Computational and experimental performance assessment of rectangular sectioned solar air heater duct provided with new curved ribs

被引:1
|
作者
Deshpande, Harshad [1 ,2 ,4 ]
Raibhole, Vaijanath [3 ]
机构
[1] Savitribai Phule Pune Univ SPPU, GH Raisoni Coll Engn & Management, Dept Mech Engn, Pune, Maharashtra, India
[2] Savitribai Phule Pune Univ SPPU, PESs Modern Coll Engn, Dept Mech Engn, Pune, Maharashtra, India
[3] Savitribai Phule Pune Univ SPPU, MES Coll Engn, Dept Mech Engn, Pune, Maharashtra, India
[4] Savitribai Phule Pune Univ SPPU, GH Raisoni Coll Engn & Management, Dept Mech Engn, Pune 412207, Maharashtra, India
关键词
computational; curved ribs; drying; geometrical factors; interrupted pattern; numerical simulations; performance analysis; truncation; FRICTION FACTOR CORRELATIONS; V-SHAPED RIBS; ABSORBER PLATE; FLUID-FLOW; THERMAL PERFORMANCE; TRANSFER AUGMENTATION; TRANSFER ENHANCEMENT; ROUGHNESS; CHANNEL; GAP;
D O I
10.1002/htj.23014
中图分类号
O414.1 [热力学];
学科分类号
摘要
There are many applications, such as fruits, paddy rice drying, and so on, where air heaters are comprehensively used. The provision of ribs in solar energy-based air heaters has been accredited to be a beneficial approach for escalating its thermal performance. This investigation reveals the performance evaluation of a rectangular sectioned solar air heater duct placed with the curved type of ribs organized in noncontinuous and truncation patterns. Influence of variation of pitch ratio (4.0-12.0), block-age ratio (0.06-0.1), the ratio of rib height to the radius of rib curvature (0.75-1), and the ratio of rib truncation gap to its height (0-0.75) at different values of Reynolds's numbers (Re) in the range 12,000-37,000 on the performance revealing factors explicitly heat transfer augmentation factor, the ratio of friction factor, as well as overall thermal performance enhancement (OTPE) have been discussed. The experimentation was performed on a similar rectangular air heater as that of numerical simulation with the same boundary conditions. It is figured out from numerical simulation that the provision of a central truncation gap in the arrangement of ribs helped in the development of vortices with minimal pressure loss due to friction. The greatest Nusselt number augmentation ratio between ribbed and plain plates that was attained is of the order of 2.01 for a pitch ratio of 9.0, blockage ratio of 0.08, the ratio of rib height to the radius of rib curvature 0.25 at the highest value of Re. The obtained friction factor ratio between the ribbed plate and the plain plate is of the order of 2.34 for p/y = 9.0 at maximum Re. The highest value of overall thermal performance enhancement (OTPE) is attained as 1.52 at the pitch ratio of 9, at the maximum value of Re. The central truncation gap of the rib pattern promoted the creation of vortices with a decreased pressure loss penalty. The uppermost value of the factor presenting overall thermal performance enhancement in this work is far superior to unity. This suggests that adding curved ribs to the air heater's duct is a helpful way to improve its overall performance. Empirical correlations have been established between the Nusselt number and geometrical parameters, likewise the friction factor and geometrical parameters using the regression study. The values of the Nusselt number, and friction factor that come from experimental work and developed empirical correlations fall between the highest deviation limits of +/- 9% and +/- 8%, respectively. This work is certainly helpful in the context of solar air heaters used for applications such as drying paddy rice.
引用
收藏
页码:1924 / 1948
页数:25
相关论文
共 50 条
  • [21] CFD based performance analysis of solar air heater provided with artificial roughness in the form of V - Shaped ribs
    Sharma, Mohit
    Bhargva, Mohit
    MATERIALS TODAY-PROCEEDINGS, 2022, 63 : 595 - 601
  • [22] Experimental and CFD analysis of solar air heater duct roughened with multiple broken transverse ribs: A comparative study
    Singh, Inderjeet
    Vardhan, Sachit
    Singh, Sukhmeet
    Singh, Amritpal
    SOLAR ENERGY, 2019, 188 : 519 - 532
  • [23] Experimental Performance Analysis of Solar Air Heater With Innovative Perforated Semi-Conical Ribs
    Shankar, Ravi
    Kumar, Rajeev
    Pandey, Arun Kumar
    Thakur, Deep Singh
    Journal of Solar Energy Engineering, 2025, 147 (03)
  • [24] Computational and experimental assessment of solar air heater roughened with six different baffles
    Sharma, Sachin
    Das, Randip Kumar
    Kulkarni, Kishor
    CASE STUDIES IN THERMAL ENGINEERING, 2021, 27
  • [25] Performance study of solar air heater duct with gap in V-rib with symmetrical gap and staggered ribs
    Sumer Singh Patel
    Atul Lanjewar
    Heat and Mass Transfer, 2019, 55 : 2517 - 2532
  • [26] Performance study of solar air heater duct with gap in V-rib with symmetrical gap and staggered ribs
    Patel, Sumer Singh
    Lanjewar, Atul
    HEAT AND MASS TRANSFER, 2019, 55 (09) : 2517 - 2532
  • [27] Thermal performance analysis of triangular solar air heater duct having broken V-shaped ribs
    Agrawal R.K.
    Prasad R.S.
    International Journal of Ambient Energy, 2024, 45 (01)
  • [28] Optimization of artificial roughness parameters in a solar air heater duct roughened with hybrid ribs
    Gill, Raminder Singh
    Hans, Vishavjeet Singh
    Singh, Rupinder Pal
    APPLIED THERMAL ENGINEERING, 2021, 191
  • [29] Heat transfer enhancement in solar air heater duct with conical protrusion roughness ribs
    Alam, Tabish
    Kim, Man-Hoe
    APPLIED THERMAL ENGINEERING, 2017, 126 : 458 - 469
  • [30] A parametric analysis of rectangular rib roughened triangular duct solar air heater using computational fluid dynamics
    Kumar, Rajneesh
    Kumar, Anoop
    Goel, Varun
    SOLAR ENERGY, 2017, 157 : 1095 - 1107