Dynamic Contrast-enhanced CT Lymphangiography to Quantify Thoracic Duct Lymphatic Flow

被引:1
|
作者
Molloi, Sabee [1 ]
Polivka, Alesh R. [1 ]
Zhao, Yixiao [1 ]
Redmond, Jonas [3 ]
Itkin, Maxim [4 ]
Antunes, Ines [1 ]
Yu, Zhaoxia [2 ]
机构
[1] Univ Calif Irvine, Dept Radiol Sci, Med Sci 1,B-140, Irvine, CA 92697 USA
[2] Univ Calif Irvine, Dept Stat, Med Sci 1,B-140, Irvine, CA 92697 USA
[3] Univ Calif San Diego, Dept Radiol Sci, San Diego, CA USA
[4] Univ Penn, Dept Radiol, Philadelphia, PA USA
关键词
MR LYMPHANGIOGRAPHY; VENOUS-PRESSURE; GADOFOSVESET; DIAGNOSIS; FAILURE;
D O I
10.1148/radiol.230959
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: CT lymphangiography has been used to image the lymphatic anatomy and assess lymphatic abnormalities. There is, however, a need to develop a method for quantification of lymphatic flow rate in the thoracic duct (TD). Purpose: To develop and validate a TD lymphatic flow measurement technique using dynamic contrast -enhanced CT lymphangiography. Materials and Methods: Lymphatic flow rate was measured with two techniques: a first -pass analysis technique based on a single compartment model and a thresholding technique distinguishing between opacified and nonopacified voxels within the TD. The measurements were validated in a swine animal model between November 2021 and September 2022. CT images were acquired at 100 kV and 200 mA using a fast -pitched helical scan mode covering the entire TD following contrast material injection into the bilateral inguinal lymph nodes. Two helical CT scans, acquired at the base and peak contrast enhancement of the TD, were used to measure lymphatic flow rate. A US flow probe surgically placed around the TD provided the reference standard measurement. CT lymphatic flow measurements were compared with the reference US flow probe measurements using regression and Bland -Altman analysis. Repeatability was determined using repeated flow measurements within approximately 10 minutes of each other. Results: Eleven swine (10 male; mean weight, 43.6 kg +/- 2.6 [SD]) were evaluated with 71 dynamic CT acquisitions. The lymphatic flow rates measured using the first -pass analysis and thresholding techniques were highly correlated with the reference US flow probe measurements (r = 0.99 and 0.91, respectively) and showed good agreement with the reference standard, with Bland -Altman analysis showing small mean differences of 0.04 and 0.05 mL/min, respectively. The first -pass analysis and thresholding techniques also showed good agreement for repeated flow measurements (r = 0.94 and 0.90, respectively), with small mean differences of 0.09 and 0.03 mL/min, respectively. Conclusion: The first -pass analysis and thresholding techniques could be used to accurately and noninvasively quantify TD lymphatic flow using dynamic contrast -enhanced CT lymphangiography.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Characterization of mesothelioma and tissues present in contrast-enhanced thoracic CT scans
    Corson, Neal
    Sensakovic, William F.
    Straus, Christopher
    Starkey, Adam
    Armato, Samuel G., III
    MEDICAL PHYSICS, 2011, 38 (02) : 942 - 947
  • [42] Dynamic contrast-enhanced MR lymphangiography: feasibility of using ferumoxytol in patients with chronic kidney disease
    Yekeler, Ensar
    Krishnamurthy, Ganesh
    Smith, Christopher L.
    Escobar, Fernando A.
    Pinto, Erin
    Rapp, Jordan B.
    Otero, Hansel J.
    White, Ammie M.
    Dori, Yoav
    Biko, David M.
    EUROPEAN RADIOLOGY, 2022, 32 (04) : 2564 - 2571
  • [43] Combining non-contrast enhanced magnetic resonance thoracic ductography with vascular contrast-enhanced computed tomography to identify the canine thoracic duct
    Kutara, Kenji
    Kanda, Teppei
    Maeta, Noritaka
    Mochizuki, Yohei
    Ono, Fumiko
    Itoh, Yoshiki
    Asanuma, Taketoshi
    OPEN VETERINARY JOURNAL, 2020, 10 (01) : 68 - 73
  • [44] The spectrum of imaging manifestations of Gorham–Stout disease: a novel dynamic contrast-enhanced MR lymphangiography
    Yuna Lee
    Seunghyun Lee
    Saebeom Hur
    Yun Soo Jeong
    Dong In Suh
    Jangsup Moon
    Man Jin Kim
    Young Hun Choi
    Jung-Eun Cheon
    Orphanet Journal of Rare Diseases, 18
  • [45] Dynamic contrast-enhanced MR lymphangiography: feasibility of using ferumoxytol in patients with chronic kidney disease
    Ensar Yekeler
    Ganesh Krishnamurthy
    Christopher L. Smith
    Fernando A. Escobar
    Erin Pinto
    Jordan B. Rapp
    Hansel J. Otero
    Ammie M. White
    Yoav Dori
    David M. Biko
    European Radiology, 2022, 32 : 2564 - 2571
  • [46] DIAGNOSIS AND LOCALIZATION OF LACERATION OF THE THORACIC-DUCT - USEFULNESS OF LYMPHANGIOGRAPHY AND CT
    SACHS, PB
    ZELCH, MG
    RICE, TW
    GEISINGER, MA
    RISIUS, B
    LAMMERT, GK
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 157 (04) : 703 - 705
  • [47] Dynamic Contrast-Enhanced CT and MRI for Pulmonary Nodule Assessment
    Ohno, Yoshiharu
    Nishio, Mizuho
    Koyama, Hisanobu
    Miura, Sachiko
    Yoshikawa, Takeshi
    Matsumoto, Sumiaki
    Sugimura, Kazuro
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 202 (03) : 515 - 529
  • [48] Role of contrast-enhanced dynamic CT in the diagnosis of active tuberculoma
    Tateishi, U
    Kusumoto, M
    Akiyama, Y
    Kishi, F
    Nishimura, M
    Moriyama, N
    CHEST, 2002, 122 (04) : 1280 - 1284
  • [49] The Use of Non-ionic Contrast Agent for Lymphangiography and Embolization of the Thoracic Duct
    Mohammed H. Alomari
    Anna Lillis
    Cindy Kerr
    Jane W. Newburger
    Luis Quinonez
    Ahmad I. Alomari
    CardioVascular and Interventional Radiology, 2019, 42 : 481 - 483
  • [50] MR lymphangiography: Visualization of thoracic duct without contrast agent: Initial experience
    Miyazaki, M
    Hayashi, S
    Shimada, M
    Tsubuku, M
    Ito, K
    Kaneko, I
    RADIOLOGY, 1999, 213P : 196 - 196