Total Keratometry Measured With a Swept-Source Optical Biometer Versus Anterior Keratometry: From Planning to Postoperative Results

被引:2
|
作者
Anjou, Mickael [1 ]
Brezin, Antoine [1 ]
Monnet, Dominique [1 ]
机构
[1] Cochin Hosp, AP HP, Dept Ophthalmol, 27 Rue Faubourg St Jacques, F-75014 Paris, France
关键词
POSTERIOR CORNEAL ASTIGMATISM; TORIC INTRAOCULAR LENSES; PREDICTION ACCURACY; POWER MEASUREMENTS; CATARACT-SURGERY; PHACOEMULSIFICATION;
D O I
10.3928/01913913-20230125-01
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare the influence of total keratometry (TK) versus anterior keratometry (K) measured with the swept-source optical biometer IOLMaster 700 (Carl Zeiss Meditec AG) on the planning of toric intraocular lenses (IOLs), and the error in predicted residual astigmatism (PRA).METHODS: This single-center retrospective study included 247 eyes of 180 patients. In eyes undergoing cataract surgery, the optimal toric IOL was calculated based on K or TK mea-sured with the IOLMaster 700. Two formulas were used to estimate IOL power: Holladay and Barrett Toric. Optimal cyl-inder power and alignment axis change induced by using TK versus K were reported. PRA by each calculation method was compared with manifest refractive astigmatism. Postopera-tive refractive astigmatism prediction error was calculated using vector analysis.RESULTS: The optimal toric IOL based on TK compared with K was different in 39.3% of cases with the Holladay formu-la and 31.6% of cases with the Barrett Toric formula. The use of TK rather than K reduced the centroid error in PRA when calculated with the Holladay formula (P < .001), but not when calculated with the Barrett Toric formula (P = .19). The against-the-rule astigmatism subgroup analysis with the Barrett Toric formula showed a statistically significant de-crease of centroid error in PRA with the use of TK compared with K (P = .01).CONCLUSIONS: TK compared with K measured with the IOL-Master 700 resulted in a change of optimal toric IOL in almost one-third of cases and decreased the error in PRA in patients with against-the-rule astigmatism.
引用
收藏
页码:257 / 265
页数:9
相关论文
共 37 条
  • [1] Comparing Standard Keratometry and Total Keratometry Before and After Myopic Corneal Refractive Surgery With a Swept-Source OCT Biometer
    Wang, Ziyang
    Song, Yanzheng
    Yang, Wenli
    Li, Dongjun
    Chen, Wei
    Zhao, Qi
    Liu, Qian
    Zhai, Changbin
    FRONTIERS IN MEDICINE, 2022, 9
  • [2] Prediction accuracy of standard and total keratometry by swept-source optical biometer for multifocal intraocular lens power calculation
    Hun Lee
    Jae Lim Chung
    Young Jun Kim
    Jae Yong Kim
    Hungwon Tchah
    Scientific Reports, 11
  • [3] Prediction accuracy of standard and total keratometry by swept-source optical biometer for multifocal intraocular lens power calculation
    Lee, Hun
    Chung, Jae Lim
    Kim, Young Jun
    Kim, Jae Yong
    Tchah, Hungwon
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [4] Differences Between Keratometry and Total Keratometry Measurements in a Large Dataset Obtained With a Modern Swept Source Optical Coherence Tomography Biometer
    Wendelstein, Jascha A.
    Hoffmann, Peter C.
    Hoffer, Kenneth J.
    Langenbucher, Achim
    Findl, Oliver
    Ruiss, Manuel
    Bolz, Matthias
    Riaz, Kamran M.
    Pantanelli, Seth M.
    Debellemaniere, Guillaume
    Gatinel, Damien
    Cooke, David L.
    Galzignato, Alice
    Yeo, Tun kuan
    Seiler, Theo G.
    Zinkernagel, Martin
    Savini, Giacomo
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2024, 260 : 102 - 114
  • [5] Lower refractive prediction accuracy of total keratometry using intraocular lens formulas loaded onto a swept-source optical biometer
    Yukitaka Danjo
    Reina Ohji
    Sayo Maeno
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2023, 261 : 137 - 146
  • [6] Lower refractive prediction accuracy of total keratometry using intraocular lens formulas loaded onto a swept-source optical biometer
    Danjo, Yukitaka
    Ohji, Reina
    Maeno, Sayo
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2023, 261 (01) : 137 - 146
  • [7] The Influence of Corneal Thickness on Surgically Induced Corneal Astigmatism Derived from Total Keratometry Measured by Anterior Segment Swept-Source OCT
    Zhao, Fangyu
    Yin, Yufan
    Pazo, Emmanuel Eric
    Tian, Fang
    Jiang, Yuanfeng
    Bu, Shaochong
    OPHTHALMOLOGY AND THERAPY, 2024, 13 (09) : 2381 - 2391
  • [8] Comparison of Keratometry Obtained by a Swept Source OCT-Based Biometer with a Standard Optical Biometer and Scheimpflug Imaging
    Asena, Leyla
    Akman, Ahmet
    Gungor, Sirel Gur
    Altinors, Dilek Dursun
    CURRENT EYE RESEARCH, 2018, 43 (07) : 882 - 888
  • [9] Repeatability of Keratometry Measurements with Swept-Source Optical Coherence Tomography in Normal Eyes
    Poulsen, Anne
    Cui, Amy Lu David
    Seeger, Catherine
    Lehman, Erik
    Scott, Ingrid U.
    Pantanelli, Seth
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)
  • [10] Total keratometry for toric intraocular lens calculation: comparison from two swept-source optical coherence tomography biometers
    Chai, Feiyan
    Ma, Jack X.
    Wang, Xiaogang
    Liu, Jiewei
    Jiang, Lin
    Wu, Wanmin
    Li, Junhong
    FRONTIERS IN MEDICINE, 2024, 10