Numerical study on the thermal performance of water flow window fed with air-conditioning condensate

被引:6
|
作者
Chan, Lok Shun [1 ]
机构
[1] City Univ Hong Kong, Div Bldg Sci & Technol, Kowloon, Tat Chee Ave, Hong Kong, Peoples R China
关键词
Water flow window; Condensate recovery; Building energy simulation; ENERGY; CONSERVATION; SYSTEMS; UNIT; HOT;
D O I
10.1016/j.energy.2022.125633
中图分类号
O414.1 [热力学];
学科分类号
摘要
A water flow window (WFW) fed with potable water is deemed as an effective system for absorbing incoming heat energy through the glazing area of a window. In this study, condensate formed in an air-conditioning (A/C) system is applied in a WFW for reducing heat gain and electricity consumption of a building. There is no need to consume any potable water. Through building energy simulations and numerical computation, this study unveils that a fully air-conditioned office building operating under a subtropical climate can produce condensate of sufficient flow rate to absorb heat energy from the glazing panes of an A/C condensate fed WFW system. The surface temperature of an outer glazing pane in an A/C condensate fed WFW system can be dropped by 16.3 degrees C when compared to a Low-e glass window. Moreover, an A/C condensate fed WFW can offer better thermal performance than a conventional WFW. When comparing to a Low-e glass case, an A/C condensate fed WFW facing four different orientations (N, E, S & W) can give reduction percentages of transmitted heat gain ranging from 57.2% to 63.5%. This A/C condensate fed WFW system shows a promising performance and has good potential for real application in commercial buildings.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Thermal Performance Study on a Sensible Cool Thermal Energy Storage System for Building Air-Conditioning Applications
    Muthaiyan, Kesavan
    Lakshmanan, Chidambaram
    Raj, Kaiwalya
    Sharma, Mangat Ram
    Narayanasamy, Rajamani
    Vellaichamy, Pandiyarajan
    Ramalingam, Velraj
    INTERNATIONAL JOURNAL OF PHOTOENERGY, 2021, 2021
  • [22] Enhancement of condensate water quantity and coefficient of performance of an air conditioning system: An experimental study
    Meher, Raghavarapu Satya
    Jaikumar, Sagari
    HEAT TRANSFER, 2021, 50 (05) : 4144 - 4151
  • [23] EXPERIMENTAL INVESTIGATION ON THERMAL PERFORMANCE OF NANOCOATED SURFACES FOR AIR-CONDITIONING APPLICATIONS
    Meikandan, Megaraj
    Malarmohan, Keppan
    Hemachandran, E.
    THERMAL SCIENCE, 2019, 23 (02): : 457 - 463
  • [24] Experimental analysis of the thermal stability of the pressure control method for a variable flow air-conditioning water system
    Zhao Tianyi
    Zhang Jili
    Ma Liangdong
    BUILDING AND ENVIRONMENT, 2013, 70 : 1 - 9
  • [25] Thermal performance analysis of small hermetic refrigeration and air-conditioning, compressors
    Kim, MH
    Bullard, CW
    JSME INTERNATIONAL JOURNAL SERIES B-FLUIDS AND THERMAL ENGINEERING, 2002, 45 (04) : 857 - 864
  • [26] Field study and numerical investigation on heating performance of air carrying energy radiant air-conditioning system in an office
    Peng, Pei
    Gong, Guangcai
    Deng, Xiaorui
    Liang, Chun
    Li, Wenqiang
    ENERGY AND BUILDINGS, 2020, 209
  • [27] PERFORMANCE EVALUATION OF AIR-CONDITIONING UNITS
    ALBASSAM, E
    MAHESHWARI, GP
    RENEWABLE ENERGY, 1994, 4 (07) : 873 - 878
  • [28] Monitoring the performance of air-conditioning plants
    Karki, Satu
    Hyvarinen, Juhani
    VTT Tiedotteita - Valtion Teknillinen Tutkimuskeskus, (1832):
  • [29] Numerical simulation and analysis of an air-conditioning condenser
    College of Energy and Power Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
    不详
    Huazhong Ligong Daxue Xuebao, 2007, 9 (42-44): : 42 - 44
  • [30] Numerical investigation on the thermal performance of double glazing air flow window with integrated blinds
    Movassag, Sirous Zeyninejad
    Zamzamian, Kamiar
    RENEWABLE ENERGY, 2020, 148 : 852 - 863