Pulmonary Artery Dual-Lumen Cannulation Versus Two Cannula Percutaneous Extracorporeal Membrane Oxygenation Configuration in Right Ventricular Failure

被引:5
|
作者
Ritter, Lindsay A. [1 ]
Haj Bakri, Mouaz [2 ]
Fahey, Heather C. [3 ]
Sanghavi, Kavya K. [4 ]
Kallur, Akhil [5 ]
Bien-Aime, Fred [5 ]
Sallam, Tariq [6 ]
Alassar, Aiman [7 ]
Balsara, Keki [7 ]
Kitahara, Hiroto [8 ]
MacGillivray, Thomas E. [7 ]
Zaaqoq, Akram M. [1 ,5 ]
机构
[1] Georgetown Univ, MedStar Washington Hosp Ctr, Dept Crit Care Med, Washington, DC USA
[2] Univ Florida, Div Hosp Med, Shands Hosp, Gainesville, FL USA
[3] Georgetown Univ, MedStar Washington Hosp Ctr, Dept Cardiol, Washington, DC USA
[4] MedStar Hlth Res Inst, Hyattsville, MD USA
[5] Georgetown Univ, MedStar Washington Hosp Ctr, Dept Med, Washington, DC USA
[6] Brown Univ, Div Pulm Crit Care & Sleep Med, Providence, RI USA
[7] Georgetown Univ, MedStar Washington Hosp Ctr, Dept Cardiac Surg, Washington, DC USA
[8] Univ Chicago Med, Dept Cardiothorac Surg, Chicago, IL USA
关键词
right ventricular assist device; extracorporeal membrane oxygenation; right ventricular failure; cardiogenic shock; ASSIST DEVICE; SUPPORT; COMPLICATIONS; TANDEMHEART; SHOCK;
D O I
10.1097/MAT.0000000000001950
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Refractory right ventricular failure has significant morbidity and mortality. Extracorporeal membrane oxygenation is indicated when medical interventions are deemed ineffective. However, it is still being determined if one configuration is better. We conducted a retrospective analysis of our institutional experience comparing the peripheral veno-pulmonary artery (V-PA) configuration versus the dual-lumen cannula with the tip in the pulmonary artery (C-PA). The analysis of a cohort of 24 patients (12 patients in each group). There was no difference in survival after hospital discharge (58.3% in the C-PA group compared to 41.7% in the V-PA group, p = 0.4). Among the C-PA group, there was a statistically significant shorter ICU length of stay (23.5 days [interquartile range {IQR} = 19-38.5] vs. 43 days [IQR = 30-50], p = 0.043) and duration of mechanical ventilation (7.5 days [IQR = 4.5-9.5] compared to (16.5 days [IQR = 9.5-22.5], p = 0.006) in the V-PA group. In the C-PA group, there were lower incidents of bleeding (33.33% vs. 83.33%, p =0.036) and combined ischemic events (0 vs. 41.67%, p = 0.037). In our single-center experience, the C-PA configuration might have a better outcome than the V-PA one. Further studies are needed to confirm our findings.
引用
收藏
页码:766 / 773
页数:8
相关论文
共 50 条
  • [31] Pulmonary artery cannulation during venovenous extracorporeal membrane oxygenation: An alternative to manage refractory hypoxemia and right ventricular dysfunction
    Rojas-Velasco, Gustavo
    Carmona-Levario, Patricia
    Manzur-Sandoval, Daniel
    Lazcano-Diaz, Emmanuel
    Damas-de Los Santos, Felix
    RESPIRATORY MEDICINE CASE REPORTS, 2022, 38
  • [32] Subclavian Insertion of the Bicaval Dual Lumen Cannula for Venovenous Extracorporeal Membrane Oxygenation
    Shafii, Alexis E.
    McCurry, Kenneth R.
    ANNALS OF THORACIC SURGERY, 2012, 94 (02): : 663 - 665
  • [33] Direct complications of the Avalon bicaval dual-lumen cannula in respiratory extracorporeal membrane oxygenation (ECMO): Single-center experience
    Rubino, Antonio
    Vuylsteke, Alain
    Jenkins, David P.
    Fowles, Jo-anne
    Hockings, Lisen
    Valchanov, Kamen
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2014, 37 (10): : 741 - 747
  • [34] Three Cases of Severe Pulmonary Embolism After Dual-Lumen Extracorporeal Membrane Oxygenation Catheter Removal Reply
    Barrett, Nicholas A.
    Camporota, Luigi
    Retter, Andrew
    CRITICAL CARE MEDICINE, 2016, 44 (06) : E449 - E450
  • [35] Large Dual-Lumen Extracorporeal Membrane Oxygenation Cannulas Are Associated with More Intracranial Hemorrhage
    Mazzeffi, Michael
    Kon, Zachary
    Menaker, Jay
    Johnson, Daniel M.
    Parise, Orlando
    Gelsomino, Sandro
    Lorusso, Roberto
    Herr, Daniel
    ASAIO JOURNAL, 2019, 65 (07) : 674 - 677
  • [36] Use of Bicaval Dual-Lumen Catheter for Adult Venovenous Extracorporeal Membrane Oxygenation DISCUSSION
    Hines, Michael
    Dr Ibrahimiye
    Dr Zwischenberger
    Wozniak, Thomas
    ANNALS OF THORACIC SURGERY, 2011, 91 (06): : 1769 - 1769
  • [37] Fluid Flow Analysis of Neonatal Dual-Lumen Cannulas for Venovenous Extracorporeal Membrane Oxygenation
    Sawka, Danielle M.
    Su, Yunxing
    Monteagudo, Julie
    Zenit, Roberto
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2024, 146 (02):
  • [38] Novel percutaneous dual-lumen cannula-based right ventricular assist device provides effective support for refractory right ventricular failure after left ventricular assist device implantation
    Salna, Michael
    Garan, A. Reshad
    Kirtane, Ajay J.
    Karmpaliotis, Dimitrios
    Green, Phil
    Takayama, Hiroo
    Sanchez, Joseph
    Kurlansky, Paul
    Yuzefpolskaya, Melana
    Colombo, Paolo C.
    Naka, Yoshifumi
    Takeda, Koji
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2020, 30 (04) : 499 - 506
  • [39] Extracorporeal Membrane Oxygenation For Right Ventricular Failure And Hypoxia
    Narang, N.
    Poston, J. T.
    Shah, A. P.
    Kress, J. P.
    Maitland-Gomberg, M.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2014, 189
  • [40] Concurrent veno-pulmonary extracorporeal membrane oxygenation cannulation with ProtekDuo parallel to an in situ veno-pulmonary single-lumen cannula
    Maybauer, Marc O.
    Rackauskas, Mindaugas
    Brewer, J. Michael
    Becker, Torben K.
    PERFUSION-UK, 2024,