
    MEDICAL PHYSICS, 2004, 31 (06) : 1863 - 1863