Effect of decreased contrast injection flow rate on aortic enhancement in 80-KV peak CT with contrast dose reduction

被引:0
|
作者
Morisaka, Hiroyuki [1 ,2 ]
Matsuura, Koichiro [2 ]
Yamaguchi, Haruomi [3 ]
Ichikawa, Tomoaki [4 ]
Onishi, Hiroshi [1 ]
机构
[1] Univ Yamanashi, Dept Radiol, Chuo, Yamanashi 4093898, Japan
[2] Saitama Med Univ, Diagnost Radiol, Int Med Ctr, Hidaka, Saitama, Japan
[3] Univ Tokyo, Grad Sch Med, Dept Radiol, Bunkyo Ku, Tokyo, Japan
[4] Gunma Univ, Dept Diagnost Radiol & Nucl Med, Grad Sch Med, Maebashi, Gunma, Japan
关键词
Aortic enhancement; computed tomography; flow rate; iodine contrast agent; LOW-TUBE-VOLTAGE; COMPUTED-TOMOGRAPHY; ANGIOGRAPHY; IODINE; PROTOCOLS; ARTERIAL; VOLUME;
D O I
10.1177/02841851211067144
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Effect of decreased injection flow rate of contrast agent at the same iodine dose and delivery rate on aortic enhancement has not been clearly elucidated. Purpose To evaluate the effect of decreased injection flow rate of contrast agent on aortic peak enhancement in a dynamic flow phantom and on aortic enhancement in clinical dynamic 80-kVp computed tomography (CT) with contrast dose reduction. Material and Methods In the dynamic flow phantom experiment, the effect of a decreased injection flow rate at the same total iodine dose and delivery rate on simulated aortic peak enhancement was evaluated. In the clinical retrospective study, we searched 312 patients with renal dysfunction who underwent an 80-kVp abdominal dynamic CT with 40% reduction of contrast agent from a standard 120-kVp protocol and measured the aortic enhancement at the level of the hepatic hilum. Independent predictors for aortic enhancement were determined by multiple linear regression analysis, and after adjustment of significant predictors, independent variables for acquiring optimal aortic enhancement, >= 300 HU, were determined by multiple logistic regression analysis. Results In the phantom experiment, decreased flow rate showed a significant but small descent effect (6%-9%) on simulated aortic peak enhancement. In the multiple linear regression analysis, only age was an independent predictor of aortic enhancement; there was no independent predictor for optimal age-adjusted aortic enhancement of >= 300 HU. Conclusions Decreased injection flow rate had a small influence on aortic enhancement in vitro but had no significant effect on the aortic enhancement in clinical dynamic 80-kVp CT.
引用
收藏
页码:353 / 359
页数:7
相关论文
共 50 条
  • [31] Optimal dose and injection duration (injection rate) of contrast material for depiction of hypervascular hepatocellular carcinomas by multidetector CT
    Yanaga Y.
    Awai K.
    Nakayama Y.
    Nakaura T.
    Tamura Y.
    Funama Y.
    Aoyama M.
    Asada N.
    Yamashita Y.
    Radiation Medicine, 2007, 25 (6): : 278 - 288
  • [32] Computed Tomographic Angiography of the Abdomen and Pelvis in Azotemic Patients Utilizing 80-kV(p) Technique and Reduced Dose Iodinated Contrast: Comparison With Routine 120-kV(p) Technique
    Knipp, David
    Lane, Barton F.
    Mitchell, Jason W.
    Daly, Barry D.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2017, 41 (01) : 141 - 147
  • [33] Novel connecting tube for saline chaser in contrast-enhanced CT: the effect of spiral flow of saline on contrast enhancement
    Kidoh, Masafumi
    Nakaura, Takeshi
    Awai, Kazuo
    Yuba, Koji
    Kobayashi, Takayuki
    Park, Young-Kwang
    Yagi, Takanobu
    Harada, Kazunori
    Yamashita, Yasuyuki
    EUROPEAN RADIOLOGY, 2013, 23 (11) : 3213 - 3218
  • [34] Novel connecting tube for saline chaser in contrast-enhanced CT: the effect of spiral flow of saline on contrast enhancement
    Masafumi Kidoh
    Takeshi Nakaura
    Kazuo Awai
    Koji Yuba
    Takayuki Kobayashi
    Young-Kwang Park
    Takanobu Yagi
    Kazunori Harada
    Yasuyuki Yamashita
    European Radiology, 2013, 23 : 3213 - 3218
  • [35] Dose reduction in dynamic CT stress myocardial perfusion imaging: comparison of 80-kV/370-mAs and 100-kV/300-mAs protocols
    Makiko Fujita
    Kakuya Kitagawa
    Tatsuro Ito
    Yasuyuki Shiraishi
    Yusuke Kurobe
    Motonori Nagata
    Masaki Ishida
    Hajime Sakuma
    European Radiology, 2014, 24 : 748 - 755
  • [36] Dose reduction in dynamic CT stress myocardial perfusion imaging: comparison of 80-kV/370-mAs and 100-kV/300-mAs protocols
    Fujita, Makiko
    Kitagawa, Kakuya
    Ito, Tatsuro
    Shiraishi, Yasuyuki
    Kurobe, Yusuke
    Nagata, Motonori
    Ishida, Masaki
    Sakuma, Hajime
    EUROPEAN RADIOLOGY, 2014, 24 (03) : 748 - 755
  • [37] PCD-CT enables contrast media reduction in abdominal imaging compared to an individualized kV-adapted contrast media injection protocol on EID-CT
    Hoeijmakers, Eva J. I.
    Stammen, Lion
    Wildberger, Joachim E.
    Eijsvoogel, Nienke G.
    Hersbach, Johanna M.
    Pernot, Joey C. J. G.
    Flohr, Thomas G.
    Martens, Bibi
    Jeukens, Cecile R. L. P. N.
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 179
  • [38] HEPATIC ENHANCEMENT DURING HELICAL CT - A COMPARISON OF MODERATE RATE UNIPHASIC AND BIPHASIC CONTRAST INJECTION PROTOCOLS
    BIRNBAUM, BA
    JACOBS, JE
    YIN, DP
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (04) : 853 - 858
  • [39] 80-kV Pulmonary CT Angiography With 40 mL of Iodinated Contrast Material in Lean Patients: Comparison of Vascular Enhancement With Iodixanol (320 mg I/mL) and Iomeprol (400 mg I/mL)
    Faggioni, Lorenzo
    Neri, Emanuele
    Sbragia, Paola
    Pascale, Rachele
    D'Errico, Luigia
    Caramella, Davide
    Bartolozzi, Carlo
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (06) : 1220 - 1225
  • [40] Contrast material injection protocol with the flow rate adjusted to the heart rate for dual source CT coronary angiography
    Zhu, Xiaomei
    Chen, Wenping
    Li, Mei
    Xu, Yi
    Xu, Hai
    Zhu, Yinsu
    Wang, Dehang
    Tang, Lijun
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (06): : 1557 - 1565