The Zhu-Lu formula: a machine learning-based intraocular lens power calculation formula for highly myopic eyes

被引:6
|
作者
Guo, Dongling [1 ,2 ,3 ,4 ,5 ]
He, Wenwen [1 ,2 ,3 ,4 ,5 ]
Wei, Ling [1 ,2 ,3 ,4 ,5 ]
Song, Yunxiao [6 ]
Qi, Jiao [1 ,2 ,3 ,4 ,5 ]
Yao, Yunqian [1 ,2 ,3 ,4 ,5 ]
Chen, Xu [7 ]
Huang, Jinhai [1 ,2 ,8 ]
Lu, Yi [1 ,2 ,3 ,4 ,5 ]
Zhu, Xiangjia [1 ,2 ,3 ,4 ,5 ]
机构
[1] Fudan Univ, Eye & ENT Hosp, Inst Eye, Shanghai 200031, Peoples R China
[2] Fudan Univ, Eye & ENT Hosp, Dept Ophthalmol, Shanghai 200031, Peoples R China
[3] Fudan Univ, NHC Key Lab Myopia, Shanghai, Peoples R China
[4] Chinese Acad Med Sci, Key Lab Myopia, Shanghai, Peoples R China
[5] Shanghai Key Lab Visual Impairment & Restorat, Shanghai, Peoples R China
[6] Univ Illinois, Champaign, IL USA
[7] Shanghai Aier Eye Hosp, Shanghai, Peoples R China
[8] Wenzhou Med Univ, Hosp Eye, Wenzhou, Peoples R China
基金
中国国家自然科学基金;
关键词
Machine learning; IOL power calculation; High myopia; Prediction error; REFRACTIVE OUTCOMES; ACCURACY; BIOMETRY; SRK/T;
D O I
10.1186/s40662-023-00342-5
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
BackgroundTo develop a novel machine learning-based intraocular lens (IOL) power calculation formula for highly myopic eyes.MethodsA total of 1828 eyes (from 1828 highly myopic patients) undergoing cataract surgery in our hospital were used as the internal dataset, and 151 eyes from 151 highly myopic patients from two other hospitals were used as external test dataset. The Zhu-Lu formula was developed based on the eXtreme Gradient Boosting and the support vector regression algorithms. Its accuracy was compared in the internal and external test datasets with the Barrett Universal II (BUII), Emmetropia Verifying Optical (EVO) 2.0, Kane, Pearl-DGS and Radial Basis Function (RBF) 3.0 formulas.ResultsIn the internal test dataset, the Zhu-Lu, RBF 3.0 and BUII ranked top three from low to high taking into account standard deviations (SDs) of prediction errors (PEs). The Zhu-Lu and RBF 3.0 showed significantly lower median absolute errors (MedAEs) than the other formulas (all P < 0.05). In the external test dataset, the Zhu-Lu, Kane and EVO 2.0 ranked top three from low to high considering SDs of PEs. The Zhu-Lu formula showed a comparable MedAE with BUII and EVO 2.0 but significantly lower than Kane, Pearl-DGS and RBF 3.0 (all P < 0.05). The Zhu-Lu formula ranked first regarding the percentages of eyes within +/- 0.50 D of the PE in both test datasets (internal: 80.61%; external: 72.85%). In the axial length subgroup analysis, the PE of the Zhu-Lu stayed stably close to zero in all subgroups.ConclusionsThe novel IOL power calculation formula for highly myopic eyes demonstrated improved and stable predictive accuracy compared with other artificial intelligence-based formulas.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] A Modified Formula for Intraocular Lens Power Calculation Based on Aphakic Refraction in a Pediatric Population
    Jafarinasab, Mohammad-Reza
    Khosravi, Behrooz
    Esfandiari, Hamed
    Hooshmandi, Sadid
    Hassanpour, Kiana
    JOURNAL OF OPHTHALMIC & VISION RESEARCH, 2023, 18 (01) : 34 - 40
  • [32] An Intraocular Lens Power Calculation Formula Based on Optical Coherence Tomography: A Pilot Study
    Tang, Maolong
    Li, Yan
    Huang, David
    JOURNAL OF REFRACTIVE SURGERY, 2010, 26 (06) : 430 - 437
  • [33] SRK-II FORMULA IN THE CALCULATION OF INTRAOCULAR-LENS POWER
    DANG, MS
    RAJ, PPS
    BRITISH JOURNAL OF OPHTHALMOLOGY, 1989, 73 (10) : 823 - 826
  • [34] Preliminary demonstration of a novel intraocular lens power calculation: the O formula
    Goto, So
    Maeda, Naoyuki
    Ohnuma, Kazuhiko
    Lawu, Tjundewo
    Kawasaki, Ryo
    Koh, Shizuka
    Nishida, Kohji
    Noda, Toru
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2022, 48 (11): : 1305 - 1311
  • [35] Efficacy of corneal curvature on the accuracy of 8 intraocular lens power calculation formulas in 302 highly myopic eyes
    Mo, Er
    Feng, Ke
    Li, Qiyuan
    Xu, Jingyuan
    Cen, Jiaying
    Li, Jin
    Zhao, Yun-e
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2023, 49 (12): : 1195 - 1200
  • [36] Intraocular lens calculation formula selection for short eyes: based on axial length and anterior chamber depth
    Gao, Ruoxi
    Zhang, Jiaqing
    Han, Xiaotong
    Huang, Yiguo
    Huang, Ruoxuan
    Ye, Jinfeng
    Wen, Ling
    Qiu, Xiaozhang
    Chen, Xiaoyun
    Tan, Xuhua
    Luo, Lixia
    BMC OPHTHALMOLOGY, 2025, 25 (01)
  • [37] Intraocular lens power calculation in virgin eyes: Accuracy of the Barrett Universal II formula and a Ray tracing software
    Fernandez-Roses, Joaquim
    Lamarca, Jose
    Pinero, David P.
    Barraquer, Rafael, I
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2022, 32 (05) : 2954 - 2960
  • [38] Intraocular lens power calculation formula accuracy: Comparison of 12 formulas for a trifocal hydrophilic intraocular lens
    Rocha-de-Lossada, Carlos
    Colmenero-Reina, Elvira
    Flikier, David
    Castro-Alonso, Francisco-Javier
    Rodriguez-Raton, Alvaro
    Garcia-Madrona, Jose-Luis
    Peraza-Nieves, Jorge
    Sanchez-Gonzalez, Jose-Maria
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2021, 31 (06) : 2981 - 2988
  • [39] Accuracy of new intraocular lens power calculation formula for short and long eyes using segmental refractive indices
    Kato, Yukihito
    Ayaki, Masahiko
    Tamaoki, Akeno
    Tanaka, Yoshiki
    Ichikawa, Kei
    Ichikawa, Kazuo
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2024, 50 (08): : 810 - 815
  • [40] The Development of a Thick-Lens Post-Myopic Laser Vision Correction Intraocular Lens Calculation Formula
    Debellemaniere, Guillaume
    Mechleb, Nicole
    Bernier, Timothte
    Ancel, Jean-marc
    Gauvin, Mathieu
    Wallerstein, Avi
    Saad, Alain
    Gatinel, Damien
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2024, 262 : 40 - 47