Performance prediction of solar air heater having roughened duct provided with transverse and inclined ribs as artificial roughness

被引:48
|
作者
Varun [1 ]
Patnaik, Amar [1 ]
Saini, R. P. [2 ]
Singal, S. K. [2 ]
Siddhartha [1 ]
机构
[1] NIT, Mech Engg Dept, Hamirpur 177005, India
[2] Indian Inst Technol, AHEC, Roorkee 247667, Uttar Pradesh, India
关键词
Roughness element; Effective efficiency; Thermal efficiency; Taguchi method; FRICTION;
D O I
10.1016/j.renene.2009.04.030
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
An experimental study has been carried out to investigate the effective efficiency of a solar air heater duct provided with transverse and inclined ribs as artificial roughness elements on the absorber plate. The range of parameters considered for the present investigation; Reynolds number (Re) 2000-14,000, relative roughness pitch (p/e) 3-8 and a fixed value of relative roughness height (e/D) of 0.030. The effective efficiency has been computed based on the experimentally determined values for the range of parameters considered. Further an attempt has also been made to optimize the thermal efficiency for the same system under similar conditions by Taguchi method. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2914 / 2922
页数:9
相关论文
共 50 条
  • [1] Optimization of artificial roughness parameters in a solar air heater duct roughened with hybrid ribs
    Gill, Raminder Singh
    Hans, Vishavjeet Singh
    Singh, Rupinder Pal
    APPLIED THERMAL ENGINEERING, 2021, 191
  • [2] Investigation of thermal performance of solar air heater having roughness elements as a combination of inclined and transverse ribs on the absorber plate
    Varun
    Saini, R. P.
    Singal, S. K.
    RENEWABLE ENERGY, 2008, 33 (06) : 1398 - 1405
  • [3] Numerical Investigation of Solar Air Heater Duct with Square Transverse and Inclined Ribs
    Lad, Gaurav
    Raghuvanshi, Nikhil
    Mehrotra, Pranshu
    Srivastava, Ankur
    ADVANCES IN FLUID AND THERMAL ENGINEERING, 2019, : 445 - 458
  • [4] CFD based performance analysis of a solar air heater duct provided with artificial roughness
    Kumar, Sharad
    Saini, R. P.
    RENEWABLE ENERGY, 2009, 34 (05) : 1285 - 1291
  • [5] CFD analysis of solar air heater duct having square wave profiled transverse ribs as roughness elements
    Singh, Inderjeet
    Singh, Sukhmeet
    SOLAR ENERGY, 2018, 162 : 442 - 453
  • [6] Experimental investigation on performance of a double pass artificial roughened solar air heater duct having roughness elements of the combination of discrete multi V shaped and staggered ribs
    Ravi, Ravi Kant
    Saini, R. P.
    ENERGY, 2016, 116 : 507 - 516
  • [7] A critical review on artificial roughness provided in rectangular solar air heater duct
    Alam, Tabish
    Kim, Man-Hoe
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2017, 69 : 387 - 400
  • [8] CFD Based Numerical Performance Assessment of a Solar Air Heater Duct Roughened by Transverse- Trapezoidal Sectioned Ribs
    Al-Chlaihawi, Kadhim K. Idan
    Alyas, Bahjat Hassan
    Badr, Abdullah A.
    INTERNATIONAL JOURNAL OF HEAT AND TECHNOLOGY, 2023, 41 (05) : 1273 - 1281
  • [9] CFD based performance analysis of solar air heater provided with artificial roughness in the form of V - Shaped ribs
    Sharma, Mohit
    Bhargva, Mohit
    MATERIALS TODAY-PROCEEDINGS, 2022, 63 : 595 - 601
  • [10] Experimental and CFD analysis of solar air heater duct roughened with multiple broken transverse ribs: A comparative study
    Singh, Inderjeet
    Vardhan, Sachit
    Singh, Sukhmeet
    Singh, Amritpal
    SOLAR ENERGY, 2019, 188 : 519 - 532