Measurement method of tear meniscus height based on deep learning

被引:8
|
作者
Wan, Cheng [1 ]
Hua, Rongrong [1 ]
Guo, Ping [2 ,3 ]
Lin, Peijie [2 ,3 ]
Wang, Jiantao [2 ,3 ]
Yang, Weihua [2 ,3 ]
Hong, Xiangqian [2 ,3 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, Coll Elect Informat Engn, Nanjing, Peoples R China
[2] Jinan Univ, Shenzhen Eye Hosp, Shenzhen, Peoples R China
[3] Shenzhen Eye Inst, Shenzhen, Peoples R China
关键词
tear meniscus height; dry eye disease; automatic diagnosis; deep learning; image segmentation; DRY EYE DISEASE; HEALTHY-SUBJECTS; FILM STABILITY; REPEATABILITY; SUBCOMMITTEE; AGREEMENT;
D O I
10.3389/fmed.2023.1126754
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Tear meniscus height (TMH) is an important reference parameter in the diagnosis of dry eye disease. However, most traditional methods of measuring TMH are manual or semi-automatic, which causes the measurement of TMH to be prone to the influence of subjective factors, time consuming, and laborious. To solve these problems, a segmentation algorithm based on deep learning and image processing was proposed to realize the automatic measurement of TMH. To accurately segment the tear meniscus region, the segmentation algorithm designed in this study is based on the DeepLabv3 architecture and combines the partial structure of the ResNet50, GoogleNet, and FCN networks for further improvements. A total of 305 ocular surface images were used in this study, which were divided into training and testing sets. The training set was used to train the network model, and the testing set was used to evaluate the model performance. In the experiment, for tear meniscus segmentation, the average intersection over union was 0.896, the dice coefficient was 0.884, and the sensitivity was 0.877. For the central ring of corneal projection ring segmentation, the average intersection over union was 0.932, the dice coefficient was 0.926, and the sensitivity was 0.947. According to the evaluation index comparison, the segmentation model used in this study was superior to the existing model. Finally, the measurement outcome of TMH of the testing set using the proposed method was compared with manual measurement results. All measurement results were directly compared via linear regression; the regression line was y0.98x-0.02, and the overall correlation coefficient was r(2)0.94. Thus, the proposed method for measuring TMH in this paper is highly consistent with manual measurement and can realize the automatic measurement of TMH and assist clinicians in the diagnosis of dry eye disease.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Development of automatic measurement for patellar height based on deep learning and knee radiographs
    Qin Ye
    Qiang Shen
    Wei Yang
    Shuai Huang
    Zhiqiang Jiang
    Linyang He
    Xiangyang Gong
    European Radiology, 2020, 30 : 4974 - 4984
  • [32] Lower tear meniscus height measured by optical coherence tomography in children
    Martin-Garcia, Beatriz
    Palomo-Alvarez, Catalina
    Piedrahita-Alonso, Elena
    Gomez-de-Liano, Rosario
    Ferrer, Manuel Enrique Fuentes
    Arriola-Villalobos, Pedro
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2023, 43 (05) : 1059 - 1064
  • [33] Corneal infrared thermography and tear meniscus height in dry eye syndrome
    Merino, Maria L.
    Belmonte, Javier
    Rosas, Jose
    Acosta, M. Carmen
    Belmonte, Carlos
    Gallar, Juana
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [34] Tear Meniscus Height by Optical Coherence Tomography (OCT) and Ocular Itch
    Hom, Milton M.
    Nguyen, Andrew
    Bielory, Leonard
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2013, 131 (02) : AB113 - AB113
  • [35] A Fully Automatic Estimation of Tear Meniscus Height Using Artificial Intelligence
    Wang, Shaopan
    He, Xin
    He, Jiezhou
    Li, Shuang
    Chen, Yuguang
    Xu, Changsheng
    Lin, Xiang
    Kang, Jie
    Li, Wei
    Luo, Zhiming
    Liu, Zuguo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (13)
  • [36] Tear Meniscus Measurement by Spectral Optical Coherence Tomography
    Czajkowski, Grzegorz
    Kaluzny, Bartlomiej J.
    Laudencka, Adriana
    Malukiewicz, Grazyna
    Kaluzny, Jakub J.
    OPTOMETRY AND VISION SCIENCE, 2012, 89 (03) : 336 - 342
  • [37] Variability in the measurement of tear meniscus curvature using dacryomeniscometry
    Papas, EB
    Kasharvarsi, K
    Lum, E
    Ehrmann, K
    Ho, A
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S543 - S543
  • [38] Evaluation of tear meniscus height and lipid layer patterns in the tear film in domestic cats: An observational study
    Almutleb, Essam S.
    El-Hiti, Gamal A.
    Al-Okail, Fahad B.
    Altoaimi, Basal H.
    Almutairi, Meznah S.
    Baashen, Mashaaer A.
    Althomali, Mohammed
    Alanazi, Saud A.
    Masmali, Ali M.
    OPEN VETERINARY JOURNAL, 2024, 14 (03) : 846 - 851
  • [39] Prospective controlled study of vapor pressure tear osmolality and tear meniscus height in nasolacrimal duct obstruction
    Stahl, Ulrike
    Francis, Ian C.
    Stapleton, Fiona
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 141 (06) : 1051 - 1056