CONTEMPORARY RADIATION DOSES IN INTERVENTIONAL CARDIOLOGY: A NATIONWIDE STUDY OF PATIENT DOSES IN FINLAND

被引:12
|
作者
Jarvinen, Jukka [1 ,2 ,3 ,4 ]
Sierpowska, Joanna [5 ]
Siiskonen, Teemu [6 ]
Jarvinen, Hannu [6 ]
Kiviniemi, Tuomas [1 ,2 ]
Rissanen, Tuomas T. [5 ]
Matikka, Hanna [7 ]
Niskanen, Eini [8 ]
Hurme, Saija [9 ]
Larjava, Heli R. S. [10 ]
Makela, Timo J. [11 ]
Strengell, Satu [12 ]
Eskola, Markku [13 ,14 ]
Parviainen, Teuvo [6 ]
Hallinen, Elina [6 ]
Pirinen, Markku [6 ]
Kivela, Antti [7 ]
Teras, Mika [4 ,15 ]
机构
[1] Turku Univ Hosp, Turku Heart Ctr, Dept Cardiol, Turku, Finland
[2] Univ Turku, Turku, Finland
[3] Turku Univ Hosp, Med Imaging Ctr Southwest Finland, Dept Radiol, Turku, Finland
[4] Turku Univ Hosp, Dept Med Phys, Turku, Finland
[5] Cent Hosp Northern Karelia, Dept Radiol, Joensuu, Finland
[6] Radiat & Nucl Safety Author, Helsinki, Finland
[7] Kuopio Univ Hosp, Imaging Ctr, Dept Radiol, Kuopio, Finland
[8] Vaasa Cent Hosp, Dept Radiol, Vaasa, Finland
[9] Univ Turku, Dept Biostat, Turku, Finland
[10] Cent Finland Hlth Care Dist, Dept Med Imaging, Jyvaskyla, Finland
[11] Oulu Univ Hosp, Dept Internal Med, Div Cardiol, Oulu, Finland
[12] Helsinki Univ Hosp, Heart & Lung Ctr, Dept Cardiol, Cardiol Div, Helsinki, Finland
[13] Tampere Univ Hosp, Heart Hosp, Dept Cardiol, Tampere, Finland
[14] Univ Tampere, Fac Med & Life Sci, Tampere, Finland
[15] Univ Turku, Inst Biomed, Dept Biomed, Turku, Finland
关键词
DIAGNOSTIC REFERENCE LEVELS; CORONARY-ANGIOGRAPHY; RADIOLOGY PROCEDURES; RAD-IR; ANGIOPLASTY; EXPOSURE; PREDICTORS; TRENDS; LEVEL;
D O I
10.1093/rpd/ncz041
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The amount of interventional procedures such as percutaneous coronary intervention (PCI), transcatheter aortic valve implantation (TAVI), pacemaker implantation (PI) and ablations has increased within the previous decade. Simultaneously, novel fluoroscopy mainframes enable lower radiation doses for patients and operators. Therefore, there is a need to update the existing diagnostic reference levels (DRLs) and propose new ones for common or recently introduced procedures. We sought to assess patient radiation doses in interventional cardiology in a large sample from seven hospitals across Finland between 2014 and 2016. Data were used to set updated national DRLs for coronary angiographies (kerma-air product (KAP) 30 Gycm(2)) and PCIs (KAP 75 cm(2)), and novel levels for PIs (KAP 3.5 Gycm(2)), atrial fibrillation ablation procedures (KAP 25 Gycm(2)) and TAVI (KAP 90 Gycm(2)). Tentative KAP values were set for implantations of cardiac resynchronization therapy devices (CRT, KAP 22 Gycm(2)), electrophysiological treatment of atrioventricular nodal re-entry tachycardia (6 Gycm(2)) and atrial flutter procedures (KAP 16 Gycm(2)). The values for TAVI and CRT device implantation are published for the first time on national level. Dose from image acquisition (cine) constitutes the major part of the total dose in coronary and atrial fibrillation ablation procedures. For TAVI, patient weight is a good predictor of patient dose.
