An audit of patient radiation doses in interventional radiology at a South African hospital

被引:1
|
作者
Slave, Oneile [1 ]
Mahomed, Nasreen [1 ]
机构
[1] Univ Witwatersrand, Fac Hlth Sci, Dept Radiol, Johannesburg, South Africa
来源
SA JOURNAL OF RADIOLOGY | 2023年 / 27卷 / 01期
关键词
Interventional radiology; diagnostic reference level; kerma air product; reference point air kerma; fluoroscopy time; DIAGNOSTIC REFERENCE LEVELS; MULTICENTER; EXPOSURE; IR;
D O I
10.4102/sajr.v27i1.2559
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Interventional radiology (IR) is becoming more relevant in patient care and is associated with increased patient radiation exposure and radiation-induced adverse effects. Diagnostic reference levels (DRLs) are crucial for radiation control. There is a paucity of published DRLs for IR in South Africa and sub-Saharan Africa. Objectives: This study aimed to determine local DRLs for fluoroscopically-guided IR procedures and compare the achieved DRLs with published local and international DRLs. Method: Retrospective, descriptive, single-centre study. Kerma air product (KAP), reference point air kerma (Ka,r) and fluoroscopy time (FT) were collected for patients (12 years and older) who underwent IR procedures at a university hospital from 01 January 2019 to 31 December 2019. The 75th percentile of the distribution of each dose parameter (KAP, Ka,r and FT) per procedure was calculated and taken as the local diagnostic reference levels (LDRL). The established LDRLs were compared to published DRLs. Results: A total of 564 cases were evaluated. The 13 most frequent procedures (with 15 or more cases) represented 86.1% (487/564). Percutaneous transhepatic biliary drainage was the most common procedure (n = 146, 25.9%). Diagnostic cerebral angiogram DRLs exceeded the published DRL data ranges for all parameters (DRL 209.3), and interventional cerebral angiogram exceeded published ranges (DRL 275). Uterine artery embolisation (UAE) exceeded these ranges for KAP and Ka,r. (KAP-954.9 Gy/cm2, Ka,r-2640.8 mGy). Conclusion: The LDRLs for diagnostic cerebral angiogram, interventional cerebral angiogram and UAE exceeded published international DRL ranges. These procedures require radiation optimisation as recommended by the International Commission on Radiological Protection (ICRP). Contribution: In addition to informing radiation protection practices at the level of the institution, the established LDRLs contribute towards Regional and National DRLs.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] EXTREMITY DOSES DURING INTERVENTIONAL RADIOLOGY
    ODURNY, A
    CLINICAL RADIOLOGY, 1990, 42 (02) : 142 - 142
  • [22] EXTREMITY DOSES DURING INTERVENTIONAL RADIOLOGY
    RAMSDALE, ML
    WALKER, WJ
    HORTON, PW
    CLINICAL RADIOLOGY, 1990, 41 (01) : 34 - 36
  • [23] Indicators for the finger doses in interventional radiology
    Stranden, Erling
    Seske, Tonje
    Widmark, Anders
    RADIATION PROTECTION DOSIMETRY, 2007, 124 (02) : 164 - 166
  • [24] Assessment of occupational radiation doses to eye lens during interventional radiology procedures
    Ali, Amir
    Al-Nuaimi, Meshari
    Khan, Banaras
    Burki, Shamsullah
    Nishtar, Tahira
    Yaseen, Muhammad
    Shah, Syed Sher Azam
    Irfan, Muhammad
    RADIATION PHYSICS AND CHEMISTRY, 2024, 225
  • [25] High filtration in interventional practices reduces patient radiation doses but not always scatter radiation doses
    Sanchez, Roberto M.
    Vano, Eliseo
    Salinas, Pablo
    Gonzalo, Nieves
    Escaned, Javier
    Fernandez, Jose M.
    BRITISH JOURNAL OF RADIOLOGY, 2021, 94 (1117):
  • [26] CONTEMPORARY RADIATION DOSES IN INTERVENTIONAL CARDIOLOGY: A NATIONWIDE STUDY OF PATIENT DOSES IN FINLAND
    Jarvinen, Jukka
    Sierpowska, Joanna
    Siiskonen, Teemu
    Jarvinen, Hannu
    Kiviniemi, Tuomas
    Rissanen, Tuomas T.
    Matikka, Hanna
    Niskanen, Eini
    Hurme, Saija
    Larjava, Heli R. S.
    Makela, Timo J.
    Strengell, Satu
    Eskola, Markku
    Parviainen, Teuvo
    Hallinen, Elina
    Pirinen, Markku
    Kivela, Antti
    Teras, Mika
    RADIATION PROTECTION DOSIMETRY, 2019, 185 (04) : 483 - 493
  • [27] Patient doses in interventional radiology:: Accuracy in measurement and proper use of nomenclature -: response
    Ruiz-Cruces, R
    Pérez-Martínez, M
    RADIOLOGY, 1998, 209 (02) : 590 - 590
  • [28] Impact of the incorrect use of lead drapes on staff and patient doses in interventional radiology
    Lima, Thiago V. M.
    Del Castillo, Tomas Reyes
    Heinrich, Mirjam
    Zihlmann, Stephanie
    Benitez, Ruben Lopez
    Roos, Justus E.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2022, 42 (02)
  • [29] Interventional Radiology Procedures: Current Issues in Patient Doses and Image Quality Optimization
    Compagnone, Gaetano
    Fabbri, Emma
    CURRENT MEDICAL IMAGING, 2009, 5 (03) : 159 - 166
  • [30] Monte Carlo calculations for reporting patient organ doses from interventional radiology
    Huo, Wanli
    Feng, Mang
    Pit, Yifei
    Chen, Zhi
    Gao, Yiming
    Xu, X. George
    ICRS-13 & RPSD-2016, 13TH INTERNATIONAL CONFERENCE ON RADIATION SHIELDING & 19TH TOPICAL MEETING OF THE RADIATION PROTECTION AND SHIELDING DIVISION OF THE AMERICAN NUCLEAR SOCIETY - 2016, 2017, 153