Total Keratometry Measured With a Swept-Source Optical Biometer Versus Anterior Keratometry: From Planning to Postoperative Results

被引:2
|
作者
Anjou, Mickael [1 ]
Brezin, Antoine [1 ]
Monnet, Dominique [1 ]
机构
[1] Cochin Hosp, AP HP, Dept Ophthalmol, 27 Rue Faubourg St Jacques, F-75014 Paris, France
关键词
POSTERIOR CORNEAL ASTIGMATISM; TORIC INTRAOCULAR LENSES; PREDICTION ACCURACY; POWER MEASUREMENTS; CATARACT-SURGERY; PHACOEMULSIFICATION;
D O I
10.3928/01913913-20230125-01
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare the influence of total keratometry (TK) versus anterior keratometry (K) measured with the swept-source optical biometer IOLMaster 700 (Carl Zeiss Meditec AG) on the planning of toric intraocular lenses (IOLs), and the error in predicted residual astigmatism (PRA).METHODS: This single-center retrospective study included 247 eyes of 180 patients. In eyes undergoing cataract surgery, the optimal toric IOL was calculated based on K or TK mea-sured with the IOLMaster 700. Two formulas were used to estimate IOL power: Holladay and Barrett Toric. Optimal cyl-inder power and alignment axis change induced by using TK versus K were reported. PRA by each calculation method was compared with manifest refractive astigmatism. Postopera-tive refractive astigmatism prediction error was calculated using vector analysis.RESULTS: The optimal toric IOL based on TK compared with K was different in 39.3% of cases with the Holladay formu-la and 31.6% of cases with the Barrett Toric formula. The use of TK rather than K reduced the centroid error in PRA when calculated with the Holladay formula (P < .001), but not when calculated with the Barrett Toric formula (P = .19). The against-the-rule astigmatism subgroup analysis with the Barrett Toric formula showed a statistically significant de-crease of centroid error in PRA with the use of TK compared with K (P = .01).CONCLUSIONS: TK compared with K measured with the IOL-Master 700 resulted in a change of optimal toric IOL in almost one-third of cases and decreased the error in PRA in patients with against-the-rule astigmatism.
引用
收藏
页码:257 / 265
页数:9
相关论文
共 37 条
  • [21] Simulation of toric intraocular lens results: Manual "keratomtry versus dual-zone automated keratometry from an integrated biometer
    Hill, Warren
    Osher, Robert
    Cooke, David
    Solomon, Kerry
    Sandoval, Helga
    Salas-Cervantes, Rosario
    Potvin, Richard
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (12): : 2181 - 2187
  • [22] Comparison of anterior segment measurements obtained using a swept-source optical coherence tomography biometer and a Scheimpflug-Placido tomographer
    Lu, Weicong
    Li, Yue
    Savini, Giacomo
    Song, Benhao
    Hu, Qingjie
    Wang, Qinmei
    Bao, Fangjun
    Huang, Jinhai
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (03): : 298 - 304
  • [23] The Precision of a New Anterior Segment Optical Coherence Tomographer and Its Comparison With a Swept-Source OCT-Based Optical Biometer in Patients With Cataract
    Wang, Qinmei
    Chen, Min
    Ning, Rui
    Savini, Giacomo
    Wang, Yiran
    Zhang, Tianjiao
    Lin, Xuanqiao
    Chen, Xin
    Huang, Jinhai
    JOURNAL OF REFRACTIVE SURGERY, 2021, 37 (09) : 616 - +
  • [24] Characteristics of ciliary muscle profile in high myopes measured by swept-source anterior segment optical coherence tomography
    Kwok, Hiu Yin
    Kwok, Hoi Yee
    Ng, Tsz Nok
    Leung, Tsz-wing
    Kang, Byung Soo
    Kee, Chea-su
    PLOS ONE, 2023, 18 (11):
  • [25] The 10,000 Eyes Study: Analysis of Keratometry, Abulafia-Koch regression transformation, and Biometric Eye Parameters Obtained With Swept-Source Optical Coherence Tomography
    Wendelstein, Jascha A.
    Reifeltshammer, Sophia A.
    Cooke, David L.
    Hirnschall, Nino
    Hoffmann, Peter C.
    Langenbucher, Achim
    Bolz, Matthias
    Riaz, Kamran M.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2023, 245 : 44 - 60
  • [26] Repeatability and Interobserver Reproducibility of a Swept-Source Optical Coherence Tomography for Measurements of Anterior, Posterior, and Total Corneal Power
    Lei, Chak Seng
    Lin, Xuanqiao
    Ning, Rui
    Yu, Jinjin
    Huang, Xiaomin
    Li, Kexin
    Wang, Yiran
    Savini, Giacomo
    Schiano-Lomoriello, Domenico
    Zhou, Xingtao
    Huang, Jinhai
    OPHTHALMOLOGY AND THERAPY, 2023, 12 (06) : 3263 - 3279
  • [27] Repeatability and Interobserver Reproducibility of a Swept-Source Optical Coherence Tomography for Measurements of Anterior, Posterior, and Total Corneal Power
    Chak Seng Lei
    Xuanqiao Lin
    Rui Ning
    Jinjin Yu
    Xiaomin Huang
    Kexin Li
    Yiran Wang
    Giacomo Savini
    Domenico Schiano-Lomoriello
    Xingtao Zhou
    Jinhai Huang
    Ophthalmology and Therapy, 2023, 12 : 3263 - 3279
  • [28] Repeatability and Agreement of a Swept-Source Optical Coherence Tomography-Based Biometer IOLMaster 700 Versus a Scheimpflug Imaging-Based Biometer AL-Scan in Cataract Patients
    Chan, Tommy C. Y.
    Wan, Kelvin H.
    Tang, Fang Yao
    Wang, Yu Meng
    Yu, Marco
    Cheung, Carol
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2020, 46 (01): : 35 - 45
  • [29] Repeatability and agreement in optical biometry of a new swept-source optical coherence tomography-based biometer versus partial coherence interferometry and optical low-coherence reflectometry
    Kunert, Kathleen S.
    Peter, Monika
    Blum, Marcus
    Haigis, Wolfgang
    Sekundo, Walter
    Schuetze, Juliane
    Bueehren, Tobias
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (01): : 76 - 83
  • [30] Evaluation of the Temporal Anterior Chamber Depth Measured with Anterior Segment Swept-Source Optical Coherence Tomography and its Association with the Van-Herick Test and Angle Measurements
    Lavinsky, Fabio
    Silva Swarovsky, Ariadne Peres
    Lindenmeyer, Rodrigo Leivas
    Meyer Campos de Almeida, Rafaela Correa
    da Silva, Anais
    Santiago Gomes, Gustavo Afonso
    Lavinsky, Daniel
    Silveira, Victoria Dazevedo
    Oliveira, Monica
    Lavinsky, Jaco
    Picceti, Egidio
    Pakter, Helena Messinger
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)