Validation and Cross-Reactivity Data for Fentanyl Analogs With the Immunalysis Fentanyl ELISA

被引:23
|
作者
Guerrieri, Davide [1 ]
Kjellqvist, Fanny [2 ]
Kronstrand, Robert [1 ,2 ]
Green, Henrik [1 ,2 ]
机构
[1] Linkoping Univ, Div Drug Res, Dept Med & Hlth Sci, SE-58185 Linkoping, Sweden
[2] Natl Board Forens Med, Dept Forens Genet & Forens Toxicol, Artillerigatan 12, SE-58758 Linkoping, Sweden
关键词
POSTMORTEM; RECEPTOR;
D O I
10.1093/jat/bky060
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Every year new fentanyl analog compounds, or fentanyls, appear on the drug scene. Development of immunoassays dedicated for screening individual molecules is challenging due to the short-lived presence of these compounds on the recreational drug market. Therefore, we investigated the detecting capabilities of the immunalysis fentanyl direct enzyme-linked immunosorbent assay (ELISA) kit against fentanyl in whole blood, and determined the cross-reactivity of nine fentanyl analogs (2-fluorofentanyl, acetylfentanyl, acrylfentanyl, carfentanil, cyclopropylfentanyl, tetrahydrofuranylfentanyl, furanylfentanyl, ocfentanil, valerylfentanyl) to confirm its validity for the general screening of fentanyls. Immunalysis ELISA assay was used to test whole blood samples fortified with fentanyl on a TECAN Freedom EVOlyzer platform, according to manufacturer specifications. The kit successfully was validated for fentanyl screening with a cutoff set at 0.5 ng/mL, and all tested analogs, with the exclusion of carfentanil, were detected. The lowest cross-reactivity with the kit was obtained with furanylfentanyl (20% +/- 1, 95% confidence intervals (CI)) and 4-fluoroisobutyrfentanyl (25% +/- 1, 95% CI), while the highest was recorded using acetylfentanyl (99% +/- 11, 95% CI) and acrylfentanyl (94% +/- 10, 95% CI). Post-mortem samples containing fentanyl, acrylfentanyl, cyclopropylfentanyl, THF-fentanyl and 4-fluoroisobutyrfentanyl were screened, and sensitivity and specificity of each analog were calculated. Positive screening results were generated by all post-mortem cases containing fentanyl (n = 14), acrylfentanyl (n = 11), cyclopropylfentanyl (n = 14), tetrahydrofuranylfentanyl (n = 13) and 4-fluoroisobutyrfentanyl (n = 10). Concentration of post-mortem fentanyl samples ranged from 0.5 ng/mL (cutoff) to 230 ng/mL, while the range for analogs was 3.4-36 ng/mL (cyclopentylfentanyl), 0.76-370 ng/mL (4-fluoroisobutyrfentanyl), 0.02-12 ng/mL (acrylfentanyl) and 2-26 ng/mL (tetrahydrofuranylfentanyl). The immunalysis fentanyl direct ELISA kit was successfully validated and showed significant cross-reactivity for all tested fentanyls, except carfentanil, making it a suitable technique for fentanyl and fentanyl analogs screening.
引用
收藏
页码:18 / 24
页数:7
相关论文
共 50 条
  • [1] Detection of 58 fentanyl analogs using ARK fentanyl II and Immunalysis fentanyl immunoassays
    Williams, Grace R.
    Akala, Modesola
    Wolf, Carl E.
    CLINICAL BIOCHEMISTRY, 2023, 113 : 45 - 51
  • [2] Cross-Reactivity of Acetylfentanyl and Risperidone With a Fentanyl Immunoassay
    Wang, Bei-Tzu
    Colby, Jennifer M.
    Wu, Alan H. B.
    Lynch, Kara L.
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2014, 38 (09) : 672 - 675
  • [3] MOLECULAR MODELING - A TOOL FOR PREDICTING CROSS-REACTIVITY OF FENTANYL DERIVATIVES AGAINST FENTANYL ANTIBODIES
    NUGIEL, DA
    SOMA, LR
    KELLER, L
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1991, 201 : 14 - COMP
  • [4] DETECTION OF FENTANYL AND ITS ANALOGS BY ELISA
    RUANGYUTTIKARN, W
    MOODY, DE
    LAW, MY
    ROLLINS, DE
    FASEB JOURNAL, 1988, 2 (06): : A1807 - A1807
  • [5] Assessment of Risperidone cross-reactivity in two fentanyl point of care test devices
    Kyle, Barry
    Boyd, Jessica
    Pickersgill, Robin
    Balion, Cynthia
    CLINICAL BIOCHEMISTRY, 2018, 61 : 62 - 62
  • [6] Evaluating the sensitivity, stability, and cross-reactivity of commercial fentanyl immunoassay test strips
    Rodriguez-Cruz, Sandra E.
    JOURNAL OF FORENSIC SCIENCES, 2023, 68 (05) : 1555 - 1569
  • [7] Quantitative Raman Cross-Sections and Band Assignments for Fentanyl and Fentanyl Analogs
    Wilcox, Phillip G.
    Emmons, Erik D.
    Pardoe, Ian J.
    Kline, Neal D.
    Guicheteau, Jason A.
    APPLIED SPECTROSCOPY, 2023, 77 (05) : 439 - 448
  • [8] Validation of the Neogen® Fentanyl ELISA Kit for Blood and Urine
    Tiscione, Nicholas B.
    Wegner, Kristin
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2017, 41 (04) : 313 - 317
  • [9] HYPERSENSITIVITY AND CROSS-REACTIVITY TO CISPLATIN AND ANALOGS
    SHLEBAK, AA
    CLARK, PI
    GREEN, JA
    CANCER CHEMOTHERAPY AND PHARMACOLOGY, 1995, 35 (04) : 349 - 351
  • [10] Listed for sale: Analyzing data on fentanyl, fentanyl analogs and other novel synthetic opioids on one cryptomarket
    Lamy, Francois R.
    Daniulaityte, Raminta
    Barratt, Monica J.
    Lokala, Usha
    Sheth, Amit
    Carlson, Robert G.
    DRUG AND ALCOHOL DEPENDENCE, 2020, 213