Influence of rotor impeller structure on performance improvement of suspended axial flow blood pumps

被引:0
|
作者
Wang, Liang [1 ,2 ]
Yun, Zhong [1 ,3 ]
Tang, Xiaoyan [1 ]
Xiang, Chuang [2 ]
机构
[1] Cent South Univ, Sch Mech & Elect Engn, Changsha, Peoples R China
[2] Hunan Univ Arts & Sci, Coll Mech Engn, Changde, Peoples R China
[3] Cent South Univ, Sch Mech & Elect Engn, 932 South Lushan Rd, Changsha 410083, Hunan, Peoples R China
来源
关键词
Axial flow blood pump; impeller hub taper; number of blades; hemolysis; performance improvement; SHEAR-STRESS; HEMOLYSIS; DAMAGE; PREDICTION;
D O I
10.1177/03913988231225128
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: The hydrodynamic suspension structure design of the axial blood pump impeller can avoid the problems associated with using mechanical bearings. However, the particular impeller structure will impact the hydraulic performance and hemolysis of the blood pump.Method: This article combines computational fluid dynamics (CFD) with the Lagrange particle tracking method, aiming to improve the blood pump's hydraulic and hemolysis performance. It analyzes the flow characteristics and hemolysis performance inside the pump. It optimizes the taper of the impeller hub, the number of blades, and the inclination angle of the circumferential groove at the top of the blade.Results: Under certain rotational speed conditions, an increase in the taper of the impeller hub or the number of blades can increase the pumping pressure of a blood pump, but an increase in the number of blades will reduce the flow rate. The design of circumferential grooves at the top of the blade can increase the pumping pressure to a certain extent, with little impact on the hemolysis performance. The impeller structure is optimized based on the estimated hemolysis of each impeller model blood pump. It could be seen that when the pump blood pressure and flow rate were reached, the optimized impeller speed was reduced by 11.4%, and the estimated hemolysis value was reduced by 10.5%.Conclusion: In this paper, the rotor impeller structure of the blood pump was optimized to improve the hydraulic and hemolytic performance effectively, which can provide a reference for the related research of the axial flow blood pump using hydraulic suspension.
引用
收藏
页码:162 / 172
页数:11
相关论文
共 50 条
  • [41] Experimental study on the influence of impeller-tongue gap on the performance and flow-induced noise characteristics of centrifugal pumps
    Si Q.-R.
    Yuan S.-Q.
    Yuan J.-P.
    Yuan, Shou-Qi (shouqiy@ujs.edu.cn), 2016, Chinese Vibration Engineering Society (35): : 164 - 168and191
  • [43] Inlet Recirculation Influence to the Flow Structure of Centrifugal Impeller
    Yang Ce
    Chen Shan
    Li Du
    Yang Changmao
    Wang Yidi
    CHINESE JOURNAL OF MECHANICAL ENGINEERING, 2010, 23 (05) : 647 - 654
  • [44] Influence of impeller type on the flow structure in a stirred reactor
    Revstedt, J
    Fuchs, L
    Kovács, T
    Trägårdh, C
    AICHE JOURNAL, 2000, 46 (12) : 2373 - 2382
  • [45] Optimization of the operating point of an axial impeller without central shaft in blood flow
    Munoz-Perez, Johanna
    TECNOLOGIA EN MARCHA, 2022, 35 (03): : 48 - 59
  • [46] Investigating the Influence of Impeller Axial Thrust Balance Holes on the Flow and Overall Performance of a Cryogenic Liquid Turbine Expander
    Huo, Changjiang
    Sun, Jinju
    Song, Peng
    Sun, Shan
    JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2021, 143 (10):
  • [47] Investigation of rotor-stator interaction influence on flow fields in radial flow pumps
    Sedlar, M
    Mensik, P
    THIRD EUROPEAN CONFERENCE ON TURBOMACHINERY - VOLS A AND B: FLUID DYNAMICS AND THERMODYNAMICS, 1999, 1999 (1A-1B): : 1017 - 1025
  • [48] A design improvement strategy for axial blood pumps using computational fluid dynamics
    Burgreen, GW
    Antaki, JF
    Griffith, BP
    ASAIO JOURNAL, 1996, 42 (05) : M354 - M360
  • [49] The Evolution of Durable, Implantable Axial-Flow Rotary Blood Pumps
    Smith, P. Alex
    Wang, Yaxin
    Frazier, O. H.
    TEXAS HEART INSTITUTE JOURNAL, 2023, 50 (02)
  • [50] The Evolution of Durable, Implantable Axial-Flow Rotary Blood Pumps
    Smith, P. Alex
    Wang, Yaxin
    Frazier, O. H.
    ZEITGESCHICHTE, 2023, 50 (01)