Prediction accuracy of standard and total keratometry by swept-source optical biometer for multifocal intraocular lens power calculation

被引:9
|
作者
Lee, Hun [1 ]
Chung, Jae Lim [2 ]
Kim, Young Jun [2 ]
Kim, Jae Yong [1 ]
Tchah, Hungwon [1 ]
机构
[1] Univ Ulsan, Asan Med Ctr, Dept Ophthalmol, Coll Med, 88,Olymp Ro 43 Gil, Seoul 05505, South Korea
[2] Eyejun Ophthalm Clin, Seoul, South Korea
基金
新加坡国家研究基金会;
关键词
D O I
10.1038/s41598-021-84238-1
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
We aimed to compare the refractive outcomes of cataract surgery with diffractive multifocal intraocular lenses (IOLs) using standard keratometry (K) and total keratometry (TK). In this retrospective observational case series study, a total of 302 patients who underwent cataract surgery with multifocal IOL implantation were included. Predicted refractive outcomes were calculated based on the current standard formulas and a new formula developed for TK using K and TK, which were obtained from a swept-source optical biometer. At 2-month postoperatively, median absolute prediction errors (MedAEs) and proportion of eyes within +/- 0.50 diopters (D) of predicted postoperative spherical equivalent (SE) refraction were analyzed. There was no significant difference between MedAEs or proportion of eyes within +/- 0.50D of predicted refraction from K and TK in each formula. In TFNT00 and 839MP IOL cases, there was no difference between MedAEs from K and TK using any formula. In 829MP IOL cases, MedAE from TK was significantly larger than that from K in Barrett Universal II/Barrett TK Universal II (P=0.033). In 677MY IOL cases, MedAE from TK was significantly larger than that from K in Haigis (P=0.020) and Holladay 2 (P=0.006) formulas. In the subgroup analysis for IOL, there was no difference between the proportion of eyes within +/- 0.50 D of predicted refraction from K and TK using any formula. TFNT00 and 839MP IOLs were favorable with TK, with 677MY IOL with K and 829MP IOL being in a neutral position, which necessitates the study that investigates the accuracy of the new TK technology.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Prediction accuracy of standard and total keratometry by swept-source optical biometer for multifocal intraocular lens power calculation
    Hun Lee
    Jae Lim Chung
    Young Jun Kim
    Jae Yong Kim
    Hungwon Tchah
    Scientific Reports, 11
  • [2] Accuracy of intraocular lens power calculation formulas using a swept-source optical biometer
    Kim, Se Young
    Lee, Seung Hyun
    Kim, Na Rae
    Chin, Hee Seung
    Jung, Ji Won
    PLOS ONE, 2020, 15 (01):
  • [3] Lower refractive prediction accuracy of total keratometry using intraocular lens formulas loaded onto a swept-source optical biometer
    Yukitaka Danjo
    Reina Ohji
    Sayo Maeno
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2023, 261 : 137 - 146
  • [4] Lower refractive prediction accuracy of total keratometry using intraocular lens formulas loaded onto a swept-source optical biometer
    Danjo, Yukitaka
    Ohji, Reina
    Maeno, Sayo
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2023, 261 (01) : 137 - 146
  • [5] Comparison of formula accuracy for intraocular lens power calculation based on measurements by a swept-source optical coherence tomography optical biometer
    Savini, Giacomo
    Hoffer, Kenneth J.
    Balducci, Nicole
    Barboni, Piero
    Schiano-Lomoriello, Domenico
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (01): : 27 - 33
  • [6] Accuracy of Total Corneal Power Calculation for Multifocal Toric Intraocular Lens Implantation: Swept-Source OCT-Based Biometer vs Scheimpflug Tomographer
    Choi, Ayoung
    Kwon, Hyunggoo
    Jeon, Sohee
    JOURNAL OF REFRACTIVE SURGERY, 2021, 37 (10) : 686 - +
  • [7] Accuracy of intraocular lens calculation formulas based on swept-source OCT biometer in cataract patients with phakic intraocular lens
    Zeng, Zongsheng
    Zhu, Meiyi
    Zhang, Guangbin
    BMC OPHTHALMOLOGY, 2024, 24 (01)
  • [8] Total keratometry for toric intraocular lens calculation: comparison from two swept-source optical coherence tomography biometers
    Chai, Feiyan
    Ma, Jack X.
    Wang, Xiaogang
    Liu, Jiewei
    Jiang, Lin
    Wu, Wanmin
    Li, Junhong
    FRONTIERS IN MEDICINE, 2024, 10
  • [9] Total Keratometry Measured With a Swept-Source Optical Biometer Versus Anterior Keratometry: From Planning to Postoperative Results
    Anjou, Mickael
    Brezin, Antoine
    Monnet, Dominique
    JOURNAL OF REFRACTIVE SURGERY, 2023, 39 (04) : 257 - 265
  • [10] Prediction Accuracy of Total Keratometry Compared to Standard Keratometry Using Different Intraocular Lens Power Formulas
    Fabian, Ekkehard
    Wehner, Wolfram
    JOURNAL OF REFRACTIVE SURGERY, 2019, 35 (06) : 362 - 369