Dynamic Contrast-enhanced CT Lymphangiography to Quantify Thoracic Duct Lymphatic Flow

被引:1
|
作者
Molloi, Sabee [1 ]
Polivka, Alesh R. [1 ]
Zhao, Yixiao [1 ]
Redmond, Jonas [3 ]
Itkin, Maxim [4 ]
Antunes, Ines [1 ]
Yu, Zhaoxia [2 ]
机构
[1] Univ Calif Irvine, Dept Radiol Sci, Med Sci 1,B-140, Irvine, CA 92697 USA
[2] Univ Calif Irvine, Dept Stat, Med Sci 1,B-140, Irvine, CA 92697 USA
[3] Univ Calif San Diego, Dept Radiol Sci, San Diego, CA USA
[4] Univ Penn, Dept Radiol, Philadelphia, PA USA
关键词
MR LYMPHANGIOGRAPHY; VENOUS-PRESSURE; GADOFOSVESET; DIAGNOSIS; FAILURE;
D O I
10.1148/radiol.230959
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: CT lymphangiography has been used to image the lymphatic anatomy and assess lymphatic abnormalities. There is, however, a need to develop a method for quantification of lymphatic flow rate in the thoracic duct (TD). Purpose: To develop and validate a TD lymphatic flow measurement technique using dynamic contrast -enhanced CT lymphangiography. Materials and Methods: Lymphatic flow rate was measured with two techniques: a first -pass analysis technique based on a single compartment model and a thresholding technique distinguishing between opacified and nonopacified voxels within the TD. The measurements were validated in a swine animal model between November 2021 and September 2022. CT images were acquired at 100 kV and 200 mA using a fast -pitched helical scan mode covering the entire TD following contrast material injection into the bilateral inguinal lymph nodes. Two helical CT scans, acquired at the base and peak contrast enhancement of the TD, were used to measure lymphatic flow rate. A US flow probe surgically placed around the TD provided the reference standard measurement. CT lymphatic flow measurements were compared with the reference US flow probe measurements using regression and Bland -Altman analysis. Repeatability was determined using repeated flow measurements within approximately 10 minutes of each other. Results: Eleven swine (10 male; mean weight, 43.6 kg +/- 2.6 [SD]) were evaluated with 71 dynamic CT acquisitions. The lymphatic flow rates measured using the first -pass analysis and thresholding techniques were highly correlated with the reference US flow probe measurements (r = 0.99 and 0.91, respectively) and showed good agreement with the reference standard, with Bland -Altman analysis showing small mean differences of 0.04 and 0.05 mL/min, respectively. The first -pass analysis and thresholding techniques also showed good agreement for repeated flow measurements (r = 0.94 and 0.90, respectively), with small mean differences of 0.09 and 0.03 mL/min, respectively. Conclusion: The first -pass analysis and thresholding techniques could be used to accurately and noninvasively quantify TD lymphatic flow using dynamic contrast -enhanced CT lymphangiography.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Quantification of Thoracic Lymphatic Flow Patterns Using Dynamic Contrast-enhanced MR Lymphangiography
    Zheng, Qiang
    Itkin, Maxim
    Fan, Yong
    RADIOLOGY, 2020, 296 (01) : 202 - 207
  • [2] Intranodal dynamic contrast-enhanced CT lymphangiography and dynamic contrast-enhanced MR lymphangiography in microminipig
    Tanahashi, Yukichi
    Shoda, Shinichi
    Kawada, Hiroshi
    Ando, Tomohiro
    Nagata, Shoma
    Takasu, Masaki
    Hyodo, Fuminori
    Goshima, Satoshi
    Mori, Takashi
    Matsuo, Masayuki
    EUROPEAN RADIOLOGY, 2023, 33 (05) : 3165 - 3171
  • [3] Intranodal dynamic contrast-enhanced CT lymphangiography and dynamic contrast-enhanced MR lymphangiography in microminipig
    Yukichi Tanahashi
    Shinichi Shoda
    Hiroshi Kawada
    Tomohiro Ando
    Shoma Nagata
    Masaki Takasu
    Fuminori Hyodo
    Satoshi Goshima
    Takashi Mori
    Masayuki Matsuo
    European Radiology, 2023, 33 : 3165 - 3171
  • [4] Contrast-enhanced CT Lymphangiography for Various Central Lymphatic Disorders
    Ahn, Yura
    Koo, Hyun Jung
    Choe, Jooae
    Lee, Jong Eun
    Yang, Dong Hyun
    Kang, Joon-Won
    Shin, Ji Hoon
    RADIOGRAPHICS, 2024, 44 (12)
  • [5] A case series of thoracic dynamic contrast-enhanced MR lymphangiography: technique and applications
    Xie, Cheng
    Stoddart, Catriona
    McIntyre, Anthony
    StNoble, Victoria
    Peschl, Heiko
    Benamore, Rachel
    BJR CASE REPORTS, 2020, 6 (03):
  • [6] Dynamic Contrast-Enhanced Magnetic Resonance Lymphangiography and Lymphatic Interventions for Pediatric Patients with Various Lymphatic Diseases
    Ahn, Yura
    Koo, Hyun Jung
    Yoon, Hee Mang
    Choe, Jooae
    Joo, Eun-Young
    Song, Myung-Hee
    Yang, Dong Hyun
    Kang, Joon-Won
    Shin, Ji Hoon
    LYMPHATIC RESEARCH AND BIOLOGY, 2023, 21 (02) : 141 - 151
  • [7] Dynamic contrast-enhanced magnetic resonance lymphangiography
    Karen I. Ramirez-Suarez
    Luis O. Tierradentro-Garcia
    Christopher L. Smith
    Ganesh Krishnamurthy
    Fernando A. Escobar
    Hansel J. Otero
    Jordan B. Rapp
    Yoav Dori
    David M. Biko
    Pediatric Radiology, 2022, 52 : 285 - 294
  • [8] Dynamic contrast-enhanced magnetic resonance lymphangiography
    Ramirez-Suarez, Karen I.
    Tierradentro-Garcia, Luis O.
    Smith, Christopher L.
    Krishnamurthy, Ganesh
    Escobar, Fernando A.
    Otero, Hansel J.
    Rapp, Jordan B.
    Dori, Yoav
    Biko, David M.
    PEDIATRIC RADIOLOGY, 2022, 52 (02) : 285 - 294
  • [9] Dynamic contrast-enhanced magnetic resonance lymphangiography of chylous leak before surgical ligation of the thoracic duct: case report
    Tawfik, Ahmed Mohamed
    Batouty, Nihal
    Sersar, Sameh
    Awad, Gehad
    Alaaeldin, Fetoh
    Elshalkamy, Mohamed
    Sobh, Donia
    INDIAN JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2023, 39 (01) : 64 - 67
  • [10] Dynamic contrast-enhanced magnetic resonance lymphangiography of chylous leak before surgical ligation of the thoracic duct: case report
    Ahmed Mohamed Tawfik
    Nihal Batouty
    Sameh Sersar
    Gehad Awad
    Fetoh Alaaeldin
    Mohamed Elshalkamy
    Donia Sobh
    Indian Journal of Thoracic and Cardiovascular Surgery, 2023, 39 : 64 - 67