Evaluating the sensitivity, stability, and cross-reactivity of commercial fentanyl immunoassay test strips

被引:4
|
作者
Rodriguez-Cruz, Sandra E. [1 ,2 ]
机构
[1] Drug Enforcement Adm, Special Testing & Res Lab, Dulles, VA USA
[2] Drug Enforcement Adm, Special Testing & Res Lab, 22624 Dulles Summit Ct, Dulles, VA 20166 USA
关键词
fentanyl; fentanyl test strips; fentanyl-related substance; harm reduction; lateral-flow immunoassay; opioid epidemic; seized drugs;
D O I
10.1111/1556-4029.15332
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
Illicit fentanyl has flooded the United States' drug market, increasing the risk of overdose and poisonings throughout the general population and accidental exposure among law enforcement officers confiscating the increasing number of seizures. Fentanyl test strips (FTS) are used to obtain presumptive information about the presence of fentanyl in a suspected sample. However, their adoption by law enforcement personnel and seized-drug analysts has been limited because most products are advertised for urine testing, not for assays using water solutions. This study presents an evaluation of four commercial FTS: Rapid Response from BTNX, Inc.; T-Dip Fentanyl (FTY) Urine Dip Cards obtained from ; Premier BioDip FYL10 from Premier Biotech Inc.; and MobileDetect Fentanyl strips from DetectaChem, Inc. Performance characteristics curves were used to compare the products' sensitivity, showing that all can reliably detect fentanyl in aqueous solutions at concentrations below 1 & mu;g/mL, with some of the tests able to reliably detect the drug at 200 ng/mL. A stability study demonstrates the performance of all four FTS brands was only slightly affected after 30 days of storage at two extreme environmental conditions. Fentanyl-related substances are also evaluated using the Rapid Response FTS, which showed high cross-reactivity with para-fluorofentanyl and acetylfentanyl, but lower with ortho-chlorofentanyl, carfentanil, and 4-ANPP. Users should be aware that FTS may give false-negative results even when potentially dangerous levels of carfentanil are present. When testing other common drugs, adulterants, and diluents frequently encountered in seized tablets, concentration-dependent results were obtained and multiple instances of false positives were recorded.
引用
收藏
页码:1555 / 1569
页数:15
相关论文
共 50 条
  • [1] Cross-Reactivity of Acetylfentanyl and Risperidone With a Fentanyl Immunoassay
    Wang, Bei-Tzu
    Colby, Jennifer M.
    Wu, Alan H. B.
    Lynch, Kara L.
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2014, 38 (09) : 672 - 675
  • [2] Understanding sensitivity and cross-reactivity of xylazine lateral flow immunoassay test strips for drug checking applications
    Sisco, Edward
    Nestadt, Danielle F.
    Bloom, Madeline B.
    Schneider, Kristin E.
    Elkasabany, Rae A.
    Rouhani, Saba
    Sherman, Susan G.
    DRUG TESTING AND ANALYSIS, 2023, 16 (09) : 942 - 947
  • [3] Disopyramide cross-reactivity in a commercial immunoassay reagent for methadone
    Moorman, P
    McCoy, M
    Hague, B
    Huge, D
    JOURNAL OF ANALYTICAL TOXICOLOGY, 1999, 23 (04) : 299 - 300
  • [4] Immunoassay Cross-Reactivity of Phenylephrine and Methamphetamine
    Curtin, Lindsay B.
    Cawley, Michael J.
    PHARMACOTHERAPY, 2012, 32 (05): : E98 - E102
  • [5] Determination of Designer Drug Cross-Reactivity on Five Commercial Immunoassay Screening Kits
    Regester, Laura E.
    Chmiel, Jeffrey D.
    Holler, Justin M.
    Vorce, Shawn P.
    Levine, Barry
    Bosy, Thomas Z.
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2015, 39 (02) : 144 - 151
  • [6] Assessment of Risperidone cross-reactivity in two fentanyl point of care test devices
    Kyle, Barry
    Boyd, Jessica
    Pickersgill, Robin
    Balion, Cynthia
    CLINICAL BIOCHEMISTRY, 2018, 61 : 62 - 62
  • [7] QUANTIFICATION OF SIROLIMUS AND EVEROLIMUS BY IMMUNOASSAY TECHNIQUES: TEST SPECIFICITY AND CROSS-REACTIVITY EVALUATION
    Pieri, M.
    Miraglia, N.
    Gentile, A.
    Polichetti, G.
    Castiglia, L.
    Federico, S.
    Sabbatini, M.
    Basile, V.
    Tarantino, G.
    Acampora, A.
    Capone, D.
    INTERNATIONAL JOURNAL OF IMMUNOPATHOLOGY AND PHARMACOLOGY, 2008, 21 (03) : 585 - 594
  • [8] Validation and Cross-Reactivity Data for Fentanyl Analogs With the Immunalysis Fentanyl ELISA
    Guerrieri, Davide
    Kjellqvist, Fanny
    Kronstrand, Robert
    Green, Henrik
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2019, 43 (01) : 18 - 24
  • [9] FLUORESCENCE POLARIZATION IMMUNOASSAY CROSS-REACTIVITY FOR DIGOXIN
    GARRELTS, JC
    DRUG INTELLIGENCE & CLINICAL PHARMACY, 1987, 21 (04): : 381 - 382
  • [10] CONTACT SENSITIVITY AND CROSS-REACTIVITY OF BUDESONIDE
    NODA, H
    MATSUNAGA, K
    NODA, T
    ABE, M
    OHTANI, T
    SHIMIZU, Y
    ASAHI, K
    IIDA, Y
    TAKIGAMI, N
    MASUTANI, M
    UEDA, H
    CONTACT DERMATITIS, 1993, 28 (04) : 212 - 215