Evaluating the sensitivity, stability, and cross-reactivity of commercial fentanyl immunoassay test strips

被引:4
|
作者
Rodriguez-Cruz, Sandra E. [1 ,2 ]
机构
[1] Drug Enforcement Adm, Special Testing & Res Lab, Dulles, VA USA
[2] Drug Enforcement Adm, Special Testing & Res Lab, 22624 Dulles Summit Ct, Dulles, VA 20166 USA
关键词
fentanyl; fentanyl test strips; fentanyl-related substance; harm reduction; lateral-flow immunoassay; opioid epidemic; seized drugs;
D O I
10.1111/1556-4029.15332
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
Illicit fentanyl has flooded the United States' drug market, increasing the risk of overdose and poisonings throughout the general population and accidental exposure among law enforcement officers confiscating the increasing number of seizures. Fentanyl test strips (FTS) are used to obtain presumptive information about the presence of fentanyl in a suspected sample. However, their adoption by law enforcement personnel and seized-drug analysts has been limited because most products are advertised for urine testing, not for assays using water solutions. This study presents an evaluation of four commercial FTS: Rapid Response from BTNX, Inc.; T-Dip Fentanyl (FTY) Urine Dip Cards obtained from ; Premier BioDip FYL10 from Premier Biotech Inc.; and MobileDetect Fentanyl strips from DetectaChem, Inc. Performance characteristics curves were used to compare the products' sensitivity, showing that all can reliably detect fentanyl in aqueous solutions at concentrations below 1 & mu;g/mL, with some of the tests able to reliably detect the drug at 200 ng/mL. A stability study demonstrates the performance of all four FTS brands was only slightly affected after 30 days of storage at two extreme environmental conditions. Fentanyl-related substances are also evaluated using the Rapid Response FTS, which showed high cross-reactivity with para-fluorofentanyl and acetylfentanyl, but lower with ortho-chlorofentanyl, carfentanil, and 4-ANPP. Users should be aware that FTS may give false-negative results even when potentially dangerous levels of carfentanil are present. When testing other common drugs, adulterants, and diluents frequently encountered in seized tablets, concentration-dependent results were obtained and multiple instances of false positives were recorded.
引用
收藏
页码:1555 / 1569
页数:15
相关论文
共 50 条
  • [21] EXAMINATION OF THE CROSS-REACTIVITY AND SENSITIVITY OF A COMMERCIAL FDP-LATEX AGGLUTINATION-TEST COMPARED WITH PURE CANINE FIBRINOGENDEGRADATION PRODUCTS
    WOLLING, H
    MISCHKE, R
    KLEINTIERPRAXIS, 1995, 40 (01): : 23 - 32
  • [22] Selectivity and sensitivity of urine fentanyl test strips to detect fentanyl analogues in illicit drugs
    Bergh, Marianne Skov-Skov
    Oiestad, Ase Marit Leere
    Baumann, Michael H.
    Bogen, Inger Lise
    INTERNATIONAL JOURNAL OF DRUG POLICY, 2021, 90
  • [23] Cross-Reactivity of Nefopam and Its Metabolites with Benzodiazepine EMIT Immunoassay
    El-Haj, Babiker
    Al-Amri, Abdulkader
    Ali, Heyam
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2008, 32 (09) : 790 - 792
  • [24] Galactomannan Enzymatic Immunoassay Cross-Reactivity Caused by Prototheca Species
    Van den Bossche, D.
    De Bel, A.
    Hendrickx, M.
    De Becker, A.
    Jacobs, R.
    Naessens, A.
    Pierard, D.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2012, 50 (10) : 3371 - 3373
  • [25] EVALUATION OF A NONISOTOPIC IMMUNOASSAY FOR LUTROPIN WITH NO SIGNIFICANT CROSS-REACTIVITY WITH CHORIOGONADOTROPIN
    KHOSRAVI, MJ
    SHANKARAN, P
    CLINICAL CHEMISTRY, 1990, 36 (06) : 1101 - 1101
  • [26] DIGOXIN IMMUNOASSAY THAT AVOIDS CROSS-REACTIVITY FROM CHINESE MEDICINES
    FUSHIMI, R
    YAMANISHI, H
    INOUE, M
    IYAMA, S
    AMINO, N
    CLINICAL CHEMISTRY, 1995, 41 (04) : 621 - 621
  • [27] An immunoassay for simazine and atrazine with low cross-reactivity for propazine.
    Goodrow, MH
    Wortberg, M
    Sugawara, Y
    Hammock, BD
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1996, 211 : 81 - AGRO
  • [28] Cross-reactivity in the Platelia™ Aspergillus enzyme immunoassay caused by blastomycosis
    Van der Veer, Jon
    Lewis, Roshan J.
    Emtiazjoo, Amir M.
    Allen, Stephen D.
    Wheat, L. Joseph
    Hage, Chadi A.
    MEDICAL MYCOLOGY, 2012, 50 (04) : 396 - 398
  • [29] Development of a displacement immunoassay by exploiting cross-reactivity of a monoclonal antibody
    Gerdes, M
    Meusel, M
    Spencer, F
    ANALYTICAL BIOCHEMISTRY, 1997, 252 (01) : 198 - 204
  • [30] Cross-Reactivity of Tapentadol Specimens with DRI Methadone Enzyme Immunoassay
    Collins, Ayodele A.
    Merritt, A. Paola
    Bourland, James A.
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2012, 36 (08) : 582 - 587