Dynamic Contrast-enhanced CT Lymphangiography to Quantify Thoracic Duct Lymphatic Flow

被引:1
|
作者
Molloi, Sabee [1 ]
Polivka, Alesh R. [1 ]
Zhao, Yixiao [1 ]
Redmond, Jonas [3 ]
Itkin, Maxim [4 ]
Antunes, Ines [1 ]
Yu, Zhaoxia [2 ]
机构
[1] Univ Calif Irvine, Dept Radiol Sci, Med Sci 1,B-140, Irvine, CA 92697 USA
[2] Univ Calif Irvine, Dept Stat, Med Sci 1,B-140, Irvine, CA 92697 USA
[3] Univ Calif San Diego, Dept Radiol Sci, San Diego, CA USA
[4] Univ Penn, Dept Radiol, Philadelphia, PA USA
关键词
MR LYMPHANGIOGRAPHY; VENOUS-PRESSURE; GADOFOSVESET; DIAGNOSIS; FAILURE;
D O I
10.1148/radiol.230959
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: CT lymphangiography has been used to image the lymphatic anatomy and assess lymphatic abnormalities. There is, however, a need to develop a method for quantification of lymphatic flow rate in the thoracic duct (TD). Purpose: To develop and validate a TD lymphatic flow measurement technique using dynamic contrast -enhanced CT lymphangiography. Materials and Methods: Lymphatic flow rate was measured with two techniques: a first -pass analysis technique based on a single compartment model and a thresholding technique distinguishing between opacified and nonopacified voxels within the TD. The measurements were validated in a swine animal model between November 2021 and September 2022. CT images were acquired at 100 kV and 200 mA using a fast -pitched helical scan mode covering the entire TD following contrast material injection into the bilateral inguinal lymph nodes. Two helical CT scans, acquired at the base and peak contrast enhancement of the TD, were used to measure lymphatic flow rate. A US flow probe surgically placed around the TD provided the reference standard measurement. CT lymphatic flow measurements were compared with the reference US flow probe measurements using regression and Bland -Altman analysis. Repeatability was determined using repeated flow measurements within approximately 10 minutes of each other. Results: Eleven swine (10 male; mean weight, 43.6 kg +/- 2.6 [SD]) were evaluated with 71 dynamic CT acquisitions. The lymphatic flow rates measured using the first -pass analysis and thresholding techniques were highly correlated with the reference US flow probe measurements (r = 0.99 and 0.91, respectively) and showed good agreement with the reference standard, with Bland -Altman analysis showing small mean differences of 0.04 and 0.05 mL/min, respectively. The first -pass analysis and thresholding techniques also showed good agreement for repeated flow measurements (r = 0.94 and 0.90, respectively), with small mean differences of 0.09 and 0.03 mL/min, respectively. Conclusion: The first -pass analysis and thresholding techniques could be used to accurately and noninvasively quantify TD lymphatic flow using dynamic contrast -enhanced CT lymphangiography.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Use of Contrast-Enhanced Ultrasound to Determine Thoracic Duct Patency
    Mejia, Erika J.
    Otero, Hansel J.
    Smith, Christopher L.
    Shipman, Molly
    Liu, Mandi
    Pinto, Erin
    DeWitt, Aaron
    Rome, Jonathan J.
    Dori, Yoav
    Biko, David M.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2020, 31 (10) : 1670 - 1674
  • [22] Comparison of Dynamic Contrast-Enhanced MRI and Dynamic Contrast-Enhanced CT Biomarkers in Bladder Cancer
    Naish, J. H.
    McGrath, D. M.
    Bains, L. J.
    Passera, K.
    Roberts, C.
    Watson, Y.
    Cheung, S.
    Taylor, M. B.
    Logue, J. P.
    Buckley, D. L.
    Tessier, J.
    Young, H.
    Waterton, J. C.
    Parker, G. J. M.
    MAGNETIC RESONANCE IN MEDICINE, 2011, 66 (01) : 219 - 226
  • [23] Direct contrast-enhanced magnetic resonance lymphangiography in the diagnosis of persistent occult chylous effusion leak after thoracic duct embolization
    Kiang, Sharon C.
    Ahmed, Khwaja A.
    Barnes, Samual
    Abou-Zamzam, Ahmed M., Jr.
    Tomihama, Roger T.
    JOURNAL OF VASCULAR SURGERY-VENOUS AND LYMPHATIC DISORDERS, 2019, 7 (02) : 251 - 257
  • [24] Feasibility of contrast-enhanced ultrasound in confirming intranodal needle position for dynamic contrast-enhanced magnetic resonance lymphangiography in children
    Fung, Kin Fen Kevin
    Chen, Hay-son Robin
    Ng, Wing Kei Carol
    Che, Ka Yee Jojo
    Poon, Mei Yu
    Lun, Kin Shing
    Kan, Yee Ling Elaine
    PEDIATRIC RADIOLOGY, 2023, 53 (10) : 2137 - 2143
  • [25] Feasibility of contrast-enhanced ultrasound in confirming intranodal needle position for dynamic contrast-enhanced magnetic resonance lymphangiography in children
    Kin Fen Kevin Fung
    Hay-son Robin Chen
    Wing Kei Carol Ng
    Ka Yee Jojo Che
    Mei Yu Poon
    Kin Shing Lun
    Yee Ling Elaine Kan
    Pediatric Radiology, 2023, 53 : 2137 - 2143
  • [26] Assessment of Tumor Blood Flow Distribution by Dynamic Contrast-Enhanced CT
    Koh, T. S.
    Shi, W.
    Thng, C. H.
    Ho, J. T. S.
    Khoo, J. B. K.
    Cheong, D. L. H.
    Lim, T. C. C.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2013, 32 (08) : 1504 - 1514
  • [27] Lymphangiography and Contrast-Enhanced Lymphosonography for the Diagnosis of Chyluria
    Liu, Hsien-Tzu
    Wang, Hsin-Kai
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2022, 218 (01) : 181 - 181
  • [28] Single-Center Experience With Dynamic Contrast-Enhanced Magnetic Resonance Lymphangiography for Diagnosing Lymphatic Disorders and Guiding Percutaneous Embolization
    Ahn, Yura
    Koo, Hyun Jung
    Choe, Jooae
    Chu, Hee Ho
    Yang, Dong Hyun
    Kang, Joon-Won
    Shin, Ji Hoon
    JOURNAL OF KOREAN MEDICAL SCIENCE, 2024, 39 (39)
  • [29] Dynamic contrast-enhanced magnetic resonance lymphangiography: a simple algorithm for image interpretation
    Morales-Tisnes, Tatiana
    De Leon-Benedetti, Laura S.
    Ramirez-Suarez, Karen I.
    Noor, Abass M.
    Chauhan, Ankita
    Otero, Hansel J.
    Biko, David M.
    PEDIATRIC RADIOLOGY, 2024,
  • [30] Opacification of the Distal Thoracic Duct on CT: Not by Lymphatic Resorption of Contrast Material Reply
    Branstetter, Barton F.
    Liu, Ming-Eng
    Escott, Edward J.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (06) : W695 - W695