Measurement method of tear meniscus height based on deep learning

被引:8
|
作者
Wan, Cheng [1 ]
Hua, Rongrong [1 ]
Guo, Ping [2 ,3 ]
Lin, Peijie [2 ,3 ]
Wang, Jiantao [2 ,3 ]
Yang, Weihua [2 ,3 ]
Hong, Xiangqian [2 ,3 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, Coll Elect Informat Engn, Nanjing, Peoples R China
[2] Jinan Univ, Shenzhen Eye Hosp, Shenzhen, Peoples R China
[3] Shenzhen Eye Inst, Shenzhen, Peoples R China
关键词
tear meniscus height; dry eye disease; automatic diagnosis; deep learning; image segmentation; DRY EYE DISEASE; HEALTHY-SUBJECTS; FILM STABILITY; REPEATABILITY; SUBCOMMITTEE; AGREEMENT;
D O I
10.3389/fmed.2023.1126754
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Tear meniscus height (TMH) is an important reference parameter in the diagnosis of dry eye disease. However, most traditional methods of measuring TMH are manual or semi-automatic, which causes the measurement of TMH to be prone to the influence of subjective factors, time consuming, and laborious. To solve these problems, a segmentation algorithm based on deep learning and image processing was proposed to realize the automatic measurement of TMH. To accurately segment the tear meniscus region, the segmentation algorithm designed in this study is based on the DeepLabv3 architecture and combines the partial structure of the ResNet50, GoogleNet, and FCN networks for further improvements. A total of 305 ocular surface images were used in this study, which were divided into training and testing sets. The training set was used to train the network model, and the testing set was used to evaluate the model performance. In the experiment, for tear meniscus segmentation, the average intersection over union was 0.896, the dice coefficient was 0.884, and the sensitivity was 0.877. For the central ring of corneal projection ring segmentation, the average intersection over union was 0.932, the dice coefficient was 0.926, and the sensitivity was 0.947. According to the evaluation index comparison, the segmentation model used in this study was superior to the existing model. Finally, the measurement outcome of TMH of the testing set using the proposed method was compared with manual measurement results. All measurement results were directly compared via linear regression; the regression line was y0.98x-0.02, and the overall correlation coefficient was r(2)0.94. Thus, the proposed method for measuring TMH in this paper is highly consistent with manual measurement and can realize the automatic measurement of TMH and assist clinicians in the diagnosis of dry eye disease.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] A deep learning approach for the quantification of lower tear meniscus height
    Deng, Xianyu
    Tian, Lei
    Liu, Ziyu
    Zhou, Yongjin
    Jie, Ying
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2021, 68
  • [2] The agreement and repeatability of tear meniscus height measurement methods
    Johnson, ME
    Murphy, PJ
    OPTOMETRY AND VISION SCIENCE, 2005, 82 (12) : 1030 - 1037
  • [3] Automated Inferior Tear Meniscus Height Measurement in a Sequence of Video
    Azemin, Mohd Zulfaezal Che
    Ithnin, Mohd Hafidz
    Kamal, Khairidzan Mohd
    2012 IEEE EMBS CONFERENCE ON BIOMEDICAL ENGINEERING AND SCIENCES (IECBES), 2012,
  • [4] TMIS: a new image-based software application for the measurement of tear meniscus height
    Yang, Jiarui
    Zhu, Xingyu
    Liu, Yushi
    Jiang, Xiaodan
    Fu, Jiayu
    Ren, Xiaotong
    Li, Kaixiu
    Qiu, Weiqiang
    Li, Xuemin
    Yao, Jun
    ACTA OPHTHALMOLOGICA, 2019, 97 (07) : E973 - E980
  • [5] Deep Learning-Based Meniscus Tear Detection From Accelerated MRI
    Harman, Fatma
    Selver, Mustafa Alper
    Baris, Mustafa Mahmut
    Canturk, Ali
    Oksuz, Ilkay
    IEEE ACCESS, 2023, 11 : 144349 - 144363
  • [6] Interobserver variability of an open-source software for tear meniscus height measurement
    Pena-Verdeal, Hugo
    Garcia-Resua, Carlos
    Barreira, Noelia
    Giraldez, Maria J.
    Yebra-Pimentel, Eva
    CONTACT LENS & ANTERIOR EYE, 2016, 39 (04): : 249 - 256
  • [7] Determination of tear meniscus height using a novel method based upon optical coherence tomography
    Jones, LW
    Rahman, S
    Leech, R
    Simpson, T
    Fonn, D
    Vehige, JG
    Simmons, PA
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U429 - U429
  • [8] Clinical assessment of the lower tear meniscus height
    Garcia-Resua, Carlos
    Santodomingo-Rubido, Jacinto
    Lira, Madalena
    Jesus Giraldez, Maria
    Yebra-Pimentel Vilar, Eva
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2009, 29 (05) : 526 - 534
  • [9] Next-Generation Tear Meniscus Height Detecting and Measuring Smartphone-Based Deep Learning Algorithm Leads in Dry Eye Management
    Nejat, Farhad
    Eghtedari, Shima
    Alimoradi, Fatemeh
    OPHTHALMOLOGY SCIENCE, 2024, 4 (05):
  • [10] Determination of inferior tear meniscus height and inferior tear meniscus volume using optical coherence tomography
    Jones, LW
    Rahman, S
    Leech, R
    Simpson, T
    Fonn, D
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U132 - U132