Organ dose in CT: Comparison between measurements and computational methods

被引:2
|
作者
Pace, Martina [1 ]
Bonanno, Elisa [1 ]
Borzi, Giuseppina Rita [1 ]
Cavalli, Nina [1 ]
D'Anna, Alessia [2 ]
Gueli, Anna Maria [2 ]
Stella, Giuseppe [2 ]
Zirone, Lucia [1 ,2 ]
Marino, Camelo [1 ]
机构
[1] Human Ist Clin Catanese, Med Phys Dept, Misterbianco, CT, Italy
[2] Univ Catania, Dept Phys & Astron E Majorana, Catania, Italy
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2023年 / 112卷
关键词
DoseWatch TM; EBT-3; XR-QA2; Patient dosimetry; Diagnostic radiology; RADIOCHROMIC FILMS; DOSIMETRY; PROTOCOL; QUALITY; SCANNER; PHANTOM;
D O I
10.1016/j.ejmp.2023.102627
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This study aims to compare two methods for the organ dose evaluation in computed tomography (CT) in the head- and thorax regions: an experimental method, using radiochromic films, and a computational one, using a commercial software.Methods: Gafchromic & REG; XR-QA2 and EBT-3 were characterized in terms of energetic, angular, and irradiation configurations dependence. Two free-in-air irradiation calibration configurations were employed using a CT scanner: with the sensitive surface of the film orthogonal (OC) and parallel (PC) to the beam axis. Different dose-response curves were obtained by varying the irradiation configurations and the beam quality (BQ). Subsequently, films were irradiated within an anthropomorphic phantom using CT-thorax and -head protocols, and the organ dose values obtained were compared with those provided by the commercial software.Results: At different configurations, an unchanged dose response was achieved with EBT-3, while a dose response of 15% was obtained with XR-QA2. By varying BQ, XR-QA2 showed a different response below 10%, while EBT-3 showed a variation below 5% for dose values >20 mGy. For films irradiation angle equal to 90 degrees, the normalized to 0 degrees relative response was 41% for the XR-QA2 model and 83% for the EBT-3 one. Organ dose values obtained with EBT-3 for both configurations and with XR-QA2 for OC were in agreement with the DW values, showing percentage discrepancies of less than 25%. Conclusions: The obtained results showed the potential of EBT-3 in CT patient dosimetry since the lower angular dependence, compared to XR-QA2, compensates for low sensitivity in the diagnostic dose range.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] An overview of acquisition parameters, dose measurements and organ doses in abdominal CT scans in Brazil
    Campelo, D. A. M.
    Asfora, V. K.
    Barros, V. S. M.
    Medeiros, R. B.
    Khoury, H. J.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2020, 40 (04) : 1111 - 1122
  • [22] Relationship between specific organ doses and volumetric CT dose indices in multidetector CT studies
    Matsubara, Kosuke
    Koshida, Kichiro
    Noto, Kimiya
    Shimono, Tetsunori
    Yamamoto, Tomoyuki
    Matsui, Osamu
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2011, 55 (05) : 493 - 497
  • [23] Comparison of two CT-based organ volume estimation methods for mass correction of MIRD beta absorbed dose.
    Erwin, WD
    Groch, MW
    JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (05) : 198P - 199P
  • [24] A database of 40 patient-based computational models for benchmarking organ dose estimates in CT
    Samei, Ehsan
    Ria, Francesco
    Tian, Xiaoyu
    Segars, Paul W.
    MEDICAL PHYSICS, 2020, 47 (12) : 6562 - 6566
  • [25] Comparison of experimental and computational methods for discharge measurements from tidal wetlands
    Harding, Samuel F.
    Coleman, Andre M.
    Roegner, G. Curtis
    RIVER RESEARCH AND APPLICATIONS, 2020, 36 (09) : 1954 - 1961
  • [26] PAEDIATRIC CT EXPOSURES: COMPARISON BETWEEN CTDIVOL AND SSDE METHODS USING MEASUREMENTS AND MONTE CARLO SIMULATIONS
    Figueira, C.
    Di Maria, S.
    Baptista, M.
    Mendes, M.
    Madeira, P.
    Vaz, P.
    RADIATION PROTECTION DOSIMETRY, 2015, 165 (1-4) : 210 - 215
  • [27] Comparison of dose measurements in CT using a photodiode and a small ion chamber
    Paschoal, C. M. M.
    Ferreira, F. C. L.
    Souza, D. N.
    Santos, L. A. P.
    RADIATION MEASUREMENTS, 2016, 91 : 50 - 53
  • [28] Organ Dose, Effective Dose, and Dose Conversion Coefficients in Adult CT: Comparison of Mathematical, XCAT, and ICRP Reference Phantoms
    Zhang, Y.
    Li, X.
    Segars, W.
    Samei, E.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [29] Determination of dose from CT examinations: Estimating organ dose using Monte Carlo-based methods
    McNitt-Gray, M.
    MEDICAL PHYSICS, 2007, 34 (06) : 2538 - 2539
  • [30] COMPUTATIONAL METHODS FOR FERROELECTRIC MEASUREMENTS
    JINGDER, L
    FERROELECTRICS, 1981, 38 (1-4) : 915 - 918