Mechanical properties of an innovative steel-concrete joint for high-speed railway long-span hybrid girder cable-stayed bridges

被引:4
|
作者
Shi, Zhou [1 ,2 ]
Gu, Jiachang [1 ]
Li, Yingming [1 ]
Zhang, Ying [1 ]
Zhao, Xupo [1 ]
机构
[1] Southwest Jiaotong Univ, Sch Civil Engn, Dept Bridge Engn, Sect 111 Northbound 1,Second Ring Rd, Chengdu 610031, Sichuan, Peoples R China
[2] Southwest Jiaotong Univ, Natl Key Lab Bridge Intelligent & Green Construct, Chengdu 611756, Sichuan, Peoples R China
关键词
High-speed railway; Hybrid cable-stayed bridge; Steel -concrete joint; Model test; Force transfer mechanism; Bearing plate; Parametric analysis;
D O I
10.1016/j.engstruct.2023.117170
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study investigates the mechanical properties of an innovative steel-concrete joint (SCJ) in a four-line long-span high-speed railway hybrid girder cable-stayed bridge with a main span of 672 m. Tests were conducted on a partial 3:8 scale model, supported by nonlinear finite element analysis (FEA), and the results of both were used to derive and validate mathematical formulae for bearing plate force transfer. The results revealed an uneven transverse distribution of stress in the SCJ, with a larger stress observed in the edge box. The non-uniformity coefficient lambda i is defined as the ratio of the absolute maximum stress to the transverse cross-sectional average at a given location, and lambda i,max of steel and concrete in the SCJ were 1.59 and 1.68, respectively. Drastic stress changes appeared in the bearing plate in the longitudinal direction. The maximum measured slip was relatively small, indicating that the steel and concrete in the SCJ functioned cooperatively. Concrete cracks observed in physical tests were mainly distributed in the edge box of the steel and concrete segments, revealing the superior force performance of the SCJ compared to the steel and concrete segments. The deformations of the SCJ changed elastically with an increasing load and satisfied Chinese standards. The bearing plate transferred approximately 59.92% of the axial force and dominated the force transfer. Formulae for the force transfer of the bearing plate were derived based on the stress characteristics of the innovative SCJ, revealing that, rather than its thickness, the bearing plate mainly relied on welds connecting the top and bottom plates and ribs to transfer force. Parameter analysis of the weld sizes of the bearing plate based on the derived formulae and FEA indicated that a reasonable thickness of the bearing plate is 38-60 mm, based on the matched weld sizes. The SCJ structure, the formulae for bearing plate force transfer, and the optimal bearing plate thickness can serve as valuable references during the initial design phase of SCJs.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Influencing factors of impact coefficient for long-span railway cable-stayed bridges
    Li, Yong-Le
    Bao, Yu-Long
    Dong, Shi-Fu
    Zeng, Yong-Ping
    Xiang, Huo-Yue
    Zhendong yu Chongji/Journal of Vibration and Shock, 2015, 34 (19): : 138 - 143
  • [32] Study on The Mechanical and Economic Performance of Super Long-Span Cable-Stayed Bridges with UHPC-Girder
    Ai, Zubin
    Liu, Hangjun
    Zhang, Jiaguo
    Zhang, Chao
    Wang, Cong
    Jiang, Zuqian
    Xiao, Rucheng
    KSCE JOURNAL OF CIVIL ENGINEERING, 2023, 27 (11) : 4744 - 4761
  • [33] Study on The Mechanical and Economic Performance of Super Long-Span Cable-Stayed Bridges with UHPC-Girder
    Zubin Ai
    Hangjun Liu
    Jiaguo Zhang
    Chao Zhang
    Cong Wang
    Zuqian Jiang
    Rucheng Xiao
    KSCE Journal of Civil Engineering, 2023, 27 : 4744 - 4761
  • [34] Analysis of Parameters' Sensitiveness of Long-span Hybrid Girder Cable-stayed Bridge
    Li, Zhongsan
    Lei, Junqing
    Yan, Donghuang
    NOVEL AND NON-CONVENTIONAL MATERIALS AND TECHNOLOGIES FOR SUSTAINABILITY, 2012, 517 : 817 - +
  • [35] Experimental Study of the Steel-Concrete Connection in Hybrid Cable-Stayed Bridges
    He, Jun
    Liu, Yuqing
    Pei, Bingzhi
    JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES, 2014, 28 (03) : 559 - 570
  • [36] Damping properties of FRP cables for long-span cable-stayed bridges
    Yaqiang Yang
    Xin Wang
    Zhishen Wu
    Changhai Peng
    Materials and Structures, 2016, 49 : 2701 - 2713
  • [37] Research on Key Design Techniques of Long-Span Steel-Truss-Stiffened PC Box Girder Cable-Stayed Bridge Accommodating High-Speed Railway
    Wen, Qiang
    Lu, Hao
    Kang, Wei
    Chen, Ying-Tao
    Bridge Construction, 2022, 52 (05) : 107 - 113
  • [38] Damping properties of FRP cables for long-span cable-stayed bridges
    Yang, Yaqiang
    Wang, Xin
    Wu, Zhishen
    Peng, Changhai
    MATERIALS AND STRUCTURES, 2016, 49 (07) : 2701 - 2713
  • [39] Mechanical behavior of a novel steel-concrete joint in hybrid girder cable-stayed bridge (vol 57, 105239, 2023)
    Zhao, Lanting
    Pu, Guangning
    Yuan, Yangguang
    Guo, Qi
    Yu, Yongliang
    STRUCTURES, 2024, 62
  • [40] Damping Analysis of Viscous Damper on Coupling System for High-Speed Trains and Long-Span Cable-Stayed Bridges
    Guo W.
    Duan B.
    Zhang T.
    Zhongguo Tiedao Kexue/China Railway Science, 2022, 43 (04): : 9 - 17