Numerical study on the thermal performance of water flow window fed with air-conditioning condensate

被引:6
|
作者
Chan, Lok Shun [1 ]
机构
[1] City Univ Hong Kong, Div Bldg Sci & Technol, Kowloon, Tat Chee Ave, Hong Kong, Peoples R China
关键词
Water flow window; Condensate recovery; Building energy simulation; ENERGY; CONSERVATION; SYSTEMS; UNIT; HOT;
D O I
10.1016/j.energy.2022.125633
中图分类号
O414.1 [热力学];
学科分类号
摘要
A water flow window (WFW) fed with potable water is deemed as an effective system for absorbing incoming heat energy through the glazing area of a window. In this study, condensate formed in an air-conditioning (A/C) system is applied in a WFW for reducing heat gain and electricity consumption of a building. There is no need to consume any potable water. Through building energy simulations and numerical computation, this study unveils that a fully air-conditioned office building operating under a subtropical climate can produce condensate of sufficient flow rate to absorb heat energy from the glazing panes of an A/C condensate fed WFW system. The surface temperature of an outer glazing pane in an A/C condensate fed WFW system can be dropped by 16.3 degrees C when compared to a Low-e glass window. Moreover, an A/C condensate fed WFW can offer better thermal performance than a conventional WFW. When comparing to a Low-e glass case, an A/C condensate fed WFW facing four different orientations (N, E, S & W) can give reduction percentages of transmitted heat gain ranging from 57.2% to 63.5%. This A/C condensate fed WFW system shows a promising performance and has good potential for real application in commercial buildings.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Research on Air-side Performance of Automobile Air-conditioning Parallel Flow Condenser
    Xiang, Liping
    Wang, Hanqing
    2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, : 3119 - +
  • [32] PERFORMANCE STUDY OF A SOLAR-POWERED AIR-CONDITIONING SYSTEM
    BONG, TY
    NG, KC
    TAY, AO
    SOLAR ENERGY, 1987, 39 (03) : 173 - 182
  • [33] A novel method to study on evaporative cooling air-conditioning performance
    Sun, ZY
    Tu, GB
    You, SJ
    Yang, J
    CRYOGENICS AND REFRIGERATION - PROCEEDINGS OF ICCR'2003, 2003, : 620 - 623
  • [34] An experimental study of the noise and the performance of cross-flow fans in room air-conditioning systems
    Koo, HM
    NOISE CONTROL ENGINEERING JOURNAL, 2000, 48 (02) : 41 - 47
  • [35] THERMAL ENERGY REQUIREMENTS OF AIR-CONDITIONING SYSTEMS
    LACKEY, ME
    MECHANICAL ENGINEERING, 1971, 93 (04) : 61 - &
  • [36] THERMAL ENERGY REQUIREMENTS OF AIR-CONDITIONING SYSTEMS
    LACKEY, ME
    JOURNAL OF ENGINEERING FOR POWER, 1971, 93 (02): : 172 - &
  • [37] Numerical study and optimization of the combined indirect evaporative air cooler for air-conditioning systems
    Anisimov, Sergey
    Pandelidis, Demis
    Danielewicz, Jan
    ENERGY, 2015, 80 : 452 - 464
  • [38] Numerical Study of Cross Flow Fan Performance in an Indoor Air Conditioning Unit
    Yet, New Mei
    Raghavan, Vijay R.
    Chinc, W. M.
    4TH INTERNATIONAL MEETING OF ADVANCES IN THERMOFLUIDS (IMAT 2011), PT 1 AND 2, 2012, 1440 : 314 - 323
  • [39] ECOMOMIC ASSESSMENT OF CHILLED WATER THERMAL STORAGE AND CONVENTIONAL AIR-CONDITIONING SYSTEMS
    Sebzali, M. J.
    Ameer, B.
    Hussain, H. J.
    TERRAGREEN 2012: CLEAN ENERGY SOLUTIONS FOR SUSTAINABLE ENVIRONMENT (CESSE), 2012, 18 : 1485 - 1495
  • [40] Study on the personal air-conditioning system considering human thermal adaptation
    Zhu, SW
    Kato, S
    Song, D
    Murakami, S
    Sudo, M
    PROCEEDINGS OF THE 4TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS 1 AND 2, 2003, : 393 - 401