A design improvement strategy for axial blood pumps using computational fluid dynamics

被引:22
|
作者
Burgreen, GW
Antaki, JF
Griffith, BP
机构
[1] Artificial Heart and Lung Program, Department of Surgery, University of Pittsburgh, Pittsburgh, PA
[2] University of Pittsburgh, Artificial Heart and Lung Program, Pittsburgh, PA 15219
关键词
D O I
10.1097/00002480-199609000-00010
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
During the initial stages of concept development of non traditional axial flow pumps, numeric simulation offers an attractive advantage. Computational fluid dynamics (CFD) provides the rationale to evolve the design numerically such that undesirable flow features may be significantly mitigated before a physical prototype is fabricated. The initial design of a novel axial flow blood pump is shown through CFD analysis to exhibit large regions of reverse flow. Such fluid dynamic behavior not only decreases the pump's hydrodynamic efficiency, but, more significantly, increases its overall potential for blood trauma and thrombogenesis. The design improvement strategy consists of creating a geometric model of the blood wetted surfaces and changing the associated geometric parameters such that more desirable fluid dynamic behavior is systematically attained with each incremental modification. The fluid flow through each new pump design is analyzed by numerically solving the incompressible Navier-Stokes equations in rotating coordinates. Marked improvements in the major fluid dynamic aspects of the axial flow pump were observed over an evolutionary sequence of four generations of pump design.
引用
收藏
页码:M354 / M360
页数:7
相关论文
共 50 条
  • [1] Design optimization of an axial blood pump with computational fluid dynamics
    Zhang, Yan
    Zhan, Zhao
    Gui, Xing-Min
    Sun, Han-Song
    Zhang, Hao
    Zheng, Zhe
    Zhou, Jian-Ye
    Zhu, Xiao-Dong
    Li, Guo-Rong
    Hu, Sheng-Shou
    Jin, Dong-Hai
    [J]. ASAIO JOURNAL, 2008, 54 (02) : 150 - 155
  • [2] Computational fluid dynamics (CFD) analysis to optimize the design of rotary blood pumps
    Nishida, Masahiro
    [J]. BIORHEOLOGY, 2021, 58 (3-4) : 94 - 95
  • [3] Computational fluid dynamics modeling and hemolysis analysis of axial blood pumps with various impeller structures
    XIA Dongdong
    Department of Engineering Mechanics
    [J]. Progress in Natural Science:Materials International, 2006, (09) : 993 - 997
  • [4] Computational fluid dynamics modeling and hemolysis analysis of axial blood pumps with various impeller structures
    Xia Dongdong
    Zhao Chunzhang
    Zhang Xiwen
    Bai Jing
    [J]. PROGRESS IN NATURAL SCIENCE-MATERIALS INTERNATIONAL, 2006, 16 (09) : 993 - 997
  • [5] Application of computational fluid dynamics techniques to blood pumps
    Sukumar, R
    Athavale, MM
    Makhijani, VB
    Przekwas, AJ
    [J]. ARTIFICIAL ORGANS, 1996, 20 (06) : 529 - 533
  • [6] A review of computational fluid dynamics analysis of blood pumps
    Behbahani, M.
    Behr, M.
    Hormes, M.
    Steinseifer, U.
    Arora, D.
    Coronado, O.
    Pasquali, M.
    [J]. EUROPEAN JOURNAL OF APPLIED MATHEMATICS, 2009, 20 : 363 - 397
  • [7] A new design and computational fluid dynamics study of an implantable axial blood pump
    Mojtaba Koochaki
    Hanieh Niroomand-Oscuii
    [J]. Australasian Physical & Engineering Sciences in Medicine, 2013, 36 : 417 - 422
  • [8] A new design and computational fluid dynamics study of an implantable axial blood pump
    Koochaki, Mojtaba
    Niroomand-Oscuii, Hanieh
    [J]. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2013, 36 (04) : 417 - 422
  • [9] Computational fluid dynamics as a development tool for rotary blood pumps
    Burgreen, GW
    Antaki, JF
    Wu, ZJ
    Holmes, AJ
    [J]. ARTIFICIAL ORGANS, 2001, 25 (05) : 336 - 340
  • [10] Crucial Aspects for Using Computational Fluid Dynamics as a Predictive Evaluation Tool for Blood Pumps
    Gross-Hardt, Sascha H.
    Sonntag, Simon J.
    Boehning, Fiete
    Steinseifer, Ulrich
    Schmitz-Rode, Thomas
    Kaufmann, Tim A. S.
    [J]. ASAIO JOURNAL, 2019, 65 (08) : 864 - 873