Image quality and radiation dose assessment for the clinically applied 16-slice CT scanner using PMMA phantom and quality assurance phantom

被引:0
|
作者
Mekonin, Tadelech Sisay [1 ]
Deressu, Tilahun Tesfaye [1 ]
机构
[1] Addis Ababa Univ, Dept Phys, POB 1176, Addis Ababa, Ethiopia
来源
关键词
Computed tomography scanner; Image quality parameter; CT dose index; Quality assurance phantom; PMMA phantom; Medical radiation dose; COEFFICIENTS; ATTENUATION;
D O I
10.1186/s43055-023-01038-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The goal of this study was to assess the radiation dose delivered accuracy and the acceptable image quality parameter from the 16-slice Philips CT scanner in order to evaluate the current methodology for quality controls of computed tomography systems. The measured volume computed tomography dose index was 101 mGy and the displayed volume computed tomography dose index was 10.2 mGy and the dose length product is 680 mGy*cm for head scan, and the measured volume computed tomography dose index was 6.1 mGy and the displayed volume computed tomography dose index was 6.3 mGy and the dose length product was 587 mGy*cm for body scan, respectively. The image quality parameters were 4.4 HU, 2.3 HU, and 10 HU for uniformity, contrast-to-noise ratio, and computed tomography number accuracy (CT number accuracy) for quality assurance phantom, respectively. We propose that discussions and collaboration regarding patient and particular equipment adjustments be coordinated among radiologists, medical imaging technologists, and medical physicists. This can increase image quality, reduce absorbed radiation, and improve hospital medical care.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Deep learning image reconstruction algorithm for abdominal multidetector CT at different tube voltages: assessment of image quality and radiation dose in a phantom study
    Park, Hye Joo
    Choi, Seo-Youn
    Lee, Ji Eun
    Lim, Sanghyeok
    Lee, Min Hee
    Yi, Boem Ha
    Cha, Jang Gyu
    Min, Ji Hye
    Lee, Bora
    Jung, Yunsub
    EUROPEAN RADIOLOGY, 2022, 32 (06) : 3974 - 3984
  • [42] Deep learning image reconstruction algorithm for abdominal multidetector CT at different tube voltages: assessment of image quality and radiation dose in a phantom study
    Hye Joo Park
    Seo-Youn Choi
    Ji Eun Lee
    Sanghyeok Lim
    Min Hee Lee
    Boem Ha Yi
    Jang Gyu Cha
    Ji Hye Min
    Bora Lee
    Yunsub Jung
    European Radiology, 2022, 32 : 3974 - 3984
  • [43] How to measure CT image quality: Variations in CT-numbers, uniformity and low contrast resolution for a CT quality assurance phantom
    Gulliksrud, Kristine
    Stokke, Caroline
    Martinsen, Anne Catrine Traegde
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (04): : 521 - 526
  • [44] The Image Quality and Radiation Dose of 100-kVp versus 120-kVp ECG-Gated 16-Slice CT Coronary Angiography
    Park, Eun-Ah
    Lee, Whal
    Kang, Jin-Hwa
    Yin, Yong Hu
    Chung, Jin Wook
    Park, Jae Hyung
    KOREAN JOURNAL OF RADIOLOGY, 2009, 10 (03) : 235 - 243
  • [45] Comparison of radiation dose and image quality of Siremobil-IsoC3D with a 16-slice spiral CT for diagnosis and intervention in the human pelvic bone
    Wieners, G
    Pech, M
    Beck, A
    König, B
    Erdmenger, U
    Stöckle, U
    Wust, P
    Felix, R
    Schröder, RJ
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2005, 177 (02): : 258 - 264
  • [46] Performance of 16-slice multidetector CT angiography of renal arteries at various kilovoltage settings in living kidney donors: Impact on the image quality and radiation dose
    Kalva, SP
    Sahani, DV
    Desai, H
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (04) : 24 - 25
  • [47] Effect of Tube Voltage and Radiation Dose on Image Quality in Pediatric Abdominal CT Using Deep Learning Reconstruction: A Phantom Study
    Kim, Daehong
    Jeon, Pil-Hyun
    Lee, Chang-Lae
    Chung, Myung-Ae
    SYMMETRY-BASEL, 2023, 15 (02):
  • [48] Feasibility of the Quantitative Assessment Method for CT Quality Control in Phantom Image Evaluation
    Lee, Ki Baek
    Nam, Ki Chang
    Jang, Ji Sung
    Kim, Ho Chul
    APPLIED SCIENCES-BASEL, 2021, 11 (08):
  • [49] Estimating Image Quality and Radiation Dose Reduction with In-Plane Bismuth Shielding for CT Examinations: Phantom Study
    Liao, Y. L.
    Tsai, H. Y.
    Tyan, Y. S.
    Cheng, K. Y.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [50] Six iterative reconstruction algorithms in brain CT: a phantom study on image quality at different radiation dose levels
    Love, A.
    Olsson, M-L
    Siemund, R.
    Stalhammar, F.
    Bjorkman-Burtscher, I. M.
    Soderberg, M.
    BRITISH JOURNAL OF RADIOLOGY, 2013, 86 (1031):