Measurement method of tear meniscus height based on deep learning

被引:8
|
作者
Wan, Cheng [1 ]
Hua, Rongrong [1 ]
Guo, Ping [2 ,3 ]
Lin, Peijie [2 ,3 ]
Wang, Jiantao [2 ,3 ]
Yang, Weihua [2 ,3 ]
Hong, Xiangqian [2 ,3 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, Coll Elect Informat Engn, Nanjing, Peoples R China
[2] Jinan Univ, Shenzhen Eye Hosp, Shenzhen, Peoples R China
[3] Shenzhen Eye Inst, Shenzhen, Peoples R China
关键词
tear meniscus height; dry eye disease; automatic diagnosis; deep learning; image segmentation; DRY EYE DISEASE; HEALTHY-SUBJECTS; FILM STABILITY; REPEATABILITY; SUBCOMMITTEE; AGREEMENT;
D O I
10.3389/fmed.2023.1126754
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Tear meniscus height (TMH) is an important reference parameter in the diagnosis of dry eye disease. However, most traditional methods of measuring TMH are manual or semi-automatic, which causes the measurement of TMH to be prone to the influence of subjective factors, time consuming, and laborious. To solve these problems, a segmentation algorithm based on deep learning and image processing was proposed to realize the automatic measurement of TMH. To accurately segment the tear meniscus region, the segmentation algorithm designed in this study is based on the DeepLabv3 architecture and combines the partial structure of the ResNet50, GoogleNet, and FCN networks for further improvements. A total of 305 ocular surface images were used in this study, which were divided into training and testing sets. The training set was used to train the network model, and the testing set was used to evaluate the model performance. In the experiment, for tear meniscus segmentation, the average intersection over union was 0.896, the dice coefficient was 0.884, and the sensitivity was 0.877. For the central ring of corneal projection ring segmentation, the average intersection over union was 0.932, the dice coefficient was 0.926, and the sensitivity was 0.947. According to the evaluation index comparison, the segmentation model used in this study was superior to the existing model. Finally, the measurement outcome of TMH of the testing set using the proposed method was compared with manual measurement results. All measurement results were directly compared via linear regression; the regression line was y0.98x-0.02, and the overall correlation coefficient was r(2)0.94. Thus, the proposed method for measuring TMH in this paper is highly consistent with manual measurement and can realize the automatic measurement of TMH and assist clinicians in the diagnosis of dry eye disease.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Outcomes of 4-Snip Punctoplasty for Severe Punctal Stenosis: Measurement of Tear Meniscus Height by Optical Coherence Tomography
    Kim, Sung Eun
    Lee, Sung Jun
    Lee, Sang Yeul
    Yoon, Jin Sook
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2012, 153 (04) : 769 - 773
  • [42] Autofocus Method Based on Deep Learning in the Visual Measurement System
    Zheng, Bowen
    Liu, Shaojin
    Shen, Chengwu
    Li, Jianrong
    Han, Yan
    Sun, Haoyang
    LASER & OPTOELECTRONICS PROGRESS, 2024, 61 (24)
  • [43] The effect of sodium hyaluronate eyedrops on tear meniscus height determined by fluorescein photography
    Watanabe, T
    Kawashima, M
    Kawai, M
    Yamada, M
    Mashima, Y
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U429 - U429
  • [44] SCHIRMER TEST AFTER TOPICAL ANESTHESIA AND THE TEAR MENISCUS HEIGHT IN NORMAL EYES
    LAMBERTS, DW
    FOSTER, CS
    PERRY, HD
    ARCHIVES OF OPHTHALMOLOGY, 1979, 97 (06) : 1082 - 1085
  • [45] A deep learning knowledge distillation framework using knee MRI and arthroscopy data for meniscus tear detection
    Ying, Mengjie
    Wang, Yufan
    Yang, Kai
    Wang, Haoyuan
    Liu, Xudong
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2024, 11
  • [46] Automatic dynamic tear meniscus measurement in optical coherence tomography
    Bartuzel, Maciej M.
    Szczesna-Iskander, Dorota H.
    Iskander, D. Robert
    BIOMEDICAL OPTICS EXPRESS, 2014, 5 (08): : 2759 - 2768
  • [47] Meniscometry: A new method to measure tear meniscus curvature
    Bron, AJ
    Tiffany, JM
    Yokoi, N
    Banerjee, G
    Brown, NAP
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 744 - 744
  • [48] UTILIZATION OF LACRYDIAG INTERFEROMETRY TO OBTAIN OBJECTIVE ANALYSIS OF AQUEOUS LAYER AND MEASUREMENT OF TEAR MENISCUS HEIGHT PRE AND POST CATARACT SURGERY
    Diuguid, William David
    Carpenter, Christy Lee
    Carpenter, James Daniel
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)
  • [49] Deep learning-based automatic measurement system for patellar height: a multicenter retrospective study
    Liu, Zeyu
    Wu, Jiangjiang
    Gao, Xu
    Qin, Zhipeng
    Tian, Run
    Wang, Chunsheng
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2024, 19 (01):
  • [50] Development of Machine Learning-based Segmentation and Height Measurement Method for the Contact Wires
    Jeong D.
    Lee K.
    Park C.
    Kim D.
    Transactions of the Korean Institute of Electrical Engineers, 2024, 73 (02): : 382 - 388