Numerical study on the thermal performance of water flow window fed with air-conditioning condensate

被引:6
|
作者
Chan, Lok Shun [1 ]
机构
[1] City Univ Hong Kong, Div Bldg Sci & Technol, Kowloon, Tat Chee Ave, Hong Kong, Peoples R China
关键词
Water flow window; Condensate recovery; Building energy simulation; ENERGY; CONSERVATION; SYSTEMS; UNIT; HOT;
D O I
10.1016/j.energy.2022.125633
中图分类号
O414.1 [热力学];
学科分类号
摘要
A water flow window (WFW) fed with potable water is deemed as an effective system for absorbing incoming heat energy through the glazing area of a window. In this study, condensate formed in an air-conditioning (A/C) system is applied in a WFW for reducing heat gain and electricity consumption of a building. There is no need to consume any potable water. Through building energy simulations and numerical computation, this study unveils that a fully air-conditioned office building operating under a subtropical climate can produce condensate of sufficient flow rate to absorb heat energy from the glazing panes of an A/C condensate fed WFW system. The surface temperature of an outer glazing pane in an A/C condensate fed WFW system can be dropped by 16.3 degrees C when compared to a Low-e glass window. Moreover, an A/C condensate fed WFW can offer better thermal performance than a conventional WFW. When comparing to a Low-e glass case, an A/C condensate fed WFW facing four different orientations (N, E, S & W) can give reduction percentages of transmitted heat gain ranging from 57.2% to 63.5%. This A/C condensate fed WFW system shows a promising performance and has good potential for real application in commercial buildings.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Study on thermal performance of air-Type radiation air-conditioning system
    Kohata Y.
    Matsuda C.
    Mino Y.
    Udagawa Y.
    Hayama H.
    1600, Architectural Institute of Japan (82): : 883 - 891
  • [2] Performance Enhancement of Window-Type Air-Conditioning Units
    Al-Sayyab, Ali K. Shaker
    INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2018, 26 (02)
  • [3] Simulation study on estimation method for flow rate in air-conditioning system with water thermal energy storage
    Takeshima, Ken-ichiro
    Sagara, Kazunobu
    Yamanaka, Toshio
    Kotani, Hisashi
    BUILDING SIMULATION 2007, VOLS 1-3, PROCEEDINGS, 2007, : 1334 - 1340
  • [4] Numerical study of the air flow through an air-conditioning unit on high-speed trains
    Li, Xueliang
    Wu, Fan
    Tao, Yu
    Yang, Mingzhi
    Newman, Robert
    Vainchtein, Dmitri
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2019, 187 : 26 - 35
  • [5] Quantitative and qualitative characteristics of condensate water of home air-conditioning system in Iran
    Alipour, Vali
    Mahvi, Amir Hossein
    Rezaei, Leila
    DESALINATION AND WATER TREATMENT, 2015, 53 (07) : 1834 - 1839
  • [6] Air-conditioning for a window-less building
    Roedler, F
    ZEITSCHRIFT DES VEREINES DEUTSCHER INGENIEURE, 1937, 81 : 1281 - 1281
  • [7] Numerical optimization on thermal performance characteristics of interior walls based on air-conditioning intermittent running
    Meng, Xi
    Hu, Wentao
    Cao, Ying
    Huang, Yisheng
    Du, Junfei
    Gan, Yanna
    CASE STUDIES IN THERMAL ENGINEERING, 2018, 12 : 608 - 619
  • [8] A numerical and experimental study of turbulent flow through the evaporator coil in an air-conditioning unit
    Xu, ZG
    Gotham, DHT
    Collins, MW
    Coney, JER
    Sheppard, CGW
    Merdjani, S
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1996, 19 (06): : 369 - 381
  • [9] Experimental study on the effect of condensate water on the performance of split air conditioning system
    Yang, Hua
    Pei, Na
    Liu, Liansheng
    Fan, Man
    Qin, Yue
    ENERGY REPORTS, 2021, 7 : 840 - 851
  • [10] Thermal performance optimization of building floors under air-conditioning intermittent operation by numerical simulation
    Meng, Xi
    Du, Junfei
    Wang, Yating
    Gao, Yanna
    JOURNAL OF BUILDING PHYSICS, 2019, 43 (02) : 99 - 120