System characterization and performance studies with MACACO III Compton camera

被引:8
|
作者
Barrientos, L. [1 ]
Borja-Lloret, M. [1 ]
Casana, J. V. [1 ]
Hueso-Gonzalez, F. [1 ]
Ros, A. [1 ]
Roser, J. [1 ]
Senra, C. [1 ]
Solaz, C. [1 ]
Viegas, R. [1 ]
Llosa, G. [1 ]
机构
[1] CSIC UV, Inst Fis Corpuscular IF, Valencia, Spain
关键词
Compton camera; Scintillator crystals; Silicon photomultipliers; PROTON THERAPY; RECONSTRUCTION; FEASIBILITY; TELESCOPE; BEAMS;
D O I
10.1016/j.radphyschem.2023.110922
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The IRIS group of IFIC-Valencia has developed a Compton camera prototype. The system detectors are made of Lanthanum (III) bromide scintillator crystals coupled to silicon photomultipliers. Two models of silicon photomultipliers arrays with different micro pixel pitch (25 and 50 mu m) have been chosen as possible candidates to improve the response of the new system. Characterization studies with a 22Na point-like source have indicated that the 25 mu m photodetector provided better performance in terms of energy resolution (5.2% FWHM at 511 keV) and angular resolution (6.9 degrees FWHM at 1275 keV), and more stability with temperature variations. In addition, MACACO III imaging capabilities have been assessed using a structure composed of thirty-seven 22Na point-like sources. Furthermore, in order to evaluate possible ways of improving the system performance, several studies have been carried out by means of simulations both in realistic and performance improved conditions. In this work, the system performance is evaluated for its future application in different areas.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] A Double Photomultiplier Compton Camera And Its Readout System For Mice Imaging
    Fontana, Cristiano Lino
    Atroshchenko, Kostiantyn
    Baldazzi, Giuseppe
    Bello, Michele
    Uzunov, Nikolay
    Di Domenico, Giovanni
    APPLICATION OF ACCELERATORS IN RESEARCH AND INDUSTRY, 2013, 1525 : 332 - 336
  • [42] Compton camera study for high efficiency SPECT and benchmark with Anger system
    Fontana, M.
    Dauvergne, D.
    Letang, J. M.
    Ley, J-L
    Testa, E.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (23): : 8794 - 8812
  • [43] Development of a multi-channel signal optimizer for a Compton camera system
    Lee, J. H.
    Lee, C. S.
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2008, 52 (04) : 999 - 1003
  • [44] Development of Imaging System of Array Compton Camera for Nuclear Decommissioning Scenarios
    Liu Xin
    Feng Peng
    Yao Zhiyang
    Zhang Song
    Qian Yikun
    Liu Yixin
    Wu Jian
    Yuan Yonggang
    Qu Jinhui
    Bai Yanjun
    ACTA OPTICA SINICA, 2022, 42 (24)
  • [45] A DATA-ACQUISITION SYSTEM FOR A RING COMPTON-SCATTER CAMERA
    JORDANOV, VT
    PETRICK, N
    MARTIN, JB
    WEHE, DK
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (01) : 92 - 96
  • [46] Monitoring Ion Beam Therapy With a Compton Camera: Simulation Studies of the Clinical Feasibility
    Fontana, M.
    Ley, J. -L.
    Dauvergne, D.
    Freud, N.
    Krimmer, J.
    Letang, J. M.
    Maxim, V.
    Richard, M. -H.
    Rinaldi, I.
    Testa, E.
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2020, 4 (02) : 218 - 232
  • [47] Study of the polarimetric performance of a Si/CdTe semiconductor Compton camera for the Hitomi satellite
    Katsuta, Junichiro
    Edahiro, Ikumi
    Watanabe, Shin
    Odaka, Hirokazu
    Uchida, Yusuke
    Uchida, Nagomi
    Mizuno, Tsunefumi
    Fukazawa, Yasushi
    Hayashi, Katsuhiro
    Habata, Sho
    Ichinohe, Yuto
    Kitaguchi, Takao
    Ohno, Masanori
    Ohta, Masayuki
    Takahashi, Hiromitsu
    Takahashi, Tadayuki
    Takeda, Shin'ichiro
    Tajima, Hiroyasu
    Yuasa, Takayuki
    Itou, Masayoshi
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 840 : 51 - 58
  • [48] Performance evaluation of Compton based camera for high energy gamma ray imaging
    Han, Li
    Clinthorne, Neal H.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2561 - 2565
  • [49] Performance evaluation of a table-top Compton camera for various detector parameters
    Lee, Se Hyung
    Seo, Hee
    An, So Hyun
    Lee, Jae Sung
    Kim, Chan Hyeong
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 591 (01): : 88 - 91
  • [50] 99mTc imaging performance of the C-SPRINT compton camera
    LeBlanc, JW
    Bai, X
    Clinthorne, NH
    Hua, C
    Meier, D
    Rogers, WL
    Wehe, DK
    Weilhammer, P
    Wilderman, SJ
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 545 - 552