Pulmonary Artery Dual-Lumen Cannulation Versus Two Cannula Percutaneous Extracorporeal Membrane Oxygenation Configuration in Right Ventricular Failure

被引:5
|
作者
Ritter, Lindsay A. [1 ]
Haj Bakri, Mouaz [2 ]
Fahey, Heather C. [3 ]
Sanghavi, Kavya K. [4 ]
Kallur, Akhil [5 ]
Bien-Aime, Fred [5 ]
Sallam, Tariq [6 ]
Alassar, Aiman [7 ]
Balsara, Keki [7 ]
Kitahara, Hiroto [8 ]
MacGillivray, Thomas E. [7 ]
Zaaqoq, Akram M. [1 ,5 ]
机构
[1] Georgetown Univ, MedStar Washington Hosp Ctr, Dept Crit Care Med, Washington, DC USA
[2] Univ Florida, Div Hosp Med, Shands Hosp, Gainesville, FL USA
[3] Georgetown Univ, MedStar Washington Hosp Ctr, Dept Cardiol, Washington, DC USA
[4] MedStar Hlth Res Inst, Hyattsville, MD USA
[5] Georgetown Univ, MedStar Washington Hosp Ctr, Dept Med, Washington, DC USA
[6] Brown Univ, Div Pulm Crit Care & Sleep Med, Providence, RI USA
[7] Georgetown Univ, MedStar Washington Hosp Ctr, Dept Cardiac Surg, Washington, DC USA
[8] Univ Chicago Med, Dept Cardiothorac Surg, Chicago, IL USA
关键词
right ventricular assist device; extracorporeal membrane oxygenation; right ventricular failure; cardiogenic shock; ASSIST DEVICE; SUPPORT; COMPLICATIONS; TANDEMHEART; SHOCK;
D O I
10.1097/MAT.0000000000001950
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Refractory right ventricular failure has significant morbidity and mortality. Extracorporeal membrane oxygenation is indicated when medical interventions are deemed ineffective. However, it is still being determined if one configuration is better. We conducted a retrospective analysis of our institutional experience comparing the peripheral veno-pulmonary artery (V-PA) configuration versus the dual-lumen cannula with the tip in the pulmonary artery (C-PA). The analysis of a cohort of 24 patients (12 patients in each group). There was no difference in survival after hospital discharge (58.3% in the C-PA group compared to 41.7% in the V-PA group, p = 0.4). Among the C-PA group, there was a statistically significant shorter ICU length of stay (23.5 days [interquartile range {IQR} = 19-38.5] vs. 43 days [IQR = 30-50], p = 0.043) and duration of mechanical ventilation (7.5 days [IQR = 4.5-9.5] compared to (16.5 days [IQR = 9.5-22.5], p = 0.006) in the V-PA group. In the C-PA group, there were lower incidents of bleeding (33.33% vs. 83.33%, p =0.036) and combined ischemic events (0 vs. 41.67%, p = 0.037). In our single-center experience, the C-PA configuration might have a better outcome than the V-PA one. Further studies are needed to confirm our findings.
引用
收藏
页码:766 / 773
页数:8
相关论文
共 50 条
  • [41] Transesophageal Echocardiography-Guided Technique for Extracorporeal Membrane Oxygenation Dual-Lumen Catheter Placement
    Dolch, Michael E.
    Frey, Lorenz
    Buerkle, Martin A.
    Weig, Thomas
    Wassilowsky, Dietmar
    Irlbeck, Michael
    ASAIO JOURNAL, 2011, 57 (04) : 341 - 343
  • [42] Outcomes with the Tandem Protek Duo Dual-Lumen Percutaneous Right Ventricular Assist Device
    Ravichandran, Ashwin K.
    Baran, David A.
    Stelling, Kelly
    Cowger, Jennifer A.
    Salerno, Christopher T.
    ASAIO JOURNAL, 2018, 64 (04) : 570 - 572
  • [43] Optimal Methods to Secure Extracorporeal Membrane Oxygenation Bicaval Dual-Lumen Cannulae: What Works?
    Tignanelli, Christopher J.
    Weinberg, Allison
    Napolitano, Lena M.
    ASAIO JOURNAL, 2019, 65 (06) : 628 - 630
  • [44] Ambulatory Extracorporeal Membrane Oxygenation with Right Atrium to Pulmonary Artery Cannulation Through Hemisternotomy for Longterm Support
    Song, T. H.
    Baker, J. N.
    Melnitchouk, S. I.
    Sundt, T. M.
    Garcia, J. P.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2014, 33 (04): : S249 - S249
  • [45] Optimal Endovascular Methods for Placement of Bicaval Dual-Lumen Cannulae for Venovenous Extracorporeal Membrane Oxygenation
    Teman, Nicholas R.
    Haft, Jonathan W.
    Napolitano, Lena M.
    ASAIO JOURNAL, 2013, 59 (04) : 442 - 447
  • [46] Improved Flow Dynamics of Extracorporeal Membrane Oxygenation via Design Modification of Dual-Lumen Cannulas
    Azimi, Marjan
    Liao, Sam
    Vatani, Ashkan
    Burrell, Aidan
    Gregory, Shaun D.
    ASAIO JOURNAL, 2022, 68 (11) : 1358 - 1366
  • [47] Percutaneous venopulmonary artery extracorporeal membrane oxygenation for right heart failure after left ventricular assist device insertion
    Joshi, Yashutosh
    Bories, Marie-Cecile
    Aissaoui, Nadia
    Grinda, Jean-Michel
    Bel, Alain
    Latremouille, Christian
    Jouan, Jerome
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2021, 33 (06) : 978 - 985
  • [48] Unusual Complication of a Right Ventricular Support-Extracorporeal Membrane Oxygenation Cannula
    Unger, Erin D.
    Sweis, Ranya N.
    Bharat, Ankit
    JAMA CARDIOLOGY, 2021, 6 (06) : 723 - 724
  • [49] Use of Venovenous Extracorporeal Membrane Oxygenation and an Atrial Septostomy for Pulmonary and Right Ventricular Failure
    Camboni, Daniele
    Akay, Begum
    Sassalos, Peter
    Toomasian, John M.
    Haft, Jonathan W.
    Bartlett, Robert H.
    Cook, Keith E.
    ANNALS OF THORACIC SURGERY, 2011, 91 (01): : 144 - 149
  • [50] Veno-right ventricular cannulation reduces recirculation in extracorporeal membrane oxygenation
    Lindstrom, S. J.
    Mennen, M. T.
    Rosenfeldt, F. L.
    Salmonsen, R. F.
    PERFUSION-UK, 2012, 27 (06): : 464 - 469