The Frequency of Insufficient Contrast Enhancement of the Pulmonary Artery in Routine Contrast-enhanced Chest CT and Its Improvement With an Increased Injection Rate A Prospective Study

被引:19
|
作者
Ozawa, Yoshiyuki [1 ]
Hara, Masaki [1 ]
Shibamoto, Yuta [1 ]
机构
[1] Nagoya City Univ, Dept Radiol, Grad Sch Med Sci, Mizuho Ku, Nagoya, Aichi, Japan
关键词
contrast enhancement; pulmonary artery; contrast material; artifact; CT; ANGIOGRAPHY; FLOW;
D O I
10.1097/RTI.0b013e3181ced07a
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the frequency of insufficient contrast enhancement of the pulmonary artery (PA) during chest computed tomography (CT) and its improvement by an increased injection rate. Materials and Methods: Two hundred and eighty-eight (group A) and 278 (group B) consecutive patients underwent chest CT with the administration of 100 mL of a 300-mgI/mL nonionized contrast material through the antecubital vein using a power injector. The flow rate was 2 mL/s in group A and 3 mL/s in group B, and 50 mL saline was administered simultaneously using a dual injector. The scan delay was 30 s in both groups. The CT numbers in the pulmonary trunk, bilateral main PA, left atrium, and ascending and descending aortas were measured. Insufficient enhancement of the PA was defined as a CT number of the pulmonary trunk <= 180 HU. Results: Insufficient enhancement of the PA was observed in 21 of 288 patients (7.3%) in group A, whereas it was seen in only 9 of 278 patients (3.2%) in group B (P = 0.038). Conclusions: The use of a flow rate of 3 mL/s is associated with a significantly lower frequency of insufficient contrast enhancement of the PA, compared with the use of a lower flow rate of 2 mL/s with the same total volume of contrast.
引用
收藏
页码:42 / 47
页数:6
相关论文
共 50 条
  • [1] Routine contrast-enhanced CT is insufficient for TNM-staging of duodenal adenocarcinoma
    G. Litjens
    C. J. H. M. van Laarhoven
    M. Prokop
    E. J. M. van Geenen
    J. J. Hermans
    Abdominal Radiology, 2022, 47 : 3436 - 3445
  • [2] Routine contrast-enhanced CT is insufficient for TNM-staging of duodenal adenocarcinoma
    Litjens, G.
    van Laarhoven, C. J. H. M.
    Prokop, M.
    van Geenen, E. J. M.
    Hermans, J. J.
    ABDOMINAL RADIOLOGY, 2022, 47 (10) : 3436 - 3445
  • [3] CONTRAST-ENHANCED SPIRAL CT OF THE LIVER - EFFECT OF DIFFERENT AMOUNTS AND INJECTION RATES OF CONTRAST MATERIAL ON EARLY CONTRAST ENHANCEMENT
    SMALL, WC
    NELSON, RC
    BERNARDINO, ME
    BRUMMER, LT
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (01) : 87 - 92
  • [4] Prospective Evaluation of Artificial Intelligence Triage of Incidental Pulmonary Emboli on Contrast-Enhanced CT Examinations of the Chest or Abdomen
    Savage, Cody H.
    Abou Elkassem, Asser
    Hamki, Omar
    Sturdivant, Adam
    Benson, Don
    Grumley, Scott
    Tzabari, Jordan
    Junck, Kevin
    Li, Yufeng
    Li, Mei
    Tridandapani, Srini
    Smith, Andrew D.
    Rothenberg, Steven A.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2024, 223 (03)
  • [5] Multidetector multiphase contrast-enhanced liver CT: Prospective study comparing two contrast material injection rates on vascular and liver parenchyma enhancement in patients with varied cirrhotic status
    Alimenti, Alessandro
    Spahr, Laurent
    Loubeyre, Pierre
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2006, 30 (03) : 368 - 371
  • [6] A new method with variable injection parameters in contrast-enhanced CT: a phantom study for evaluating an aortic peak enhancement
    Terasawa K.
    Maruyama A.
    Tsukimata T.
    Radiological Physics and Technology, 2015, 8 (2) : 248 - 257
  • [7] Contrast-enhanced spiral CT of the liver: Effect of injection time on time to peak hepatic enhancement
    Department of Radiology, National Defense Medical College, 3-2, Namiki, Tokorozawa, Saitama 359, Japan
    J. COMPUT. ASSISTED TOMOGR., 4 (633-637):
  • [8] Contrast-enhanced spiral CT of the liver: Effect of injection time on time to peak hepatic enhancement
    Irie, T
    Kusano, S
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1996, 20 (04) : 633 - 637
  • [9] Injection rate of contrast medium affects diagnostic ability of dynamic contrast-enhanced magnetic resonance imaging for endometrial carcinoma: a prospective cohort study
    Xu, Donghui
    Jin, Aiping
    Ge, Yongqian
    Zhang, Yanmei
    GLAND SURGERY, 2021, 10 (08) : 2462 - 2470
  • [10] A prospective comparative study of contrast-enhanced CT, contrast-enhanced MRI and 18F-FDG PET/CT in the preoperative staging of colorectal cancer patients
    Guney, Isa Burak
    Teke, Zafer
    Kucuker, Kadir Alper
    Yalav, Orcun