Failure experiment on CFRP-strengthened prestressed concrete cylinder pipe with broken wires

被引:20
|
作者
Zhai, Kejie [1 ,2 ]
Fang, Hongyuan [1 ]
Li, Bin [1 ]
Guo, Chengchao [2 ]
Yang, Kangjian [1 ]
Du, Xueming [1 ]
Du, Mingrui [1 ]
Wang, Niannian [1 ]
机构
[1] Zhengzhou Univ, Yellow River Lab, Zhengzhou 450001, Peoples R China
[2] Sun Yat Sen Univ, Sch Civil Engn, Guangzhou 510275, Peoples R China
基金
中国国家自然科学基金;
关键词
Prestressed concrete cylinder pipe (PCCP); Broken wires; Carbon fiber reinforced polymer (CFRP); Strain gauging; Failure experiment; COATING DELAMINATION; RADIAL TENSION; PERFORMANCE; PCCP;
D O I
10.1016/j.tust.2023.105032
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The prestressed concrete cylinder pipe (PCCP) has been used widely in hydraulic engineering. However, due to hydrogen embrittlement and corrosion, the prestressing wires in PCCP can break and cause pipe failure. In this study, a retrofitting technique of using externally bonded carbon fiber reinforced polymer (CFRP) to repair PCCP was proposed. The technique is particularly useful when shutting down water is not possible. The proposed strategy was evaluated by using a full-scale PCCP with a 2.8 m inside diameter loaded with internal water pressure. First, the PCCP strains before and after repair were compared under different internal pressures. In the presence of CFRP, the strains near the broken wires significantly decreased under the same internal pressure, and the carrying capacity of the PCCP increased. PCCPs with 13 %, 15 %, and 18 % wire breakage ratios were then evaluated and compared. The strain in each material increased with increasing wire breakage ratio, and the maximum strain in CFRP was observed at the location of wire breakage. Considering the PCCP with 18 % wire breakage ratio, the section 2300 mm from the pipe end was in the linear state under an internal pressure of 0-0.9 MPa, and the PCCP reached its serviceability and elastic limit states when the internal pressure increased to about 1.0 MPa and 1.2 MPa, respectively. Finally, when the internal water pressure was increased to 1.27 MPa, which was higher than the internal design pressure of 1.12 MPa, the PCCP failed due to the rupture of CFRP.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Full-scale experiment and numerical simulation of prestressed concrete cylinder pipe with broken wires strengthened by prestressed CFRP
    Zhai, Kejie
    Fang, Hongyuan
    Guo, Chengchao
    Ni, Pengpeng
    Wu, Hanying
    Wang, Fuming
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2021, 115
  • [2] Mechanical properties of CFRP-strengthened prestressed concrete cylinder pipe based on multi-field coupling
    Zhai, Kejie
    Fang, Hongyuan
    Guo, Chengchao
    Fu, Bing
    Ni, Pengpeng
    Ma, Huihuan
    He, Hang
    Wang, Fuming
    THIN-WALLED STRUCTURES, 2021, 162 (162)
  • [3] Failure analysis of a prestressed concrete cylinder pipe under clustered broken wires by FEM
    Dong, Xiaonong
    Dou, Tiesheng
    Cheng, Bingqing
    Zhao, Lijun
    STRUCTURES, 2021, 33 : 3284 - 3297
  • [4] Mechanical behavior of prestressed concrete cylinder pipe strengthened by prestressed CFRP subject to secondary load
    Zhai, Kejie
    Wang, Kaidong
    Hu, Deqiang
    Fang, Hongyuan
    Wang, Niannian
    Li, Bin
    Du, Xueming
    Xue, Binghan
    ADVANCES IN STRUCTURAL ENGINEERING, 2025,
  • [5] Experimental and simulation study on PCCP with broken wires strengthened by prestressed CFRP
    Zhai K.
    Fang H.
    Guo C.
    Ni P.
    Fu B.
    Li B.
    Shuili Xuebao/Journal of Hydraulic Engineering, 2021, 52 (06): : 739 - 749
  • [6] Experimental study on the influence of scattered broken wires on the structural performance of prestressed concrete cylinder pipe
    Dong, Xiaonong
    Dou, Tiesheng
    Dong, Peng
    Su, Yan
    Li, Yanlong
    Ning, Jinghua
    Wei, Jichun
    Li, Kangping
    Cheng, Bingqing
    STRUCTURES, 2023, 47 : 52 - 62
  • [7] Analytical Model for CFRP-Strengthened Prestressed Concrete Girders Subject to Cyclic Loading
    Carneiro, Ronaldson J. de F. M.
    Melo, Guilherme S. S. de A.
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2011, 15 (05) : 871 - 874
  • [8] Mechanical properties of prestressed concrete cylinder pipe with broken wires using distributed fiber optic sensors
    Li, Kangping
    Li, Yanlong
    Dong, Peng
    Wang, Zuorong
    Dou, Tiesheng
    Ning, Jinghua
    Dong, Xiaonong
    Si, Zheng
    Wang, Jing
    ENGINEERING FAILURE ANALYSIS, 2022, 141
  • [9] CFRP liner quality control for repair of prestressed concrete cylinder pipe
    Allan, A.
    Carr, H.
    CHALLENGES, OPPORTUNITIES AND SOLUTIONS IN STRUCTURAL ENGINEERING AND CONSTRUCTION, 2010, : 623 - +
  • [10] Using EPS and CFRP liner to strengthen prestressed concrete cylinder pipe
    Zhai, Kejie
    Fang, Hongyuan
    Guo, Chengchao
    Li, Bin
    Wang, Niannian
    Yang, Kangjian
    Zhang, Xijun
    Du, Xueming
    Di, Danyang
    CONSTRUCTION AND BUILDING MATERIALS, 2024, 412