Energy and Exergy Analysis of an Automobile Hybrid Ejector Refrigeration System Utilizing Its Exhaust Waste Heat

被引:0
|
作者
Abbady, Karim [1 ]
Al-Mutawa, Nawaf [1 ]
Almutairi, Abdulrahman [2 ]
机构
[1] Kuwait Univ, Coll Engn & Petr, Dept Mech Engn, POB 5969, Safat 13060, Kuwait
[2] Coll Technol Studies, Publ Author Appl Educ & Training, Dept Mech Power & Refrigerat, POB 23167, Safat 13092, Kuwait
关键词
cars air conditioning; refrigeration; environment-friendly refrigerants; thermodynamics; CFD; exergy; VAPOR COMPRESSION; CYCLE; PERFORMANCE; DESIGN;
D O I
10.1115/1.4062557
中图分类号
O414.1 [热力学];
学科分类号
摘要
A major current focus of refrigeration and air-conditioning research is energy usage and environmental impact (e.g., the influence of refrigerants and air-conditioning systems on ozone layer depletion and global warming). The ejector-based refrigeration system is a technology that, it is hoped, can save power while using environment-friendly refrigerants to reduce any adverse effects on nature. The reduction of compressor dependency is the first and essential aim of this study; the second is to demonstrate the replacement of R134a with the new refrigerant R1234yf in motor vehicle air-conditioning systems, establishing the benefits of employing R1234yf in conjunction with a hybrid air-conditioning system. In such a system, the engine's exhaust gases are used to operate the ejector. A numerical model has been developed which estimates the ejector entrainment ratio at a specified spindle and primary nozzle exit position. A theoretical model using energy and exergy analysis illustrates the impact of hybrid systems on performance under different operating conditions (i.e., engine exhaust, ambient air, and evaporator temperatures). At a specified exhaust temperature, a detailed comparison has been conducted between a current air-conditioning system with R134a and the hybrid system with R1234yf. It was found that the R1234yf hybrid system reduced compressor energy consumption by 44.43% and operating exhaust heat levels by 12.79%. The coefficient of performance increased by 41.42%, while the exergetic efficiency reduced from 37.14% to 13.85%. Cooling capacity dropped by 12.73%. The hybrid air-conditioning system based on R1234yf demonstrated tremendous potential for improving vehicle air-conditioning system efficiency.
引用
收藏
页数:16
相关论文
共 50 条