Energy and Exergy Analysis Study of Heat Exchanger in a Refrigeration System with Different Lengths of Capillary Tube

被引:6
|
作者
Salem, Thamer Khalif [1 ]
Farhan, Saad Sami [1 ]
Farhan, Israa Sami [1 ]
机构
[1] Tikrit Univ, Engn Fac, Mech Dept, Tikrit, Iraq
关键词
Capillary tube length; Suction line; Exergy; Heat exchanger; R134a; NUMERICAL-SIMULATION; PART II; FLOW;
D O I
10.5541/ijot.758705
中图分类号
O414.1 [热力学];
学科分类号
摘要
An experimental study was conducted to demonstrate the effect of a capillary tube length on the refrigeration system performance by adding heat exchanger. The heat exchanger was designed by laterally welding 70cm of capillary tube with the suction line. Different lengths of the capillary tubes, i.e. 160, 175, and 190cm, were studied; besides different refrigerant flow rates and condenser air fan velocities for both cases of adiabatic and nonadiabatic capillary tube. The experimental results showed an increase in the system performance by 17.96% with a decrease in the nonadiabatic capillary tube length from 190 to 160 cm at mass flow rate of 17.3 kg/hr and air velocity of 3 m/s. In addition, the increase in the air-speed has led to a COP increment by 17.47% at mass flow rate of 18.9 kg/hr and capillary tube length of 190 cm. Finally, at the capillary tube length of 190cm and refrigerant mass flow rate of 2.4g/s, the maximum enhancement of the refrigeration system performance and exergy efficiency by 6.7% and 35%, respectively, was achieved for air speed of 1m/s and 3 m/s, compared to the reference case of the adiabatic capillary tubes.
引用
收藏
页码:260 / 266
页数:7
相关论文
共 50 条
  • [1] ENERGY AND EXERGY ANALYSIS OF A REFRIGERATION SYSTEM WITH SHELL AND TUBE HEAT EXCHANGER USING R404A
    Kabul, Ahmet
    Kizilkan, Onder
    Yakut, Ali Kemal
    ISI BILIMI VE TEKNIGI DERGISI-JOURNAL OF THERMAL SCIENCE AND TECHNOLOGY, 2010, 30 (02) : 85 - 93
  • [2] The heat exchangers tubes mineral type effect on the refrigeration system performance using different lengths of the capillary tube
    Salem, Thamer Khalif
    Farhan, Saad Sami
    Doury, Raaid Rashad Jassem Al
    Farhan, Israa Sami
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2021, 235 (22) : 6541 - 6548
  • [3] Energy and exergy analysis of a double effect absorption refrigeration system based on different heat sources
    Kaynakli, Omer
    Saka, Kenan
    Kaynakli, Faruk
    ENERGY CONVERSION AND MANAGEMENT, 2015, 106 : 21 - 30
  • [4] ENERGY AND EXERGY ANALYSIS OF DOUBLE PIPE MINI-TUBE HEAT EXCHANGER
    Gelis, K.
    Ozbek, K.
    Bolu, T. Mermer
    JOURNAL OF ENHANCED HEAT TRANSFER, 2024, 31 (07) : 45 - 66
  • [5] Numerical Study of Heat Transfer and Exergy Analysis of Shell and Double Tube Heat Exchanger
    Abdulrahman, Ruslan S.
    Ibrahim, Farah A.
    Faisel, Safaa H.
    INTERNATIONAL JOURNAL OF HEAT AND TECHNOLOGY, 2020, 38 (04) : 925 - 932
  • [6] Impact of the Capillary Tube Length on the Refrigeration Cycle Exergy
    Al-Doori, Ghassan F.
    Khalaf, Samer M.
    Nazzal, Ibrahim T.
    International Journal of Heat and Technology, 2024, 42 (05) : 1769 - 1776
  • [7] Energy and exergy analysis of an ejector refrigeration system
    Untea, George Adrian
    Dobrovicescu, Alexandru
    Grosu, Lavinia
    Mladin, Emilia Cerna
    UPB Scientific Bulletin, Series D: Mechanical Engineering, 2013, 75 (04): : 111 - 126
  • [8] Exergy analysis of a shell and tube heat exchanger using DETHE software
    Zueco, Joaquin
    Ayala-Minano, Sergio
    INTERNATIONAL JOURNAL OF EXERGY, 2020, 33 (02) : 198 - 213
  • [9] Energy and exergy analysis of single-effect absorption refrigeration system with different refrigerants
    Li J.
    Wang G.
    Xiong Y.
    Xu Q.
    Huagong Jinzhan/Chemical Industry and Engineering Progress, 2023, 42 : 104 - 112
  • [10] Exergy efficiency analysis of a shell and tube heat exchanger condenser based on its different design parameters
    Fakhrolmobasheri, Navid
    Rostami, Mohsen
    HEAT TRANSFER-ASIAN RESEARCH, 2019, 48 (07): : 3295 - 3311