Image-guided navigation system for minimally invasive total hip arthroplasty (MITHA) using an improved position-sensing marker

被引:5
|
作者
Xie, Xianzhong [1 ]
Zhu, Mingzhu [1 ]
He, Bingwei [1 ]
Xu, Jie [2 ]
机构
[1] Fuzhou Univ, Sch Mech Engn, Fuzhou 350108, Fujian, Peoples R China
[2] Fujian Prov Hosp, Dept Orthoped Surg, Fuzhou 350013, Fujian, Peoples R China
基金
中国国家自然科学基金;
关键词
Surgery navigation; Minimally invasive total hip arthroplasty; Tracking; Point-based registration; Position-sensing marker; SURGICAL NAVIGATION; DYNAMIC NAVIGATION; POSE ESTIMATION; ACCURACY; TRACKING; REGISTRATION; PLACEMENT; TOOL;
D O I
10.1007/s11548-023-02861-x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
PurposeMinimally invasive total hip arthroplasty (MITHA) is a treatment for hip arthritis, and it causes less tissue trauma, blood loss, and recovery time. However, the limited incision makes it difficult for surgeons to perceive the instruments' location and orientation. Computer-assisted navigation systems can help improve the medical outcome of MITHA. Directly applying existing navigation systems for MITHA, however, suffers from problems of bulky fiducial marker, severe feature-loss, multiple instruments tracking confusion, and radiation exposure. To tackle these problems, we propose an image-guided navigation system for MITHA using a novel position-sensing marker.MethodsA position-sensing marker is proposed to serve as the fiducial marker with high-density and multi-fold ID tags. It results in less feature span and enables the use of ID for each feature, overcoming the problem of bulky fiducial markers and multiple instruments tracking confusion. And the marker can be recognized even when a large part of locating features is obscured. As for the elimination of intraoperative radiation exposure, we propose a point-based method to achieve patient-image registration based on anatomical landmarks.ResultsQuantitative experiments are conducted to evaluate the feasibility of our system. The accuracy of instrument positioning is achieved at 0.33 +/- 0.18 mm, and that of patient-image registration is achieved at 0.79 +/- 0.15 mm. And qualitative experiments are also performed, verifying that our system can be used in compact surgical spatial volume and can address severe feature-loss and tracking confusion problems. In addition, our system does not require any intraoperative medical scans.ConclusionExperimental results indicate that our proposed system can assist surgeons without larger space occupations, radiation exposure, and extra incision, showing its potential application value in MITHA.
引用
收藏
页码:2155 / 2166
页数:12
相关论文
共 50 条
  • [31] Total hip arthroplasty with the minimally invasive anterior approach using a specifically designed operating table
    Ho-man, Truong P.
    Nguyen, Van H.
    CHIRURGIA-ITALY, 2024, 37 (05): : 340 - 348
  • [32] Magnetic resonance and ultrasound image-guided navigation system using a needle manipulator
    Yamada, Atsushi
    Tokuda, Junichi
    Naka, Shigeyuki
    Murakami, Koichiro
    Tani, Tohru
    Morikawa, Shigehiro
    MEDICAL PHYSICS, 2020, 47 (03) : 850 - 858
  • [33] Model-Based Cone-Beam CT Reconstruction for Image-Guided Minimally Invasive Treatment of Hip Osteolysis
    Otake, Y.
    Stayman, J. W.
    Zbijewski, W.
    Murphy, R. J.
    Kutzer, M. D.
    Taylor, R. H.
    Siewerdsen, J. H.
    Armand, M.
    MEDICAL IMAGING 2013: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2013, 8671
  • [34] Two-Incision Minimally Invasive vs Standard Total Hip Arthroplasty: Comparison of Component Position and Hospital Costs
    Amman, Sean
    Cizik, Amy
    Leopold, Seth S.
    Manner, Paul A.
    JOURNAL OF ARTHROPLASTY, 2012, 27 (08): : 1569 - 1574
  • [35] Minimally invasive procedures - Advances in image-guided delivery of drug and cell therapies into the central nervous system
    Broaddus, WC
    Gillies, GT
    Kucharczyk, J
    NEUROIMAGING CLINICS OF NORTH AMERICA, 2001, 11 (04) : 727 - +
  • [36] Minimally Invasive Parafascicular Surgery for Resection of Cerebral Cavernous Malformations Utilizing Image-Guided BrainPath System
    Goren, Oded
    Griessenauer, Christoph J.
    Bohan, Christian O.
    Berry, Christopher M.
    Schirmer, Clemens M.
    OPERATIVE NEUROSURGERY, 2019, 17 (04) : 348 - 352
  • [37] Comparison of accuracy of cup position using portable navigation versus alignment guide in total hip arthroplasty in supine position
    Okamoto, Masanori
    Kawasaki, Masashi
    Okura, Toshiaki
    Ochiai, Satoshi
    Yokoi, Hiroyuki
    HIP INTERNATIONAL, 2021, 31 (04) : 492 - 499
  • [38] Effect of improved navigation performance on the accuracy of implant placement in total hip arthroplasty with a CT-based navigation system
    Ichiro Nakahara
    Takayuki Kyo
    Yasuo Kuroda
    Hidenobu Miki
    Journal of Artificial Organs, 2018, 21 : 340 - 347
  • [39] Effect of improved navigation performance on the accuracy of implant placement in total hip arthroplasty with a CT-based navigation system
    Nakahara, Ichiro
    Kyo, Takayuki
    Kuroda, Yasuo
    Miki, Hidenobu
    JOURNAL OF ARTIFICIAL ORGANS, 2018, 21 (03) : 340 - 347
  • [40] Early results and patient satisfaction after total hip arthroplasty using a minimally invasive anterolateral approach
    Walde, Tim Alexander
    Blattgerste, Dirk
    Sehmisch, Stefan
    Kuttler, Wolfgang
    Walde, Hans-Joachim
    Koester, Georg
    HIP INTERNATIONAL, 2009, 19 (04) : 367 - 371