Image-guided navigation system for minimally invasive total hip arthroplasty (MITHA) using an improved position-sensing marker

被引:5
|
作者
Xie, Xianzhong [1 ]
Zhu, Mingzhu [1 ]
He, Bingwei [1 ]
Xu, Jie [2 ]
机构
[1] Fuzhou Univ, Sch Mech Engn, Fuzhou 350108, Fujian, Peoples R China
[2] Fujian Prov Hosp, Dept Orthoped Surg, Fuzhou 350013, Fujian, Peoples R China
基金
中国国家自然科学基金;
关键词
Surgery navigation; Minimally invasive total hip arthroplasty; Tracking; Point-based registration; Position-sensing marker; SURGICAL NAVIGATION; DYNAMIC NAVIGATION; POSE ESTIMATION; ACCURACY; TRACKING; REGISTRATION; PLACEMENT; TOOL;
D O I
10.1007/s11548-023-02861-x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
PurposeMinimally invasive total hip arthroplasty (MITHA) is a treatment for hip arthritis, and it causes less tissue trauma, blood loss, and recovery time. However, the limited incision makes it difficult for surgeons to perceive the instruments' location and orientation. Computer-assisted navigation systems can help improve the medical outcome of MITHA. Directly applying existing navigation systems for MITHA, however, suffers from problems of bulky fiducial marker, severe feature-loss, multiple instruments tracking confusion, and radiation exposure. To tackle these problems, we propose an image-guided navigation system for MITHA using a novel position-sensing marker.MethodsA position-sensing marker is proposed to serve as the fiducial marker with high-density and multi-fold ID tags. It results in less feature span and enables the use of ID for each feature, overcoming the problem of bulky fiducial markers and multiple instruments tracking confusion. And the marker can be recognized even when a large part of locating features is obscured. As for the elimination of intraoperative radiation exposure, we propose a point-based method to achieve patient-image registration based on anatomical landmarks.ResultsQuantitative experiments are conducted to evaluate the feasibility of our system. The accuracy of instrument positioning is achieved at 0.33 +/- 0.18 mm, and that of patient-image registration is achieved at 0.79 +/- 0.15 mm. And qualitative experiments are also performed, verifying that our system can be used in compact surgical spatial volume and can address severe feature-loss and tracking confusion problems. In addition, our system does not require any intraoperative medical scans.ConclusionExperimental results indicate that our proposed system can assist surgeons without larger space occupations, radiation exposure, and extra incision, showing its potential application value in MITHA.
引用
收藏
页码:2155 / 2166
页数:12
相关论文
共 50 条
  • [41] Intraoperative measurement of acetabular component position using imageless navigation during revision total hip arthroplasty
    Mei, Xin Yu
    Etemad-Rezaie, Ali
    Safir, Oleg A.
    Gross, Allan E.
    Kuzyk, Paul R.
    CANADIAN JOURNAL OF SURGERY, 2021, 64 (04) : E442 - E448
  • [42] Image-guided removal of deeply impacted mandibular third molar using a navigation system
    Takeda, Atsushi
    Iwai, Toshinori
    Sugiyama, Satomi
    Ohashi, Nobuhide
    Kitajima, Hiroaki
    Yajima, Yasuharu
    Hirota, Makoto
    Mitsudo, Kenji
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY MEDICINE AND PATHOLOGY, 2020, 32 (06) : 529 - 533
  • [43] One-stage bilateral implantation of a calcar-guided short-stem in total hip arthroplasty Minimally invasive modified anterolateral approach in supine position
    Kutzner, K. P.
    Donner, S.
    Schneider, M.
    Pfeil, J.
    Rehbein, P.
    OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE, 2017, 29 (02): : 180 - 192
  • [44] Impact of surgical approaches on stem position and hidden blood loss in total hip arthroplasty: minimally invasive vs. posterolateral
    Yuan, Gongwu
    Xiao, Yaoguang
    Li, Zhigang
    Chen, Zijian
    Liu, Ximing
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
  • [45] Electromyographic study of hip muscles involved in total hip arthroplasty: Surprising results using the direct anterior minimally invasive approach
    Bernard, Jules
    Razanabola, Fredson
    Beldame, Julien
    Van Driessche, Stephane
    Brunel, Helena
    Poirier, Thomas
    Matsoukis, Jean
    Billuart, Fabien
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2018, 104 (08) : 1137 - 1142
  • [46] Commentary: Minimally Invasive Parafascicular Surgery for Resection of Cerebral Cavernous Malformations Utilizing Image-Guided BrainPath System
    Maragkos, Georgios A.
    Thomas, Ajith J.
    OPERATIVE NEUROSURGERY, 2019, 17 (04) : E141 - E142
  • [47] New real-time MR image-guided surgical robotic system for minimally invasive precision surgery
    M. Hashizume
    T. Yasunaga
    K. Tanoue
    S. Ieiri
    K. Konishi
    K. Kishi
    H. Nakamoto
    D. Ikeda
    I. Sakuma
    M. Fujie
    T. Dohi
    International Journal of Computer Assisted Radiology and Surgery, 2008, 2 : 317 - 325
  • [48] A Minimally Invasive Multimodality Image-Guided (MIMIG) Molecular Imaging System for Peripheral Lung Cancer Intervention and Diagnosis
    He, Tiancheng
    Xue, Zhong
    Wong, Kelvin K.
    Valdivia y Alvarado, Miguel
    Zhang, Yong
    Xie, Weixin
    Wong, Stephen T. C.
    INFORMATION PROCESSING IN COMPUTER-ASSISTED INTERVENTIONS, 2010, 6135 : 102 - +
  • [49] New real-time MR image-guided surgical robotic system for minimally invasive precision surgery
    Hashizume, M.
    Yasunaga, T.
    Tanoue, K.
    Ieiri, S.
    Konishi, K.
    Kishi, K.
    Nakamoto, H.
    Ikeda, D.
    Sakuma, I.
    Fujie, M.
    Dohi, T.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2008, 2 (06) : 317 - 325