Measurement method of tear meniscus height based on deep learning

被引:8
|
作者
Wan, Cheng [1 ]
Hua, Rongrong [1 ]
Guo, Ping [2 ,3 ]
Lin, Peijie [2 ,3 ]
Wang, Jiantao [2 ,3 ]
Yang, Weihua [2 ,3 ]
Hong, Xiangqian [2 ,3 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, Coll Elect Informat Engn, Nanjing, Peoples R China
[2] Jinan Univ, Shenzhen Eye Hosp, Shenzhen, Peoples R China
[3] Shenzhen Eye Inst, Shenzhen, Peoples R China
关键词
tear meniscus height; dry eye disease; automatic diagnosis; deep learning; image segmentation; DRY EYE DISEASE; HEALTHY-SUBJECTS; FILM STABILITY; REPEATABILITY; SUBCOMMITTEE; AGREEMENT;
D O I
10.3389/fmed.2023.1126754
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Tear meniscus height (TMH) is an important reference parameter in the diagnosis of dry eye disease. However, most traditional methods of measuring TMH are manual or semi-automatic, which causes the measurement of TMH to be prone to the influence of subjective factors, time consuming, and laborious. To solve these problems, a segmentation algorithm based on deep learning and image processing was proposed to realize the automatic measurement of TMH. To accurately segment the tear meniscus region, the segmentation algorithm designed in this study is based on the DeepLabv3 architecture and combines the partial structure of the ResNet50, GoogleNet, and FCN networks for further improvements. A total of 305 ocular surface images were used in this study, which were divided into training and testing sets. The training set was used to train the network model, and the testing set was used to evaluate the model performance. In the experiment, for tear meniscus segmentation, the average intersection over union was 0.896, the dice coefficient was 0.884, and the sensitivity was 0.877. For the central ring of corneal projection ring segmentation, the average intersection over union was 0.932, the dice coefficient was 0.926, and the sensitivity was 0.947. According to the evaluation index comparison, the segmentation model used in this study was superior to the existing model. Finally, the measurement outcome of TMH of the testing set using the proposed method was compared with manual measurement results. All measurement results were directly compared via linear regression; the regression line was y0.98x-0.02, and the overall correlation coefficient was r(2)0.94. Thus, the proposed method for measuring TMH in this paper is highly consistent with manual measurement and can realize the automatic measurement of TMH and assist clinicians in the diagnosis of dry eye disease.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Study of Tear Meniscus Height Measurement for Dry Eye Detection Using Smartphone Camera and Ring Light
    Okazaki, Kaito
    Hasegawa, Makoto
    INTERNATIONAL WORKSHOP ON ADVANCED IMAGING TECHNOLOGY, IWAIT 2023, 2023, 12592
  • [22] Tear meniscus measurement in the diagnosis of dry eye
    Mainstone, JC
    Bruce, AS
    Golding, TR
    CURRENT EYE RESEARCH, 1996, 15 (06) : 653 - 661
  • [23] Application of Visante Optical Coherence Tomography Tear Meniscus Height Measurement in the Diagnosis of Dry Eye Disease
    Ibrahim, Osama M. A.
    Dogru, Murat
    Takano, Yoji
    Satake, Yoshiyuki
    Wakamatsu, Tais Hitomi
    Fukagawa, Kazumi
    Tsubota, Kazuo
    Fujishima, Hiroshi
    OPHTHALMOLOGY, 2010, 117 (10) : 1923 - 1929
  • [24] Variability of the analysis of the tear meniscus height by optical coherence tomography
    Bitton, Etty
    Keech, Adam
    Simpson, Trefford
    Jones, Lyndon
    OPTOMETRY AND VISION SCIENCE, 2007, 84 (09) : 903 - 908
  • [25] Quantitative evaluation of tear meniscus height from fluorescein photographs
    Kawai, Masataka
    Yamada, Masakazu
    Kawashima, Motoko
    Inoue, Makoto
    Goto, Eiki
    Mashima, Yukihiko
    Tsubota, Kazuo
    CORNEA, 2007, 26 (04) : 403 - 406
  • [26] Evaluation of tear meniscus height using different clinical methods
    Niedernolte, Britta
    Trunk, Lisa
    Wolffsohn, James S.
    Pult, Heiko
    Bandlitz, Stefan
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2021, 104 (05) : 583 - 588
  • [27] Automated Measurement of Tear Meniscus Height with the Kowa DR-1α Tear Interferometer in Both Healthy Subjects and Dry Eye Patients
    Arita, Reiko
    Yabusaki, Katsumi
    Hirono, Taisuke
    Yamauchi, Takanori
    Ichihashi, Tadashi
    Fukuoka, Shima
    Morishige, Naoyuki
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (06) : 2092 - 2101
  • [28] Identification and diagnosis of meniscus tear by magnetic resonance imaging using a deep learning model
    Li, Jie
    Qian, Kun
    Liu, Jinyong
    Huang, Zhijun
    Zhang, Yuchen
    Zhao, Guoqian
    Wang, Huifen
    Li, Meng
    Liang, Xiaohan
    Zhou, Fang
    Yu, Xiuying
    Li, Lan
    Wang, Xingsong
    Yang, Xianfeng
    Jiang, Qing
    JOURNAL OF ORTHOPAEDIC TRANSLATION, 2022, 34 : 91 - 101
  • [29] Development of automatic measurement for patellar height based on deep learning and knee radiographs
    Ye, Qin
    Shen, Qiang
    Yang, Wei
    Huang, Shuai
    Jiang, Zhiqiang
    He, Linyang
    Gong, Xiangyang
    EUROPEAN RADIOLOGY, 2020, 30 (09) : 4974 - 4984
  • [30] Effect of non-invasive tear stability assessment on the upper and lower tear meniscus height
    Tian, Lei
    ACTA OPHTHALMOLOGICA, 2019, 97