Organ dose in CT: Comparison between measurements and computational methods

被引:2
|
作者
Pace, Martina [1 ]
Bonanno, Elisa [1 ]
Borzi, Giuseppina Rita [1 ]
Cavalli, Nina [1 ]
D'Anna, Alessia [2 ]
Gueli, Anna Maria [2 ]
Stella, Giuseppe [2 ]
Zirone, Lucia [1 ,2 ]
Marino, Camelo [1 ]
机构
[1] Human Ist Clin Catanese, Med Phys Dept, Misterbianco, CT, Italy
[2] Univ Catania, Dept Phys & Astron E Majorana, Catania, Italy
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2023年 / 112卷
关键词
DoseWatch TM; EBT-3; XR-QA2; Patient dosimetry; Diagnostic radiology; RADIOCHROMIC FILMS; DOSIMETRY; PROTOCOL; QUALITY; SCANNER; PHANTOM;
D O I
10.1016/j.ejmp.2023.102627
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This study aims to compare two methods for the organ dose evaluation in computed tomography (CT) in the head- and thorax regions: an experimental method, using radiochromic films, and a computational one, using a commercial software.Methods: Gafchromic & REG; XR-QA2 and EBT-3 were characterized in terms of energetic, angular, and irradiation configurations dependence. Two free-in-air irradiation calibration configurations were employed using a CT scanner: with the sensitive surface of the film orthogonal (OC) and parallel (PC) to the beam axis. Different dose-response curves were obtained by varying the irradiation configurations and the beam quality (BQ). Subsequently, films were irradiated within an anthropomorphic phantom using CT-thorax and -head protocols, and the organ dose values obtained were compared with those provided by the commercial software.Results: At different configurations, an unchanged dose response was achieved with EBT-3, while a dose response of 15% was obtained with XR-QA2. By varying BQ, XR-QA2 showed a different response below 10%, while EBT-3 showed a variation below 5% for dose values >20 mGy. For films irradiation angle equal to 90 degrees, the normalized to 0 degrees relative response was 41% for the XR-QA2 model and 83% for the EBT-3 one. Organ dose values obtained with EBT-3 for both configurations and with XR-QA2 for OC were in agreement with the DW values, showing percentage discrepancies of less than 25%. Conclusions: The obtained results showed the potential of EBT-3 in CT patient dosimetry since the lower angular dependence, compared to XR-QA2, compensates for low sensitivity in the diagnostic dose range.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Comparison of computational scattering methods
    Wriedt, T
    Comberg, U
    JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 1998, 60 (03): : 411 - 423
  • [42] Visualization and comparison of CT dose distribution between axial and helical acquisitions
    Yang, Kai
    Li, Xinhua
    Yu, Lifeng
    Li, Baojun
    Marschall, Theodore A.
    Liu, Bob
    MEDICAL PHYSICS, 2023, 50 (08) : 4797 - 4808
  • [43] Current and Future Measurements of CT Dose
    Cody, D.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [44] A comparison of computational methods for high-dimensional hierarchical nonlinear models for repeated measurements
    Segawa, E
    duToit, SHC
    Bock, RD
    AMERICAN STATISTICAL ASSOCIATION - 1996 PROCEEDINGS OF THE STATISTICAL COMPUTING SECTION, 1996, : 130 - 135
  • [45] Comparison between standard dose and 50%-reduced dose abdominal CT: Effect on image quality
    Prasad, SR
    Blake, MA
    Rhea, JT
    Simeone, JF
    Sahani, DV
    Saini, S
    RADIOLOGY, 2001, 221 : 550 - 550
  • [46] Adult Oncology CT Patient Organ Dose and Effective Dose Estimates
    Gao, Y.
    Quinn, B.
    Mahmood, J.
    Xu, X.
    Dauer, L.
    MEDICAL PHYSICS, 2018, 45 (06) : E599 - E599
  • [47] Evaluating Effective Dose: A Comparison of Methods Based on Organ Dose Calculations versus Dose-Length Product and Monte Carlo Simulation
    Abuelhia, Elfatih
    Tajaldeen, Abdulrahman
    Alghamdi, Ali
    Mabrouk, Osama
    Aluraik, Wejdan
    Msmar, Amir
    Elsadig, Muawia
    Osman, Entisar
    Al-Othman, Abdullah
    Alghamdi, Salem
    Albadri, Mesbah
    Aljondi, Rowa
    APPLIED SCIENCES-BASEL, 2022, 12 (13):
  • [48] Temporal Bone Measurements; A Comparison Between Rendered Spiral CT and Surgery
    Hashemi, Jahanbakhsh
    Rajati, Mohsen
    Rezayani, Lida
    Bahadori, Aria
    IRANIAN JOURNAL OF RADIOLOGY, 2014, 11 (03) : 1 - 6
  • [49] Dose measurements for dental cone-beam CT: a comparison with MSCT and panoramic imaging
    Deman, P.
    Atwal, P.
    Duzenli, C.
    Thakur, Y.
    Ford, N. L.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (12): : 3201 - 3222
  • [50] Monte Carlo Evaluation of CT-Scanner Scatter Dose to Operator and Comparison with Measurements
    Jans, H. S.
    Long, B.
    Robinson, D.
    MEDICAL PHYSICS, 2011, 38 (06)