Quantification of Thin Walls and Capsules Using X-Ray Computed Tomography

被引:0
|
作者
Patterson, Brian M. [1 ]
Young, Steven G. [1 ]
Morrow, Tana [1 ]
Day, Thomas [1 ]
Schmidt, Derek [1 ]
Cordes, Nikolaus L. [1 ]
机构
[1] Los Alamos Natl Lab, Engn Mat Grp, Los Alamos, NM 87545 USA
关键词
X-ray tomography; opacity target; double shell; metrology; FABRICATION; IMAGE;
D O I
10.1080/15361055.2023.2185030
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
X-ray computed tomography (CT) is widely used in material science to understand the inner morphology of a specimen. Often, it is used to qualitatively understand the distribution of salient features such as cracks, voids, or particles. There are many challenges in using X-ray CT in a quantitative manner. These include a coarser resolution for comparable fields of view when compared to other imaging techniques (i.e., electron or optical microscopy), imaging artifacts (i.e., beam hardening and phase contrast), and the plethora of imaging and processing parameters that are chosen by the instrument/software user that can significantly affect the resultant measures. These limitations must be considered and quantified to acquire accurate and precise measurements. X-ray CT is powerful in that it can measure, in three dimensions, salient features that are subsurface and cannot be imaged with other direct line-of-sight imaging techniques. In this work, we discuss the use of X-ray CT to measure the thickness variations of thin walls of opacity capsules as well as the measurement of double-shell targets to understand the concentricity of the capsules within each other. Morphological measurements needed for target characterization require very high accuracy and precision. This paper will describe the application for the first time of a variety of measurements and will explore their robustness and pros and cons to identify areas of research to improve their accuracy and precision.
引用
收藏
页码:895 / 906
页数:12
相关论文
共 50 条
  • [41] Quasimonochromatic x-ray computed tomography by the balanced filter method using a conventional x-ray source
    Saito, M
    MEDICAL PHYSICS, 2004, 31 (12) : 3436 - 3443
  • [42] DEMONSTRATION OF PHASE-CONTRAST X-RAY COMPUTED-TOMOGRAPHY USING AN X-RAY INTERFEROMETER
    MOMOSE, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 352 (03): : 622 - 628
  • [43] Characterizing soil macroporosity by X-ray microfocus computed tomography and quantification of the coring damages
    Gallier, J.
    Hubert, F.
    Robinet, J-C.
    Sardini, P.
    Caner, L.
    ICEM 14: 14TH INTERNATIONAL CONFERENCE ON EXPERIMENTAL MECHANICS, VOL 6, 2010, 6
  • [44] X-ray computed tomography for medical imaging
    Hiriyannaiah, HP
    IEEE SIGNAL PROCESSING MAGAZINE, 1997, 14 (02) : 42 - 59
  • [45] Contemporary developments in computed X-ray tomography
    Seibert, JA
    RADIOLOGY, 1998, 209P : 207 - 208
  • [46] Microscopic x-ray luminescence computed tomography
    Zhang, Wei
    Zhu, Dianwen
    Zhang, Kun
    Li, Changqing
    MULTIMODAL BIOMEDICAL IMAGING X, 2015, 9316
  • [47] X-ray computed tomography in life sciences
    Shelley D. Rawson
    Jekaterina Maksimcuka
    Philip J. Withers
    Sarah H. Cartmell
    BMC Biology, 18
  • [48] STATISTICAL ASPECTS OF COMPUTED X-RAY TOMOGRAPHY
    CHESLER, DA
    PELC, NJ
    RIEDERER, SJ
    PHYSICS IN MEDICINE AND BIOLOGY, 1977, 22 (01): : 130 - 131
  • [49] X-ray computed tomography of ultralightweight metals
    Winter, JM
    Green, RE
    Waters, AM
    Green, WH
    RESEARCH IN NONDESTRUCTIVE EVALUATION, 1999, 11 (04) : 199 - 211
  • [50] X-Ray Luminescence Computed Tomography Via Selective X-Ray Excitation
    Pratx, G.
    Carpenter, C.
    Sun, C.
    Xing, L.
    MEDICAL PHYSICS, 2010, 37 (06)