Evaluating the sensitivity, stability, and cross-reactivity of commercial fentanyl immunoassay test strips

被引:4
|
作者
Rodriguez-Cruz, Sandra E. [1 ,2 ]
机构
[1] Drug Enforcement Adm, Special Testing & Res Lab, Dulles, VA USA
[2] Drug Enforcement Adm, Special Testing & Res Lab, 22624 Dulles Summit Ct, Dulles, VA 20166 USA
关键词
fentanyl; fentanyl test strips; fentanyl-related substance; harm reduction; lateral-flow immunoassay; opioid epidemic; seized drugs;
D O I
10.1111/1556-4029.15332
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
Illicit fentanyl has flooded the United States' drug market, increasing the risk of overdose and poisonings throughout the general population and accidental exposure among law enforcement officers confiscating the increasing number of seizures. Fentanyl test strips (FTS) are used to obtain presumptive information about the presence of fentanyl in a suspected sample. However, their adoption by law enforcement personnel and seized-drug analysts has been limited because most products are advertised for urine testing, not for assays using water solutions. This study presents an evaluation of four commercial FTS: Rapid Response from BTNX, Inc.; T-Dip Fentanyl (FTY) Urine Dip Cards obtained from ; Premier BioDip FYL10 from Premier Biotech Inc.; and MobileDetect Fentanyl strips from DetectaChem, Inc. Performance characteristics curves were used to compare the products' sensitivity, showing that all can reliably detect fentanyl in aqueous solutions at concentrations below 1 & mu;g/mL, with some of the tests able to reliably detect the drug at 200 ng/mL. A stability study demonstrates the performance of all four FTS brands was only slightly affected after 30 days of storage at two extreme environmental conditions. Fentanyl-related substances are also evaluated using the Rapid Response FTS, which showed high cross-reactivity with para-fluorofentanyl and acetylfentanyl, but lower with ortho-chlorofentanyl, carfentanil, and 4-ANPP. Users should be aware that FTS may give false-negative results even when potentially dangerous levels of carfentanil are present. When testing other common drugs, adulterants, and diluents frequently encountered in seized tablets, concentration-dependent results were obtained and multiple instances of false positives were recorded.
引用
收藏
页码:1555 / 1569
页数:15
相关论文
共 50 条
  • [11] Cross-reactivity in Cryptococcus antigen latex agglutination test in two commercial kits
    Tone, Kazuya
    Umeda, Yoshiko
    Makimura, Koichi
    MEDICAL MYCOLOGY, 2016, 54 (04) : 439 - 443
  • [12] Immunoassay for simazine and atrazine with low cross-reactivity for propazine
    Wortberg, M
    Goodrow, MH
    Gee, SJ
    Hammock, BD
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1996, 44 (08) : 2210 - 2219
  • [13] Cross-Reactivity of Chloroquine and Hydroxychloroquine With DRI Amphetamine Immunoassay
    Gomila, Isabel
    Quesada, Loreto
    Lopez-Corominas, Victoria
    Fernandez, Julia
    Servera, Miguel A.
    Sahuquillo, Laura
    Dastis, Macarena
    Torrents, Albert
    Barcelo, Bernardino
    THERAPEUTIC DRUG MONITORING, 2017, 39 (02) : 192 - 196
  • [14] CROSS-REACTIVITY OF DIHYDRODIGOXIN WITH A COMMERCIAL DIGOXIN KIT
    OGE, EK
    POLONUS, PA
    CLINICAL CHEMISTRY, 1978, 24 (06) : 1086 - 1086
  • [15] Prediction of Immunoassay Cross-Reactivity Using Chemoinformatic Methods
    Krasowski, Matthew D.
    Ekins, Sean
    Kortagere, Sandhya
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2010, 134 (03) : 502 - 502
  • [16] Cephalosporin Cross-Reactivity In Skin Test
    Lee, Jong-Myung
    Kim, Min-Hye
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2014, 133 (02) : AB262 - AB262
  • [17] CROSS-REACTIVITY OF A COMMERCIAL CHEMILUMINESCENCE IMMUNOASSAY FOR HUMAN CHORIONIC-GONADOTROPIN WITH THE FREE BETA-SUBUNIT
    LUPPA, P
    SPOTTL, G
    SALLER, B
    NEUMEIER, D
    MANN, K
    JOURNAL OF BIOLUMINESCENCE AND CHEMILUMINESCENCE, 1992, 7 (03): : 195 - 201
  • [18] Cross-Reactivity of Paracoccidioides brasiliensis, Histoplasma capsulatum, and Cryptococcus Species in the Commercial Platelia Aspergillus Enzyme Immunoassay
    Xavier, Melissa O.
    Pasqualotto, Alessandro C.
    Cardoso, Isabel Cristina E.
    Severo, Luiz Carlos
    CLINICAL AND VACCINE IMMUNOLOGY, 2009, 16 (01) : 132 - 133
  • [19] MOLECULAR MODELING - A TOOL FOR PREDICTING CROSS-REACTIVITY OF FENTANYL DERIVATIVES AGAINST FENTANYL ANTIBODIES
    NUGIEL, DA
    SOMA, LR
    KELLER, L
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1991, 201 : 14 - COMP
  • [20] Cross-Reactivity of Antibodies in Some Commercial Deoxynivalenol Test Kits against Some Fusariotoxins
    Tangni, Emmanuel K.
    Motte, Jean-Claude
    Callebaut, Alfons
    Pussemier, Luc
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2010, 58 (24) : 12625 - 12633