Effect of decreased contrast injection flow rate on aortic enhancement in 80-KV peak CT with contrast dose reduction

被引:0
|
作者
Morisaka, Hiroyuki [1 ,2 ]
Matsuura, Koichiro [2 ]
Yamaguchi, Haruomi [3 ]
Ichikawa, Tomoaki [4 ]
Onishi, Hiroshi [1 ]
机构
[1] Univ Yamanashi, Dept Radiol, Chuo, Yamanashi 4093898, Japan
[2] Saitama Med Univ, Diagnost Radiol, Int Med Ctr, Hidaka, Saitama, Japan
[3] Univ Tokyo, Grad Sch Med, Dept Radiol, Bunkyo Ku, Tokyo, Japan
[4] Gunma Univ, Dept Diagnost Radiol & Nucl Med, Grad Sch Med, Maebashi, Gunma, Japan
关键词
Aortic enhancement; computed tomography; flow rate; iodine contrast agent; LOW-TUBE-VOLTAGE; COMPUTED-TOMOGRAPHY; ANGIOGRAPHY; IODINE; PROTOCOLS; ARTERIAL; VOLUME;
D O I
10.1177/02841851211067144
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Effect of decreased injection flow rate of contrast agent at the same iodine dose and delivery rate on aortic enhancement has not been clearly elucidated. Purpose To evaluate the effect of decreased injection flow rate of contrast agent on aortic peak enhancement in a dynamic flow phantom and on aortic enhancement in clinical dynamic 80-kVp computed tomography (CT) with contrast dose reduction. Material and Methods In the dynamic flow phantom experiment, the effect of a decreased injection flow rate at the same total iodine dose and delivery rate on simulated aortic peak enhancement was evaluated. In the clinical retrospective study, we searched 312 patients with renal dysfunction who underwent an 80-kVp abdominal dynamic CT with 40% reduction of contrast agent from a standard 120-kVp protocol and measured the aortic enhancement at the level of the hepatic hilum. Independent predictors for aortic enhancement were determined by multiple linear regression analysis, and after adjustment of significant predictors, independent variables for acquiring optimal aortic enhancement, >= 300 HU, were determined by multiple logistic regression analysis. Results In the phantom experiment, decreased flow rate showed a significant but small descent effect (6%-9%) on simulated aortic peak enhancement. In the multiple linear regression analysis, only age was an independent predictor of aortic enhancement; there was no independent predictor for optimal age-adjusted aortic enhancement of >= 300 HU. Conclusions Decreased injection flow rate had a small influence on aortic enhancement in vitro but had no significant effect on the aortic enhancement in clinical dynamic 80-kVp CT.
引用
收藏
页码:353 / 359
页数:7
相关论文
共 50 条
  • [41] Contrast material injection protocol with the flow rate adjusted to the heart rate for dual source CT coronary angiography
    Xiaomei Zhu
    Wenping Chen
    Mei Li
    Yi Xu
    Hai Xu
    Yinsu Zhu
    Dehang Wang
    Lijun Tang
    The International Journal of Cardiovascular Imaging, 2012, 28 : 1557 - 1565
  • [42] Effect of Intravenous Injection Site on Contrast Enhancement of CT Thorax - Comparison Between Injection on Two Sides of Cubital
    Cui, Min-Yi
    Dong, Zhi
    Chan, Tao
    Luo, Yanji
    Huang, Kun
    Xu, Ling
    Li, Zi-Ping
    Li, Xiangmin
    CURRENT MEDICAL IMAGING REVIEWS, 2018, 14 (01) : 124 - 128
  • [43] Does a saline bolus after contrast injection increases liver, portal and aortic enhancement in CT? A prospective evaluation
    Chalaron, M
    Denys, AL
    Chevallier, P
    Prior, J
    Qanadli, SD
    Schnyder, P
    RADIOLOGY, 2002, 225 : 224 - 224
  • [44] HEPATIC CT CONTRAST ENHANCEMENT - EFFECT OF DOSE, DURATION OF INFUSION, AND TIME ELAPSED FOLLOWING INFUSION
    DEAN, PB
    VIOLANTE, MR
    MAHONEY, JA
    INVESTIGATIVE RADIOLOGY, 1980, 15 (02) : 158 - 161
  • [45] HEPATIC CT CONTRAST ENHANCEMENT - EFFECT OF DOSE, LENGTH OF INFUSION, AND TIME ELAPSED FOLLOWING INFUSION
    DEAN, PB
    VIOLANTE, MR
    INVESTIGATIVE RADIOLOGY, 1979, 14 (05) : 356 - 356
  • [46] The Frequency of Insufficient Contrast Enhancement of the Pulmonary Artery in Routine Contrast-enhanced Chest CT and Its Improvement With an Increased Injection Rate A Prospective Study
    Ozawa, Yoshiyuki
    Hara, Masaki
    Shibamoto, Yuta
    JOURNAL OF THORACIC IMAGING, 2011, 26 (01) : 42 - 47
  • [47] Dual-layer spectral detector CT for contrast agent concentration, dose and injection rate reduction: Utility in imaging of the superior mesenteric artery
    Lai, Lu-Yao
    Tan, Pan
    Jiang, Ying
    Wang, Fang
    Dong, Jing
    Huang, Meng-Ping
    Shu, Jian
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 150
  • [48] HEPATIC CT ENHANCEMENT .2. ALTERATIONS IN CONTRAST MATERIAL VOLUME AND RATE OF INJECTION WITHIN THE SAME PATIENTS
    CHAMBERS, TP
    BARON, RL
    LUSH, RM
    RADIOLOGY, 1994, 193 (02) : 518 - 522
  • [49] Optimization of contrast medium protocol in CT coronary arteriography: constant injection dose rate adapted to body weight
    Cao, Lizhen
    Du, Xiangying
    Li, Pengyu
    Sun, Zheng
    Zhang, Qiuhang
    Li, Kuncheng
    ACTA RADIOLOGICA, 2011, 52 (06) : 608 - 612
  • [50] EFFECT OF CONTRAST MEDIUM INJECTION IN AORTIC BULB ON MYOCARDIAL BLOOD FLOW . CORONAROGGRAPHY AND TERMINAL MYOCARDIAL CHANNELS
    FELIX, R
    HAHN, N
    MEUSER, HJ
    DUX, A
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1969, 111 (04): : 511 - &