Simulation of Leksell Gamma Knife-4C System with Different Phantoms Using PHITS and Geant4

被引:0
|
作者
Hung, B. T. [1 ]
Duong, T. T. [2 ]
Ha, B. N. [2 ]
机构
[1] Vietnam Atom Energy Inst, 59 Ly Thuong Kiet, Hanoi, Vietnam
[2] Univ Sci & Technol, 1 Dai Co Viet, Hanoi, Vietnam
关键词
Leksell gamma knife; Reference computational phantoms; PHITS; Geant4; MODEL;
D O I
10.55981/aij.2023.1266
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
This study used PHITS and Geant4 code packages to simulate a Leksell Gamma Knife system in order to determine radiation dose distribution in two types of phantoms. The results observed in the water phantom with configurations of single source and 201 sources are in good accord with the prior research, including both simulation and experiment. Several characteristics of Leksell Gamma Knife 4C, such as dose profiles, output factor, FWHM, and penumbra size, are calculated based on Monte Carlo simulations, which show the best consistency with other results. The output factors for collimators of 14 mm, 8 mm, and 4 mm are 0.984, 0.949, and 0.872, respectively. The simulation results with an adult mesh-type reference phantom reveal considerable similarities with the established radiosurgery plans. It indicates that the absorbed dose in brain tumors was highest when utilizing the 18 mm collimator and subsequently reduced with collimator size to 0.65, 0.25, and 0.5 with the 14 mm, 8 mm, and 4 mm collimators, respectively. The absorbed dose has a very low value for other essential organs and decreases with distance from the brain tumor. These findings may explain why the dose to organs decreases linearly as target distance, volume, and collimator size increase.(c) 2023 Atom Indonesia. All rights reserved
引用
收藏
页码:13 / 20
页数:8
相关论文
共 50 条
  • [1] A modular Geant4 model of Leksell Gamma Knife Perfexion™
    Pipek, J.
    Novotny, J.
    Novotny, J., Jr.
    Kozubikova, P.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (24): : 7609 - 7623
  • [2] Geant4-based Monte Carlo simulation of the Leksell Gamma Knife®
    Romano, F.
    Sabini, M. G.
    Cuttone, G.
    Russo, G.
    Mongelli, V.
    Foroni, R.
    [J]. 2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 2581 - +
  • [3] Simulation of ALTEA calibration data with PHITS, FLUKA and GEANT4
    La Tessa, C.
    Di Fino, L.
    Larosa, M.
    Lee, K.
    Mancusi, D.
    Matthiae, D.
    Narici, L.
    Zaconte, V.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2009, 267 (21-22): : 3549 - 3557
  • [4] Development of an IAEA phase-space dataset for the Leksell Gamma Knife® Perfexion™ using multi-threaded Geant4 simulations
    Kim, Tae Hoon
    Schaarschmidt, Thomas
    Yang, Hye Jeong
    Kim, Yong Kyun
    Chun, Kook Jin
    Choi, Yona
    Chung, Hyun-Tai
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 64 : 222 - 229
  • [5] Independent dose validation system for Gamma Knife radiosurgery, using a DICOM-RT interface and Geant4
    Choi, Hyun Joon
    Chung, Hyun-Tai
    Sohn, Jason W.
    Min, Chul Hee
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 51 : 117 - 124
  • [6] Analysis of Radiation Dose Distribution Inhomogenity Effects in Gamma Knife Radiosurgery using Geant4
    Dagli, Ozlem
    Tanir, Ayse Gunes
    Kurt, Gokhan
    [J]. JOURNAL OF POLYTECHNIC-POLITEKNIK DERGISI, 2022, 25 (01): : 59 - 64
  • [7] GEANT4-based Monte Carlo Simulation of Beam Quality Correction Factors for the Leksell Gamma Knife® Perfexion™
    Thomas Schaarschmidt
    Tae Hoon Kim
    Yong Kyun Kim
    Hye Jeong Yang
    Hyun-Tai Chung
    [J]. Journal of the Korean Physical Society, 2018, 73 : 1814 - 1820
  • [8] GEANT4-based Monte Carlo Simulation of Beam Quality Correction Factors for the Leksell Gamma Knife® Perfexion
    Schaarschmidt, Thomas
    Kim, Tae Hoon
    Kim, Yong Kyun
    Yang, Hye Jeong
    Chung, Hyun-Tai
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2018, 73 (12) : 1814 - 1820
  • [9] Dosimetric comparison of the Leksell Gamma Knife Perfexion and 4C
    Novotny, Josef, Jr.
    Bhatnagar, Jagdish P.
    Niranjan, Ajay
    Quader, Mubina A.
    Huq, M. Saiful
    Bednarz, Greg
    Flickinger, John C.
    Kondziolka, Douglas
    Lunsford, L. Dade
    [J]. JOURNAL OF NEUROSURGERY, 2008, 109 : 8 - 14
  • [10] Simulation of LHCb RICH detectors using GEANT4
    Easo, S
    Belyaev, I
    Corti, G
    Jones, C
    Papanestis, J
    Pokorski, W
    Ranjard, F
    Robbe, P
    [J]. 2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2182 - 2185