引用
收藏
页码:483 / 493
页数:11
相关论文
共 50 条
  • [1] CONTEMPORARY RADIATION DOSES IN INTERVENTIONAL CARDIOLOGY: A NATIONWIDE STUDY OF PATIENT SKIN DOSES IN FINLAND
    Jarvinen, Jukka
    Sierpowska, Joanna
    Siiskonen, Teemu
    Husso, Minna
    Jarvinen, Hannu
    Kiviniemi, Tuomas
    Rissanen, Tuomas T.
    Lindholm, Carita
    Matikka, Hanna
    Larjava, Heli R. S.
    Makela, Timo J.
    Strengell, Satu
    Eskola, Markku
    Parviainen, Teuvo
    Hallinen, Elina
    Pirinen, Markku
    Kivela, Antti
    Teras, Mika
    RADIATION PROTECTION DOSIMETRY, 2020, 188 (02) : 181 - 190
  • [2] Patient Radiation Doses in Interventional Cardiology Procedures
    Pantos, Ioannis
    Patatoukas, Georgios
    Katritsis, Demosthenes G.
    Efstathopoulos, Efstathios
    CURRENT CARDIOLOGY REVIEWS, 2009, 5 (01) : 1 - 11
  • [3] Patient Radiation Doses in Interventional Cardiology Procedure
    Hiswara, E.
    Kartikasari, D.
    Nuraeni, N.
    Sofyan, H.
    Sandy, K. Y. P.
    ATOM INDONESIA, 2022, 48 (02) : 81 - 85
  • [4] Radiation doses to patients in interventional cardiology
    Benini, A.
    Pedersen, F.
    Helqvist, S.
    Kastrup, J.
    Kelbaek, H.
    Saunamaki, K.
    Jorgensen, E.
    EUROPEAN HEART JOURNAL, 2009, 30 : 537 - 537
  • [5] Staff Radiation Doses in Interventional Cardiology: Correlation With Patient Exposure
    Vano, Eliseo
    Ubeda, Carlos
    Leyton, Fernando
    Miranda, Patricia
    Gonzalez, Luciano
    PEDIATRIC CARDIOLOGY, 2009, 30 (04) : 409 - 413
  • [6] Patient radiation doses in paediatric interventional cardiology and optimization actions
    Ubeda, Carlos
    Vano, Eliseo
    Riquelme, Nemorino
    Aguirre, Daniel
    Vasquez, Hector
    Chavez, Cristian
    Dalmazzo, Dandaro
    RADIATION PHYSICS AND CHEMISTRY, 2020, 168
  • [7] Patient radiation doses in paediatric interventional cardiology procedures: a review
    Harbron, R. W.
    Dreuil, S.
    Bernier, M-O
    Pearce, M. S.
    Thierry-Chef, I.
    Chapple, C-L
    Baysson, H.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2016, 36 (04) : R131 - R144
  • [8] Staff Radiation Doses in Interventional Cardiology: Correlation With Patient Exposure
    Eliseo Vano
    Carlos Ubeda
    Fernando Leyton
    Patricia Miranda
    Luciano Gonzalez
    Pediatric Cardiology, 2009, 30 : 409 - 413
  • [9] Evaluation of patient doses and lens radiation doses to interventional cardiologists in a nationwide survey in Chile
    Ubeda, Carlos
    Vano, Eliseo
    Gonzalez, Luciano
    Miranda, Patricia
    Valenzuela, Edith
    Vergara, Francisco
    Guarda, Eduardo
    RADIATION PROTECTION DOSIMETRY, 2013, 157 (01) : 36 - 43
  • [10] Radiation doses in paediatric interventional cardiology procedures
    Tsapaki, Virginia
    Kottou, Sofia
    Korniotis, Sarantis
    Nikolaki, Niki
    Rammos, Spyridon
    Apostolopoulou, Sotiria C.
    RADIATION PROTECTION DOSIMETRY, 2008, 132 (04) : 390 - 394