Pulmonary Artery Dual-Lumen Cannulation Versus Two Cannula Percutaneous Extracorporeal Membrane Oxygenation Configuration in Right Ventricular Failure

被引:5
|
作者
Ritter, Lindsay A. [1 ]
Haj Bakri, Mouaz [2 ]
Fahey, Heather C. [3 ]
Sanghavi, Kavya K. [4 ]
Kallur, Akhil [5 ]
Bien-Aime, Fred [5 ]
Sallam, Tariq [6 ]
Alassar, Aiman [7 ]
Balsara, Keki [7 ]
Kitahara, Hiroto [8 ]
MacGillivray, Thomas E. [7 ]
Zaaqoq, Akram M. [1 ,5 ]
机构
[1] Georgetown Univ, MedStar Washington Hosp Ctr, Dept Crit Care Med, Washington, DC USA
[2] Univ Florida, Div Hosp Med, Shands Hosp, Gainesville, FL USA
[3] Georgetown Univ, MedStar Washington Hosp Ctr, Dept Cardiol, Washington, DC USA
[4] MedStar Hlth Res Inst, Hyattsville, MD USA
[5] Georgetown Univ, MedStar Washington Hosp Ctr, Dept Med, Washington, DC USA
[6] Brown Univ, Div Pulm Crit Care & Sleep Med, Providence, RI USA
[7] Georgetown Univ, MedStar Washington Hosp Ctr, Dept Cardiac Surg, Washington, DC USA
[8] Univ Chicago Med, Dept Cardiothorac Surg, Chicago, IL USA
关键词
right ventricular assist device; extracorporeal membrane oxygenation; right ventricular failure; cardiogenic shock; ASSIST DEVICE; SUPPORT; COMPLICATIONS; TANDEMHEART; SHOCK;
D O I
10.1097/MAT.0000000000001950
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Refractory right ventricular failure has significant morbidity and mortality. Extracorporeal membrane oxygenation is indicated when medical interventions are deemed ineffective. However, it is still being determined if one configuration is better. We conducted a retrospective analysis of our institutional experience comparing the peripheral veno-pulmonary artery (V-PA) configuration versus the dual-lumen cannula with the tip in the pulmonary artery (C-PA). The analysis of a cohort of 24 patients (12 patients in each group). There was no difference in survival after hospital discharge (58.3% in the C-PA group compared to 41.7% in the V-PA group, p = 0.4). Among the C-PA group, there was a statistically significant shorter ICU length of stay (23.5 days [interquartile range {IQR} = 19-38.5] vs. 43 days [IQR = 30-50], p = 0.043) and duration of mechanical ventilation (7.5 days [IQR = 4.5-9.5] compared to (16.5 days [IQR = 9.5-22.5], p = 0.006) in the V-PA group. In the C-PA group, there were lower incidents of bleeding (33.33% vs. 83.33%, p =0.036) and combined ischemic events (0 vs. 41.67%, p = 0.037). In our single-center experience, the C-PA configuration might have a better outcome than the V-PA one. Further studies are needed to confirm our findings.
引用
收藏
页码:766 / 773
页数:8
相关论文
共 50 条
  • [21] Percutaneous dual-outflow extracorporeal membrane oxygenation support in secondary right ventricular failure
    Hecker, Florian
    Keller, Harald
    Vasa-Nicotera, Mariuca
    Iken, Sonja
    Holubec, Tomas
    JTCVS TECHNIQUES, 2022, 13 : 125 - 127
  • [22] Percutaneous Pulmonary Artery Cannulation to Treat Acute Secondary Right Heart Failure While on Veno-venous Extracorporeal Membrane Oxygenation
    Ivins-O'Keefe, Kelly M.
    Cahill, Michael S.
    Mielke, Arthur R.
    Sobieszczyk, Michal J.
    Sams, Valerie G.
    Mason, Phillip E.
    Read, Matthew D.
    ASAIO JOURNAL, 2022, 68 (12) : 1483 - 1489
  • [23] Use of Bicaval Dual-Lumen Catheter for Adult Venovenous Extracorporeal Membrane Oxygenation
    Javidfar, Jeffrey
    Brodie, Daniel
    Wang, Dongfang
    Ibrahimiye, Ali N.
    Yang, Jonathan
    Zwischenberger, Joseph B.
    Sonett, Joshua
    Bacchetta, Matthew
    ANNALS OF THORACIC SURGERY, 2011, 91 (06): : 1763 - 1769
  • [24] Echocardiography-Guided Dual-Lumen Venovenous Extracorporeal Membrane Oxygenation Cannula Placement in the ICU-A Retrospective Review
    Griffee, Matthew J.
    Zimmerman, Joshua M.
    McKellar, Stephen H.
    Tonna, Joseph E.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2020, 34 (03) : 698 - 705
  • [25] Dual lumen cannulation and mobilization of patients with venovenous extracorporeal membrane oxygenation
    Noe, Christian
    Rottmann, Felix A.
    Bemtgen, Xavier
    Supady, Alexander
    Wengenmayer, Tobias
    Staudacher, Dawid L.
    ARTIFICIAL ORGANS, 2023, 47 (10) : 1654 - 1662
  • [26] A case of successful bedside cannulation with a bicaval dual-lumen cannula guided by transthoracic echocardiography and mobile X-ray for veno-venous extracorporeal membrane oxygenation
    Tatsuki Uemura
    Keigo Sekihara
    Tatsunori Ogawa
    Kota Ishizuka
    Hiyori Katsuoka
    Minato Kawaguchi
    Wataru Matsuda
    Ryo Sasaki
    Tatsuya Okamoto
    Akio Kimura
    Journal of Artificial Organs, 2023, 26 : 165 - 167
  • [27] Thrombosis of the Right Internal Jugular Vein is Not a Contraindication to Ambulatory Veno-Venous Extracorporeal Membrane Oxygenation with a Bicaval Dual-Lumen, Single Cannula System
    Kronfli, Anthony P.
    Pasrija, Chetan
    Shah, Aakash
    Ghoreishi, Mehrdad
    Garcia, Jose P.
    Pham, Si M.
    Sanchez, Pablo G.
    Kon, Zachary N.
    HEART SURGERY FORUM, 2016, 19 (06): : E282 - E283
  • [28] A case of successful bedside cannulation with a bicaval dual-lumen cannula guided by transthoracic echocardiography and mobile X-ray for veno-venous extracorporeal membrane oxygenation
    Uemura, Tatsuki
    Sekihara, Keigo
    Ogawa, Tatsunori
    Ishizuka, Kota
    Katsuoka, Hiyori
    Kawaguchi, Minato
    Matsuda, Wataru
    Sasaki, Ryo
    Okamoto, Tatsuya
    Kimura, Akio
    JOURNAL OF ARTIFICIAL ORGANS, 2023, 26 (02) : 165 - 167
  • [29] Pulmonary artery cannulation to enhance extracorporeal membrane oxygenation management in acute cardiac failure
    Lorusso, Roberto
    Raffa, Giuseppe Maria
    Heuts, Samuel
    Lo Coco, Valeria
    Meani, Paolo
    Natour, Ehsan
    Bidar, Elham
    Delnoij, Thijs
    Loforte, Antonio
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2020, 30 (02) : 215 - 222
  • [30] Veno-venous extracorporeal membrane oxygenation using an innovative dual-lumen cannula following implantation of a total artificial heart
    Youdle, Jemma
    Penn, Sarah
    Maunz, Olaf
    Simon, Andre