Total Keratometry Measured With a Swept-Source Optical Biometer Versus Anterior Keratometry: From Planning to Postoperative Results

被引:2
|
作者
Anjou, Mickael [1 ]
Brezin, Antoine [1 ]
Monnet, Dominique [1 ]
机构
[1] Cochin Hosp, AP HP, Dept Ophthalmol, 27 Rue Faubourg St Jacques, F-75014 Paris, France
关键词
POSTERIOR CORNEAL ASTIGMATISM; TORIC INTRAOCULAR LENSES; PREDICTION ACCURACY; POWER MEASUREMENTS; CATARACT-SURGERY; PHACOEMULSIFICATION;
D O I
10.3928/01913913-20230125-01
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare the influence of total keratometry (TK) versus anterior keratometry (K) measured with the swept-source optical biometer IOLMaster 700 (Carl Zeiss Meditec AG) on the planning of toric intraocular lenses (IOLs), and the error in predicted residual astigmatism (PRA).METHODS: This single-center retrospective study included 247 eyes of 180 patients. In eyes undergoing cataract surgery, the optimal toric IOL was calculated based on K or TK mea-sured with the IOLMaster 700. Two formulas were used to estimate IOL power: Holladay and Barrett Toric. Optimal cyl-inder power and alignment axis change induced by using TK versus K were reported. PRA by each calculation method was compared with manifest refractive astigmatism. Postopera-tive refractive astigmatism prediction error was calculated using vector analysis.RESULTS: The optimal toric IOL based on TK compared with K was different in 39.3% of cases with the Holladay formu-la and 31.6% of cases with the Barrett Toric formula. The use of TK rather than K reduced the centroid error in PRA when calculated with the Holladay formula (P < .001), but not when calculated with the Barrett Toric formula (P = .19). The against-the-rule astigmatism subgroup analysis with the Barrett Toric formula showed a statistically significant de-crease of centroid error in PRA with the use of TK compared with K (P = .01).CONCLUSIONS: TK compared with K measured with the IOL-Master 700 resulted in a change of optimal toric IOL in almost one-third of cases and decreased the error in PRA in patients with against-the-rule astigmatism.
引用
收藏
页码:257 / 265
页数:9
相关论文
共 37 条
  • [31] Automated detection of inflammatory cells in whole anterior chamber of a uveitis mouse from swept-source optical coherence tomography images
    Choi, Woo June
    Pepple, Kathryn L.
    Wang, Ruikang K.
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XX, 2016, 9697
  • [32] Agreement of Anterior Segment Parameters Obtained From Swept-Source Fourier-Domain and Time-Domain Anterior Segment Optical Coherence Tomography
    Chansangpetch, Sunee
    Nguyen, Anwell
    Mora, Marta
    Badr, Mai
    He, Mingguang
    Porco, Travis C.
    Lin, Shan C.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (03) : 1554 - 1561
  • [33] Retinal Capillary Plexus Pattern and Density from Fovea to Periphery Measured in Healthy Eyes with Swept-Source Optical Coherence Tomography Angiography
    Carlo Lavia
    Pedro Mecê
    Marco Nassisi
    Sophie Bonnin
    Jennifer Marie-Louise
    Aude Couturier
    Ali Erginay
    Ramin Tadayoni
    Alain Gaudric
    Scientific Reports, 10
  • [34] Retinal Capillary Plexus Pattern and Density from Fovea to Periphery Measured in Healthy Eyes with Swept-Source Optical Coherence Tomography Angiography
    Lavia, Carlo
    Mece, Pedro
    Nassisi, Marco
    Bonnin, Sophie
    Marie-Louise, Jennifer
    Couturier, Aude
    Erginay, Ali
    Tadayoni, Ramin
    Gaudric, Alain
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [35] Comparison of test-retest variabilities of anterior segment parameters measured by two anterior segment swept-source optical coherence tomography (SS-OCT)-the ANTERION and the CASIA II
    Chan, Poemen Pui Man
    Lai, Gilda
    Leung, Christopher Kai-Shun
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)
  • [36] A New Parameter for Predicting the Postoperative Intraocular Lens Position: Angle-to-Angle Depth Assessed with Swept-Source Fourier-Domain Anterior Segment Optical Coherence Tomography
    Goto, So
    Ohnuma, Kazuhiko
    Noda, Toru
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [37] INTERNAL LIMITING MEMBRANE PEELING VERSUS NONPEELING TO PREVENT EPIRETINAL MEMBRANE DEVELOPMENT IN PRIMARY RHEGMATOGENOUS RETINAL DETACHMENT A Swept-Source Optical Coherence Tomography Study With a New Postoperative Classification System
    Arias, Luis
    Padron-Perez, Noel
    Flores-Moreno, Ignacio
    Giralt, Lena
    Cobos, Estefania
    Lorenzo, Daniel
    Garcia-Bru, Pere
    Dias, Bruno
    Caminal, Josep M.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2020, 40 (07): : 1286 - 1298