Pulmonary Artery Dual-Lumen Cannulation Versus Two Cannula Percutaneous Extracorporeal Membrane Oxygenation Configuration in Right Ventricular Failure

被引:5
|
作者
Ritter, Lindsay A. [1 ]
Haj Bakri, Mouaz [2 ]
Fahey, Heather C. [3 ]
Sanghavi, Kavya K. [4 ]
Kallur, Akhil [5 ]
Bien-Aime, Fred [5 ]
Sallam, Tariq [6 ]
Alassar, Aiman [7 ]
Balsara, Keki [7 ]
Kitahara, Hiroto [8 ]
MacGillivray, Thomas E. [7 ]
Zaaqoq, Akram M. [1 ,5 ]
机构
[1] Georgetown Univ, MedStar Washington Hosp Ctr, Dept Crit Care Med, Washington, DC USA
[2] Univ Florida, Div Hosp Med, Shands Hosp, Gainesville, FL USA
[3] Georgetown Univ, MedStar Washington Hosp Ctr, Dept Cardiol, Washington, DC USA
[4] MedStar Hlth Res Inst, Hyattsville, MD USA
[5] Georgetown Univ, MedStar Washington Hosp Ctr, Dept Med, Washington, DC USA
[6] Brown Univ, Div Pulm Crit Care & Sleep Med, Providence, RI USA
[7] Georgetown Univ, MedStar Washington Hosp Ctr, Dept Cardiac Surg, Washington, DC USA
[8] Univ Chicago Med, Dept Cardiothorac Surg, Chicago, IL USA
关键词
right ventricular assist device; extracorporeal membrane oxygenation; right ventricular failure; cardiogenic shock; ASSIST DEVICE; SUPPORT; COMPLICATIONS; TANDEMHEART; SHOCK;
D O I
10.1097/MAT.0000000000001950
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Refractory right ventricular failure has significant morbidity and mortality. Extracorporeal membrane oxygenation is indicated when medical interventions are deemed ineffective. However, it is still being determined if one configuration is better. We conducted a retrospective analysis of our institutional experience comparing the peripheral veno-pulmonary artery (V-PA) configuration versus the dual-lumen cannula with the tip in the pulmonary artery (C-PA). The analysis of a cohort of 24 patients (12 patients in each group). There was no difference in survival after hospital discharge (58.3% in the C-PA group compared to 41.7% in the V-PA group, p = 0.4). Among the C-PA group, there was a statistically significant shorter ICU length of stay (23.5 days [interquartile range {IQR} = 19-38.5] vs. 43 days [IQR = 30-50], p = 0.043) and duration of mechanical ventilation (7.5 days [IQR = 4.5-9.5] compared to (16.5 days [IQR = 9.5-22.5], p = 0.006) in the V-PA group. In the C-PA group, there were lower incidents of bleeding (33.33% vs. 83.33%, p =0.036) and combined ischemic events (0 vs. 41.67%, p = 0.037). In our single-center experience, the C-PA configuration might have a better outcome than the V-PA one. Further studies are needed to confirm our findings.
引用
收藏
页码:766 / 773
页数:8
相关论文
共 50 条
  • [1] A Dual-Lumen Percutaneous Cannula for Managing Refractory Right Ventricular Failure
    Badu, Bernice
    Cain, Michael T.
    Durham, Lucian A.
    Joyce, Lyle D.
    Sundararajan, Sakthi
    Gaglianello, Nunzio
    Ishizawar, David
    Saltzberg, Mitchell
    Mohammed, Asim
    Joyce, David L.
    ASAIO JOURNAL, 2020, 66 (08) : 915 - 921
  • [2] Comparison of the Avalon Dual-Lumen Cannula with Conventional Cannulation Technique for Venovenous Extracorporeal Membrane Oxygenation
    Kuhl, Thomas
    Michels, Guido
    Pfister, Roman
    Wendt, Stefanie
    Langebartels, Georg
    Wahlers, Thorsten
    THORACIC AND CARDIOVASCULAR SURGEON, 2015, 63 (08): : 653 - 662
  • [3] A Dual-Lumen Bicaval Cannula for Venovenous Extracorporeal Membrane Oxygenation
    Tipograf, Yuliya
    Gannon, Whitney D.
    Foley, Neal M.
    Hozain, Ahmed
    Ukita, Rei
    Warhoover, Matthew
    McMaster, William
    Nesbitt, Jonathan C.
    Shah, Ashish S.
    Bacchetta, Matthew
    ANNALS OF THORACIC SURGERY, 2020, 109 (04): : 1047 - 1053
  • [4] Ambulatory femoral venovenous extracorporeal membrane oxygenation with a dual-lumen cannula
    Orozco-Hernandez, Erik J.
    Munoz-Largacha, Juan A.
    Lusby, Megan
    Hoopes, Charles W.
    JTCVS TECHNIQUES, 2021, 9 : 199 - 201
  • [5] Alternative venous access sites for dual-lumen extracorporeal membrane oxygenation cannulation
    Schoeberl, Armin-Kai
    Staudacher, Dawid
    Kawashima, Mitsuaki
    Fischer, Courtney
    Cypel, Marcelo
    Buchtele, Nina
    Staudinger, Thomas
    Aigner, Clemens
    Hoetzenecker, Konrad
    Schweiger, Thomas
    INTERDISCIPLINARY CARDIOVASCULAR AND THORACIC SURGERY, 2024, 38 (04):
  • [6] Bicaval dual-lumen cannula for venovenous extracorporeal membrane oxygenation: Avalon© cannula in childhood disease
    Berdajs, D.
    PERFUSION-UK, 2015, 30 (03): : 182 - 186
  • [7] Bedside Emergency Percutaneous Extracorporeal Membrane Oxygenator with Bicaval Dual-Lumen Cannula
    Serraino, Giuseppe Filiberto
    Jiritano, Federica
    Rossi, Michele
    Mastroroberto, Pasquale
    HEART SURGERY FORUM, 2018, 21 (04): : E290 - E293
  • [8] Echo-Guided Insertion of a Dual-Lumen Cannula for Venovenous Extracorporeal Membrane Oxygenation
    Cianchi, Giovanni
    Lazzeri, Chiara
    Bonizzoli, Manuela
    Batacchi, Stefano
    Peris, Adriano
    ASAIO JOURNAL, 2019, 65 (04) : 414 - 416
  • [9] Avalon© Bicaval Dual-Lumen Cannula for Venovenous Extracorporeal Membrane Oxygenation: Survey of Cannula Use in France
    Chimot, Loic
    Marque, Sophie
    Gros, Antoine
    Gacouin, Arnaud
    Lavoue, Sylvain
    Camus, Christophe
    Le Tulzo, Yves
    ASAIO JOURNAL, 2013, 59 (02) : 157 - 161
  • [10] Venovenous cannulation for extracorporeal membrane oxygenation using a bicaval dual-lumen catheter in neonates
    Lazar, David A.
    Cass, Darrell L.
    Olutoye, Oluyinka O.
    Kim, Eugene S.
    Welty, Stephen E.
    Fernandes, Caraciolo J.
    Lee, Timothy C.
    JOURNAL OF PEDIATRIC SURGERY, 2012, 47 (02) : 430 - 434