Computational and experimental performance assessment of rectangular sectioned solar air heater duct provided with new curved ribs

被引:1
|
作者
Deshpande, Harshad [1 ,2 ,4 ]
Raibhole, Vaijanath [3 ]
机构
[1] Savitribai Phule Pune Univ SPPU, GH Raisoni Coll Engn & Management, Dept Mech Engn, Pune, Maharashtra, India
[2] Savitribai Phule Pune Univ SPPU, PESs Modern Coll Engn, Dept Mech Engn, Pune, Maharashtra, India
[3] Savitribai Phule Pune Univ SPPU, MES Coll Engn, Dept Mech Engn, Pune, Maharashtra, India
[4] Savitribai Phule Pune Univ SPPU, GH Raisoni Coll Engn & Management, Dept Mech Engn, Pune 412207, Maharashtra, India
关键词
computational; curved ribs; drying; geometrical factors; interrupted pattern; numerical simulations; performance analysis; truncation; FRICTION FACTOR CORRELATIONS; V-SHAPED RIBS; ABSORBER PLATE; FLUID-FLOW; THERMAL PERFORMANCE; TRANSFER AUGMENTATION; TRANSFER ENHANCEMENT; ROUGHNESS; CHANNEL; GAP;
D O I
10.1002/htj.23014
中图分类号
O414.1 [热力学];
学科分类号
摘要
There are many applications, such as fruits, paddy rice drying, and so on, where air heaters are comprehensively used. The provision of ribs in solar energy-based air heaters has been accredited to be a beneficial approach for escalating its thermal performance. This investigation reveals the performance evaluation of a rectangular sectioned solar air heater duct placed with the curved type of ribs organized in noncontinuous and truncation patterns. Influence of variation of pitch ratio (4.0-12.0), block-age ratio (0.06-0.1), the ratio of rib height to the radius of rib curvature (0.75-1), and the ratio of rib truncation gap to its height (0-0.75) at different values of Reynolds's numbers (Re) in the range 12,000-37,000 on the performance revealing factors explicitly heat transfer augmentation factor, the ratio of friction factor, as well as overall thermal performance enhancement (OTPE) have been discussed. The experimentation was performed on a similar rectangular air heater as that of numerical simulation with the same boundary conditions. It is figured out from numerical simulation that the provision of a central truncation gap in the arrangement of ribs helped in the development of vortices with minimal pressure loss due to friction. The greatest Nusselt number augmentation ratio between ribbed and plain plates that was attained is of the order of 2.01 for a pitch ratio of 9.0, blockage ratio of 0.08, the ratio of rib height to the radius of rib curvature 0.25 at the highest value of Re. The obtained friction factor ratio between the ribbed plate and the plain plate is of the order of 2.34 for p/y = 9.0 at maximum Re. The highest value of overall thermal performance enhancement (OTPE) is attained as 1.52 at the pitch ratio of 9, at the maximum value of Re. The central truncation gap of the rib pattern promoted the creation of vortices with a decreased pressure loss penalty. The uppermost value of the factor presenting overall thermal performance enhancement in this work is far superior to unity. This suggests that adding curved ribs to the air heater's duct is a helpful way to improve its overall performance. Empirical correlations have been established between the Nusselt number and geometrical parameters, likewise the friction factor and geometrical parameters using the regression study. The values of the Nusselt number, and friction factor that come from experimental work and developed empirical correlations fall between the highest deviation limits of +/- 9% and +/- 8%, respectively. This work is certainly helpful in the context of solar air heaters used for applications such as drying paddy rice.
引用
收藏
页码:1924 / 1948
页数:25
相关论文
共 50 条
  • [41] Performance of solar air heater ducts with different types of ribs on the absorber plate
    Tanda, Giovanni
    ENERGY, 2011, 36 (11) : 6651 - 6660
  • [42] Revisiting the effect of ribs on performance of solar air heater using CFD approach
    Yadav, Anil Singh
    Agrawal, Abhay
    Sharma, Abhishek
    Gupta, Abhay
    MATERIALS TODAY-PROCEEDINGS, 2022, 63 : 240 - 252
  • [43] Evaluation of the performance of an improved solar air heater with "S" shaped ribs with gap
    Wang, Dengjia
    Liu, Jin
    Liu, Yanfeng
    Wang, Yingying
    Li, Bojia
    Liu, Jiaping
    SOLAR ENERGY, 2020, 195 : 89 - 101
  • [44] Performance Investigation of a Solar Air Heater Artificially Roughened With Joukowski Airfoil Ribs
    Roy, Bibhrat
    Reddy, Desireddy Shashidhar
    Khan, Mohd. Kaleem
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2024, 146 (01):
  • [45] Thermohydraulic performance of hybrid ribs pattern combining V and arc shape ribs in solar air heater
    Alam, Tabish
    Gupta, Deepak
    EXPERIMENTAL HEAT TRANSFER, 2024, 37 (07) : 1084 - 1099
  • [46] Thermo-Hydraulic Characteristics Evaluation of a Triangular Solar Air Heater Duct Having Transverse Ribs With Gaps: An Experimental Study
    Mahanand, Yadaba
    Senapati, Jnana Ranjan
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2024, 146 (04):
  • [47] Experimental Investigation of Thermohydraulic Performance of the Solar Air Heater Having Arc-Shaped Ribs With Multiple Gaps
    Jain, Sheetal Kumar
    Agrawal, Ghanshyam Das
    Misra, Rohit
    JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2020, 12 (01)
  • [48] THERMAL PERFORMANCE OF A NEW SOLAR AIR HEATER
    TIRIS, C
    OZBALTA, N
    TIRIS, M
    DINCER, I
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 1995, 22 (03) : 411 - 423
  • [49] Performance characteristics of a new curved double-pass counter flow solar air heater
    Kumar, Amit
    Singh, Ajeet Pratap
    Akshayveer
    Singh, O. P.
    ENERGY, 2022, 239
  • [50] Performance characteristics of a new curved double-pass counter flow solar air heater
    Kumar, Amit
    Singh, Ajeet Pratap
    Akshayveer
    Singh, O.P.
    Energy, 2022, 239