A novel and clinically useful weight-optimized dynamic conformal arc in stereotactic radiation therapy of non-small cell lung cancer: Dosimetric comparison of treatment plans with volumetric-modulated arc therapy

被引:1
|
作者
Saglam, Yucel [1 ,2 ]
Selek, Ugur [1 ,2 ,3 ]
Bolukbasi, Yasemin [1 ,2 ,3 ]
机构
[1] Koc Univ, Sch Med, Dept Radiat Oncol, Davutpasa Caddesi 4, TR-34010 Istanbul, Turkiye
[2] Amer Hosp Istanbul, UT MD Anderson Radiat Oncol Outreach Ctr, Istanbul, Turkiye
[3] Univ Texas MD Anderson Canc Ctr, Dept Radiat Oncol, Houston, TX USA
关键词
Non-small cell lung cancer; Volumetric arc therapy; Conformal radiotherapy; ABLATIVE RADIOTHERAPY; MOTION; INTERPLAY; MANAGEMENT; SBRT;
D O I
10.1016/j.radphyschem.2022.110623
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Purpose: This study constitutes a feasibility assessment of dynamic conformal arc (DCA) therapy as an alternative to volumetric-modulated arc therapy (VMAT) for stereotactic body radiation therapy (SBRT) of lung cancer with the free-breathing technique using four-dimensional computed tomography.Methods: A total of 25 patients who received 50 Gy in four fractions treated using VMAT technique having two partial coplanar arcs with 6 MV beams for non-small cell lung cancer (NSCLC) were included. Plans were re -planned using a novel and clinically technique of weight optimized based on dynamic conformal Arcs with two coplanar partial dynamic conformal arcs (WO-DCA). For the two partial arcs, MLC aperture around the PTV was automatically generated at different margins for both arcs and maintained dynamically around the target during arc rotation. Weight of the two arcs using optimization method was adjusted between the arcs to maximize tumor coverage and protect organs at risk (OAR). The clinical VMAT and WO-DCA plans were compared via the RTOG-0915 protocol for conformity and dose to the organs at risk (OAR). Additionally, delivery efficiency, quality assurance pass rate, monitor unit and beam treatment time were recorded.Results: The mean value of quality assurance (QA) pass rate 98.16 +/- 1.27 in WO-DCA and 92.87 +/- 1.56 in VMAT. The rate was higher in WO-DCA (p < 0.001 and t = 8.75). The values of beam-on time (BOT) and monitor units (MU) in the VMAT technique were 4.20 (3.45-4.95) and 3155 (2279-4867) and they were 3.10 (2.85-3.35) and 2167 (1702-2948) in WO-DCA. These values were significantly improved with WO-DCA (p < 0.001 and p < 0.001)Conclusions: As there is, no beam modulation through the target, WO-DCA plans could potentially minimize small-field dosimetry error without MLC interplay effects via respiratory motion and provide similar doses to OAR and the tumor while providing faster treatment delivery by significantly reducing MU and BOT in lung cancer for tumors of appropriate localization. Additionally, providing WO-DCA eliminate patient-specific VMAT quality assurance; potentially offering cost-effective, same day SBRT treatments.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Cardiac Toxicity in Intensity Modulated Radiation Therapy, Dynamic Conformal Arc Therapy, and Volumetric Modulated Arc Therapy of Lung Cancers
    Ming, X.
    Feng, Y.
    Zhang, Y.
    Zhou, L.
    Deng, J.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S666 - S667
  • [22] A Dosimetric Comparison of Volumetric-Modulated Arc Therapy to Intensity-Modulated Radiation Therapy in the Treatment of Locally Advanced Rectal Carcinoma
    Eldebawy E.
    Rashed Y.A.
    AlKhaldi M.
    Day E.
    [J]. Iranian Journal of Medical Physics, 2020, 17 (06) : 374 - 379
  • [23] Intensity-modulated radiotherapy and volumetric-modulated arc therapy have distinct clinical advantages in non-small cell lung cancer treatment
    Jun Zhang
    Xiao-Ling Yu
    Guo-Feng Zheng
    Fei Zhao
    [J]. Medical Oncology, 2015, 32
  • [24] Intensity-modulated radiotherapy and volumetric-modulated arc therapy have distinct clinical advantages in non-small cell lung cancer treatment
    Zhang, Jun
    Yu, Xiao-Ling
    Zheng, Guo-Feng
    Zhao, Fei
    [J]. MEDICAL ONCOLOGY, 2015, 32 (04)
  • [25] Dosimetric comparison of volumetric modulated arc therapy and intensity modulated radiation therapy for anal cancer
    Chiang, Bing-Hao
    Hibbitts, Kerry
    Ortega, Heather
    Herman, Terence
    Ahmad, Salahuddin
    [J]. JOURNAL OF RADIOTHERAPY IN PRACTICE, 2020, 19 (02) : 190 - 192
  • [26] Comparison of volumetric-modulated arc therapy and intensity-modulated radiation therapy prostate cancer plans accounting for cold spots
    Tran Thi Thao Nguyen
    Hidetaka Arimura
    Ryosuke Asamura
    Taka-aki Hirose
    Saiji Ohga
    Jun-ichi Fukunaga
    [J]. Radiological Physics and Technology, 2019, 12 : 137 - 148
  • [27] Comparison of volumetric-modulated arc therapy and intensity-modulated radiation therapy prostate cancer plans accounting for cold spots
    Tran Thi Thao Nguyen
    Arimura, Hidetaka
    Asamura, Ryosuke
    Hirose, Taka-aki
    Ohga, Saiji
    Fukunaga, Jun-ichi
    [J]. RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2019, 12 (02) : 137 - 148
  • [28] Comparison of the Dosimetric Planning Efficiency of Dynamic Conformal Arc and Volumetric Modulated Arc Therapy Techniques for Stereotactic Body Radiotherapy of Lung Cancer Using Internal Target Volume
    Saglam, Yucel
    [J]. JOURNAL OF CLINICAL PRACTICE AND RESEARCH, 2023, 45 (01): : 19 - 24
  • [29] Comparison of the Dosimetric Planning Efficiency of Dynamic Conformal Arc and Volumetric Modulated Arc Therapy Techniques for Stereotactic Body Radiotherapy of Lung Cancer Using Internal Target Volume
    Saglam, Yuecel
    [J]. ERCIYES MEDICAL JOURNAL, 2023, 45 (01) : 19 - 24
  • [30] Cardiac Toxicity in Dynamic Conformal Arc Therapy, Intensity-Modulated Radiation Therapy and Volumetric Modulated Arc Therapy of Lung Cancers
    Ming, X.
    Feng, Y.
    Zhang, Y.
    Zhou, L.
    Deng, J.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 236 - +