The Zhu-Lu formula: a machine learning-based intraocular lens power calculation formula for highly myopic eyes

被引:6
|
作者
Guo, Dongling [1 ,2 ,3 ,4 ,5 ]
He, Wenwen [1 ,2 ,3 ,4 ,5 ]
Wei, Ling [1 ,2 ,3 ,4 ,5 ]
Song, Yunxiao [6 ]
Qi, Jiao [1 ,2 ,3 ,4 ,5 ]
Yao, Yunqian [1 ,2 ,3 ,4 ,5 ]
Chen, Xu [7 ]
Huang, Jinhai [1 ,2 ,8 ]
Lu, Yi [1 ,2 ,3 ,4 ,5 ]
Zhu, Xiangjia [1 ,2 ,3 ,4 ,5 ]
机构
[1] Fudan Univ, Eye & ENT Hosp, Inst Eye, Shanghai 200031, Peoples R China
[2] Fudan Univ, Eye & ENT Hosp, Dept Ophthalmol, Shanghai 200031, Peoples R China
[3] Fudan Univ, NHC Key Lab Myopia, Shanghai, Peoples R China
[4] Chinese Acad Med Sci, Key Lab Myopia, Shanghai, Peoples R China
[5] Shanghai Key Lab Visual Impairment & Restorat, Shanghai, Peoples R China
[6] Univ Illinois, Champaign, IL USA
[7] Shanghai Aier Eye Hosp, Shanghai, Peoples R China
[8] Wenzhou Med Univ, Hosp Eye, Wenzhou, Peoples R China
基金
中国国家自然科学基金;
关键词
Machine learning; IOL power calculation; High myopia; Prediction error; REFRACTIVE OUTCOMES; ACCURACY; BIOMETRY; SRK/T;
D O I
10.1186/s40662-023-00342-5
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
BackgroundTo develop a novel machine learning-based intraocular lens (IOL) power calculation formula for highly myopic eyes.MethodsA total of 1828 eyes (from 1828 highly myopic patients) undergoing cataract surgery in our hospital were used as the internal dataset, and 151 eyes from 151 highly myopic patients from two other hospitals were used as external test dataset. The Zhu-Lu formula was developed based on the eXtreme Gradient Boosting and the support vector regression algorithms. Its accuracy was compared in the internal and external test datasets with the Barrett Universal II (BUII), Emmetropia Verifying Optical (EVO) 2.0, Kane, Pearl-DGS and Radial Basis Function (RBF) 3.0 formulas.ResultsIn the internal test dataset, the Zhu-Lu, RBF 3.0 and BUII ranked top three from low to high taking into account standard deviations (SDs) of prediction errors (PEs). The Zhu-Lu and RBF 3.0 showed significantly lower median absolute errors (MedAEs) than the other formulas (all P < 0.05). In the external test dataset, the Zhu-Lu, Kane and EVO 2.0 ranked top three from low to high considering SDs of PEs. The Zhu-Lu formula showed a comparable MedAE with BUII and EVO 2.0 but significantly lower than Kane, Pearl-DGS and RBF 3.0 (all P < 0.05). The Zhu-Lu formula ranked first regarding the percentages of eyes within +/- 0.50 D of the PE in both test datasets (internal: 80.61%; external: 72.85%). In the axial length subgroup analysis, the PE of the Zhu-Lu stayed stably close to zero in all subgroups.ConclusionsThe novel IOL power calculation formula for highly myopic eyes demonstrated improved and stable predictive accuracy compared with other artificial intelligence-based formulas.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Metaanalysis of intraocular lens power calculation after laser refractive surgery in myopic eyes
    Chen, Xu
    Yuan, Fei
    Wu, Lianqun
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (01): : 163 - 170
  • [42] Effect of optional biometric parameters in the Kane formula on intraocular lens power calculation
    Li, Xiao-Yu
    Liao, Xuan
    Lin, Jia
    Lan, Chang-Jun
    Tan, Qing-Qing
    PLOS ONE, 2023, 18 (08):
  • [43] Accuracy of a universal theoretical formula for power calculation in pediatric intraocular lens implantation
    Eppley, Sarah E.
    Arnold, Benjamin F.
    Tadros, Dina
    Pasricha, Neel
    Campomanes, Alejandra G. de Alba
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (05): : 599 - 605
  • [44] FACTORS INFLUENCING THE ACCURACY OF THE SRK FORMULA IN THE INTRAOCULAR-LENS POWER CALCULATION
    KALOGEROPOULOS, C
    ASPIOTIS, M
    STEFANIOTOU, M
    PSILAS, K
    DOCUMENTA OPHTHALMOLOGICA, 1994, 85 (03) : 223 - 242
  • [45] A new formula for intraocular lens power calculation after refractive corneal surgery
    Camellin, M
    Calossi, A
    JOURNAL OF REFRACTIVE SURGERY, 2006, 22 (02) : 187 - 199
  • [46] DEVELOPMENT OF THE SRK/T INTRAOCULAR-LENS IMPLANT POWER CALCULATION FORMULA
    RETZLAFF, JA
    SANDERS, DR
    KRAFF, MC
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1990, 16 (03): : 333 - 340
  • [47] Performance of a simplified strategy for formula constant optimisation in intraocular lens power calculation
    Langenbucher, Achim
    Wendelstein, Jascha
    Szentmary, Nora
    Cayless, Alan
    Hoffmann, Peter
    Debellmaniere, Guillaume
    Gatinel, Damien
    ACTA OPHTHALMOLOGICA, 2025, 103 (01) : e10 - e18
  • [48] Current accuracy of a simple Gaussian optics-based thin lens intraocular lens power calculation formula
    Klijn, Stijn
    Sicam, Victor Arni
    Reus, Nic J.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [49] Network Meta-analysis of Intraocular Lens Power Calculation Formula Accuracy in 1016 Eyes With Long Axial Length
    Ma, Yiyuan
    Xiong, Ruilin
    Liu, Zhenzhen
    Young, Charlotte aimee
    Wu, Yue
    Zheng, Danying
    Zhang, Xinyu
    Jin, Guangming
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2024, 257 : 178 - 186
  • [50] The PEARL-DGS Formula: The Development of an Open-source Machine Learning-based Thick IOL Calculation Formula
    Debellemaniere, Guillaume
    Dubois, Mathieu
    Gauvin, Mathieu
    Wallerstein, Avi
    Brenner, Luis F.
    Rampat, Radhika
    Saad, Alain
    Gatinel, Damien
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2021, 232 : 58 - 69