Energy and Exergy Analysis of an Automobile Hybrid Ejector Refrigeration System Utilizing Its Exhaust Waste Heat

被引:0
|
作者
Abbady, Karim [1 ]
Al-Mutawa, Nawaf [1 ]
Almutairi, Abdulrahman [2 ]
机构
[1] Kuwait Univ, Coll Engn & Petr, Dept Mech Engn, POB 5969, Safat 13060, Kuwait
[2] Coll Technol Studies, Publ Author Appl Educ & Training, Dept Mech Power & Refrigerat, POB 23167, Safat 13092, Kuwait
关键词
cars air conditioning; refrigeration; environment-friendly refrigerants; thermodynamics; CFD; exergy; VAPOR COMPRESSION; CYCLE; PERFORMANCE; DESIGN;
D O I
10.1115/1.4062557
中图分类号
O414.1 [热力学];
学科分类号
摘要
A major current focus of refrigeration and air-conditioning research is energy usage and environmental impact (e.g., the influence of refrigerants and air-conditioning systems on ozone layer depletion and global warming). The ejector-based refrigeration system is a technology that, it is hoped, can save power while using environment-friendly refrigerants to reduce any adverse effects on nature. The reduction of compressor dependency is the first and essential aim of this study; the second is to demonstrate the replacement of R134a with the new refrigerant R1234yf in motor vehicle air-conditioning systems, establishing the benefits of employing R1234yf in conjunction with a hybrid air-conditioning system. In such a system, the engine's exhaust gases are used to operate the ejector. A numerical model has been developed which estimates the ejector entrainment ratio at a specified spindle and primary nozzle exit position. A theoretical model using energy and exergy analysis illustrates the impact of hybrid systems on performance under different operating conditions (i.e., engine exhaust, ambient air, and evaporator temperatures). At a specified exhaust temperature, a detailed comparison has been conducted between a current air-conditioning system with R134a and the hybrid system with R1234yf. It was found that the R1234yf hybrid system reduced compressor energy consumption by 44.43% and operating exhaust heat levels by 12.79%. The coefficient of performance increased by 41.42%, while the exergetic efficiency reduced from 37.14% to 13.85%. Cooling capacity dropped by 12.73%. The hybrid air-conditioning system based on R1234yf demonstrated tremendous potential for improving vehicle air-conditioning system efficiency.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Exergy Analysis of Methane Steam Reformer Utilizing Steelmaking Waste Heat
    Maruoka, Nobuhiro
    Purwanto, Hadi
    Akiyama, Tomohiro
    [J]. ISIJ INTERNATIONAL, 2010, 50 (09) : 1311 - 1318
  • [42] Energy and exergy analysis of bus refrigeration system using two-phase ejector with natural refrigerant R744
    Kutlu, Cagri
    Unal, Saban
    Erdinc, M. Tahir
    Cihan, Ertugrul
    [J]. INTERNATIONAL JOURNAL OF EXERGY, 2017, 22 (04) : 331 - 351
  • [43] Comparison of an absorption-compression hybrid refrigeration system and the conventional absorption refrigeration system: Exergy analysis
    Pacheco-Cedeno, J. S.
    Rodriguez-Munoz, J. L.
    Ramirez-Minguela, J. J.
    Perez-Garcia, V.
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 155 : 81 - 92
  • [44] Energy and Exergy Analysis of Different Exhaust Waste Heat Recovery Systems for Natural Gas Engine Based on ORC
    Valencia, Guillermo
    Fontalvo, Armando
    Cardenas, Yulineth
    Duarte, Jorge
    Isaza, Cesar
    [J]. ENERGIES, 2019, 12 (12)
  • [45] Energy and exergy analysis of a novel ejector-absorption combined refrigeration cycle using natural refrigerants
    Verma, Abhishek
    Kaushik, S. C.
    Tyagi, S. K.
    [J]. INTERNATIONAL JOURNAL OF EXERGY, 2022, 39 (02) : 142 - 159
  • [46] Energy and exergy analysis of R22 and its alternatives in a vapour compression refrigeration system
    Menlik, Tayfun
    Demircioglu, Ahmet
    Ozkaya, Musa Galip
    [J]. INTERNATIONAL JOURNAL OF EXERGY, 2013, 12 (01) : 11 - 30
  • [47] Advanced Exergy and Exergoeconomic Analysis of Cascade Absorption Refrigeration System Driven by Low-Grade Waste Heat
    Yu, Mengxiao
    Cui, Peizhe
    Wang, Yinglong
    Liu, Zhiqiang
    Zhu, Zhaoyou
    Yang, Sheng
    [J]. ACS SUSTAINABLE CHEMISTRY & ENGINEERING, 2019, 7 (19) : 16843 - 16857
  • [48] ENERGY AND EXERGY ANALYSIS OF A REFRIGERATION SYSTEM WITH SHELL AND TUBE HEAT EXCHANGER USING R404A
    Kabul, Ahmet
    Kizilkan, Onder
    Yakut, Ali Kemal
    [J]. ISI BILIMI VE TEKNIGI DERGISI-JOURNAL OF THERMAL SCIENCE AND TECHNOLOGY, 2010, 30 (02) : 85 - 93
  • [49] Thermal, Energy and Exergy Analysis of Thermoelectric Generator System for Waste Heat Recovery Applications
    Viorel, Ionescu
    [J]. JOURNAL OF ECOLOGICAL ENGINEERING, 2024, 25 (07): : 201 - 211
  • [50] Advanced exergy analysis of NH3/CO2 cascade refrigeration system with ejector
    Chi, Weikai
    Yang, Qichao
    Chen, Xiaonan
    Li, Liansheng
    Liu, Guangbin
    Zhao, Yuanyang
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 145 : 185 - 195