Computational and experimental performance assessment of rectangular sectioned solar air heater duct provided with new curved ribs

被引:1
|
作者
Deshpande, Harshad [1 ,2 ,4 ]
Raibhole, Vaijanath [3 ]
机构
[1] Savitribai Phule Pune Univ SPPU, GH Raisoni Coll Engn & Management, Dept Mech Engn, Pune, Maharashtra, India
[2] Savitribai Phule Pune Univ SPPU, PESs Modern Coll Engn, Dept Mech Engn, Pune, Maharashtra, India
[3] Savitribai Phule Pune Univ SPPU, MES Coll Engn, Dept Mech Engn, Pune, Maharashtra, India
[4] Savitribai Phule Pune Univ SPPU, GH Raisoni Coll Engn & Management, Dept Mech Engn, Pune 412207, Maharashtra, India
关键词
computational; curved ribs; drying; geometrical factors; interrupted pattern; numerical simulations; performance analysis; truncation; FRICTION FACTOR CORRELATIONS; V-SHAPED RIBS; ABSORBER PLATE; FLUID-FLOW; THERMAL PERFORMANCE; TRANSFER AUGMENTATION; TRANSFER ENHANCEMENT; ROUGHNESS; CHANNEL; GAP;
D O I
10.1002/htj.23014
中图分类号
O414.1 [热力学];
学科分类号
摘要
There are many applications, such as fruits, paddy rice drying, and so on, where air heaters are comprehensively used. The provision of ribs in solar energy-based air heaters has been accredited to be a beneficial approach for escalating its thermal performance. This investigation reveals the performance evaluation of a rectangular sectioned solar air heater duct placed with the curved type of ribs organized in noncontinuous and truncation patterns. Influence of variation of pitch ratio (4.0-12.0), block-age ratio (0.06-0.1), the ratio of rib height to the radius of rib curvature (0.75-1), and the ratio of rib truncation gap to its height (0-0.75) at different values of Reynolds's numbers (Re) in the range 12,000-37,000 on the performance revealing factors explicitly heat transfer augmentation factor, the ratio of friction factor, as well as overall thermal performance enhancement (OTPE) have been discussed. The experimentation was performed on a similar rectangular air heater as that of numerical simulation with the same boundary conditions. It is figured out from numerical simulation that the provision of a central truncation gap in the arrangement of ribs helped in the development of vortices with minimal pressure loss due to friction. The greatest Nusselt number augmentation ratio between ribbed and plain plates that was attained is of the order of 2.01 for a pitch ratio of 9.0, blockage ratio of 0.08, the ratio of rib height to the radius of rib curvature 0.25 at the highest value of Re. The obtained friction factor ratio between the ribbed plate and the plain plate is of the order of 2.34 for p/y = 9.0 at maximum Re. The highest value of overall thermal performance enhancement (OTPE) is attained as 1.52 at the pitch ratio of 9, at the maximum value of Re. The central truncation gap of the rib pattern promoted the creation of vortices with a decreased pressure loss penalty. The uppermost value of the factor presenting overall thermal performance enhancement in this work is far superior to unity. This suggests that adding curved ribs to the air heater's duct is a helpful way to improve its overall performance. Empirical correlations have been established between the Nusselt number and geometrical parameters, likewise the friction factor and geometrical parameters using the regression study. The values of the Nusselt number, and friction factor that come from experimental work and developed empirical correlations fall between the highest deviation limits of +/- 9% and +/- 8%, respectively. This work is certainly helpful in the context of solar air heaters used for applications such as drying paddy rice.
引用
收藏
页码:1924 / 1948
页数:25
相关论文
共 50 条
  • [1] Influence of Rectangular Ribs on Exergetic Performance in a Triangular Duct Solar Air Heater
    Nidhul, Kottayat
    Kumar, Sachin
    Yadav, Ajay Kumar
    Anish, S.
    JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2020, 12 (05)
  • [2] CFD Based Numerical Performance Assessment of a Solar Air Heater Duct Roughened by Transverse- Trapezoidal Sectioned Ribs
    Al-Chlaihawi, Kadhim K. Idan
    Alyas, Bahjat Hassan
    Badr, Abdullah A.
    INTERNATIONAL JOURNAL OF HEAT AND TECHNOLOGY, 2023, 41 (05) : 1273 - 1281
  • [3] Experimental Assessment of Thermohydraulic Performance of a Rectangular Solar Air Heater Duct Using Twisted V-Shaped Staggered Ribs
    Kumar, Dheeraj
    Layek, Apurba
    JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2023, 15 (04)
  • [4] A critical review on artificial roughness provided in rectangular solar air heater duct
    Alam, Tabish
    Kim, Man-Hoe
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2017, 69 : 387 - 400
  • [5] Performance prediction of solar air heater having roughened duct provided with transverse and inclined ribs as artificial roughness
    Varun
    Patnaik, Amar
    Saini, R. P.
    Singal, S. K.
    Siddhartha
    RENEWABLE ENERGY, 2009, 34 (12) : 2914 - 2922
  • [6] CFD based analysis of heat transfer enhancement in solar air heater provided with transverse rectangular ribs
    Boulemtafes-Boukadoum, A.
    Benzaoui, A.
    TECHNOLOGIES AND MATERIALS FOR RENEWABLE ENERGY, ENVIRONMENT AND SUSTAINABILITY (TMREES14 - EUMISD), 2014, 50 : 761 - 772
  • [7] Experimental study on thermo-hydraulic performance of a solar air heater with rectangular perforated duct inserts
    Arunkumar, H. S.
    Kumar, Shiva
    Karanth, K. Vasudeva
    SOLAR ENERGY, 2021, 227 : 179 - 189
  • [8] Performance enhancement of a solar air heater using rectangular perforated duct inserts
    Arunkumar, H.S.
    Kumar, Shiva
    Vasudeva Karanth, K.
    Thermal Science and Engineering Progress, 2022, 34
  • [9] CFD based performance analysis of a solar air heater duct provided with artificial roughness
    Kumar, Sharad
    Saini, R. P.
    RENEWABLE ENERGY, 2009, 34 (05) : 1285 - 1291
  • [10] Performance analysis of solar air heater duct roughened with multigap V-down ribs combined with staggered ribs
    Deo, Narinderpal Singh
    Chander, Subhash
    Saini, J. S.
    RENEWABLE ENERGY, 2016, 91 : 484 - 500